91.100.50 (Binders. Sealing materials) 标准查询与下载



共找到 596 条与 相关的标准,共 40

This practice for preparation of test panels greatly increases the likelihood of achieving reproducible results in subsequent testing.1.1 This practice covers a procedure for the preparation of accelerated and outdoor weathering test panels of bituminous coatings. It is considered suitable for the preparation of film thicknesses in the range from 0.25 to 2.54 mm (0.010 to 0.100 in.).1.2 The values stated in SI units are to be regarded as standard.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning-Mercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA''s website, http://www.epa.gov/mercury/faq.htm, for additional information. Users should be aware that selling mercury and/or mercury-containing products into your state may be prohibited by state law.)

Standard Practice for Preparation of Test Panels for Accelerated and Outdoor Weathering of Bituminous Coatings

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

4.1 This practice for preparation of test panels greatly increases the likelihood of achieving reproducible results in subsequent testing. 1.1 This practice covers a procedure for the preparation of accelerated and outdoor weathering test panels of bituminous coatings. It is considered suitable for the preparation of film thicknesses in the range from 0.25 to 2.54 mm [0.010 to 0.100 in.]. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Mercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA''s website, http://www.epa.gov/mercury/faq.htm, for additional information. Users should be aware that selling mercury or mercury-containing products, or both, into your state may be prohibited by state law.)

Standard Practice for Preparation of Test Panels for Accelerated and Outdoor Weathering of Bituminous Coatings

ICS
91.100.50 (Binders. Sealing materials)
CCS
E43
发布
2007
实施

1.1 This practice is a guide for removing specimens for built-up bituminous roof systems during application, but before the application of flood coating and top surfacing, for determining the approximate quantities of the components and the possible presence of moisture, or dry spots between plies, in the field. Components may consist of:1.1.1 Insulation, when part of the roof membrane system,1.1.2 Plies of roofing felt,1.1.3 Interply layers of bituminous material, and1.1.4 Top coating, if present, before any surfacing aggregate has been applied.1.2 This practice is applicable to both 914-mm (36-in.) and 1000-mm (39 3/8-in.) wide felt rolls. 1.3 The values stated in SI (metric) units are to be regarded as the standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Sampling and Analysis of Built-Up Roof Systems During Application

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

1.1 This specification covers asbestos-free asphalt roof cement suitable for trowel application to roofings and flashings.1.2 The following precautionary caveat pertains only to the test method portion, Section 8 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Asphalt Roof Cement, Asbestos-Free

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q11
发布
2007
实施

4.1 This practice for preparation of test panels greatly increases the likelihood of achieving reproducible results in subsequent testing. 1.1 This practice covers a procedure for the preparation of accelerated and outdoor weathering test panels of bituminous coatings. It is considered suitable for the preparation of film thicknesses in the range from 0.25 to 2.54 mm (0.010 to 0.100 in.). 1.2 The values stated in SI units are to be regarded as standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Mercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA's website, http://www.epa.gov/mercury/faq.htm, for additional information. Users should be aware that selling mercury and/or mercury-containing products into your state may be prohibited by state law.)

Standard Practice for Preparation of Test Panels for Accelerated and Outdoor Weathering of Bituminous Coatings

ICS
91.100.50 (Binders. Sealing materials)
CCS
E43
发布
2007
实施

5.1 This practice is for the sampling and analysis of existing built-up roof systems. For roofs under construction, use Practice D3617. 1.1 This practice is a guide for removing test specimens from existing built-up roofing systems in the field and for determining the approximate quantities of the components of that specimen (Note 1). Components determined may be: 1.1.1 Insulation components when they are part of the roof membrane system, 1.1.2 Plies of roofing felt, 1.1.3 Interply layers of bituminous material, 1.1.4 Top coating, and 1.1.5 Surfacing. Note 1—This procedure is for the investigation of existing roofs and is not intended for new construction inspection. 1.2 This practice is applicable to both 914-mm (36-in.) and 1000-mm (39 3/8-in.) wide felt rolls. 1.3 The values stated in SI (metric) units are to be regarded as standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary information, see 6.3.2.1.

Standard Practice for Sampling and Analysis of Existing Built-Up Roof Systems

ICS
91.100.50 (Binders. Sealing materials)
CCS
发布
2007
实施

1.1 This specification covers reinforced non-vulcanized polymeric sheet made from chlorosulfonated polyethylene (CSM) intended for use as a single-ply roof membrane exposed to the weather. The sheet shall be reinforced with fiber or fabric.1.1.1 The polymers used in these sheets have thermoplastic characteristics at time of installation. The chlorosulfonated polyethylene will vulcanize in place under ambient conditions.1.2 The tests and property limits used to characterize these sheets are minimum values.1.2.1 In-place roof systems design criteria such as fire resistance, field seaming strength, impact/puncture resistance, material compatibility, and uplift resistance, among others, are factors that must be considered, but are beyond the scope of this specification.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 The following precautionary caveat pertains to the test methods portion only, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Reinforced CSM (Chlorosulfonated Polyethylene) Sheet Used in Single-Ply Roof Membrane

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

1.1 This specification provides requirements for membrane-forming liquids suitable for use as curing compounds and sealers on freshly placed concrete and as sealers on hardened concrete. These membranes have special properties, such as, alkali resistance, acid resistance, adhesion-promoting qualities, and resistance to degradation by UV light.Note 1For liquid membrane-forming curing compounds specified primarily by their ability to retain water in newly placed concrete (and by drying time, and for white pigmented products, reflectance), see Specification C 309.1.2 The values stated in SI units are to be regarded as the standard. (Inch pound units are shown in parentheses).The following precautionary caveat pertains only to the test methods portion, Section , of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.3 This is a performance specification. The allowable composition of products covered by this specification is limited by various local, regional, and national regulations. Issues related to air quality (solvent emission), worker exposure, and other hazards are not addressed here. It is the responsibility of the producers and users of these materials to comply with pertinent regulations.Warning-Some VOC exempt solvents used to meet the regulations are extremely flammable with low auto ignition temperatures and rapid evaporation rates. Consult the manufacturer''s product information sheet for important application and safety information.

Standard Specification for Liquid Membrane-Forming Compounds Having Special Properties for Curing and Sealing Concrete

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q24
发布
2007
实施

1.1 This specification covers asbestos-free asphalt roof coatings of brushing or spraying consistency.1.2 The following precautionary caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Asphalt Roof Coatings8212;Asbestos-Free

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

1.1 This specification covers two types of coal-tar pitch suitable for use in the construction of built-up roofing, dampproofing, and membrane waterproofing systems. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Standard Specification for Coal-Tar Pitch Used in Roofing, Dampproofing, and Waterproofing

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

5.1 This test method provides a means of evaluating roof membranes, seams, and laps for resistance to water migration from standing water on the roof. This test method evaluates roof membranes when first applied and also after simulated deterioration caused by the ultraviolet energy of the sun. 1.1 This test method covers the determination of water migration resistance of roof membranes including built-up roof membranes, modified bitumen, and single ply roof membranes. The procedures were developed to determine the potential for leakage of water through the roof membranes resulting from a standing head of water and when pressurized with air from the underside. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Determining Water Migration Resistance Through Roof Membranes

ICS
91.100.50 (Binders. Sealing materials)
CCS
发布
2007
实施

The connection strength between geosynthetic reinforcement and segmental concrete block units is used in design of reinforced soil retaining walls. This test is used to determine the connection strength for the design of the connection system formed by segmental concrete block units and geosynthetic reinforcement layers in reinforced soil retaining walls. Performing a series of these connection tests at varying normal loads permits development of a relationship between connection strength and normal load. This relationship may be linear, bi-linear, or some other complex mathematical expression. This connection strength test is meant to be a performance test (laboratory or field), therefore, it should be conducted using full-scale system components. The conditions for the test are selected by the user and are not for routine testing. As a performance test on full-scale system components it accounts for some of the variables in construction procedures and materials tolerance normally present for these types of retaining wall systems.1.1 This test method is used to determine the connection properties between a layer of geosynthetic reinforcement and segmental concrete block units used in construction of reinforced soil retaining walls. The test is carried out under conditions determined by the user that reproduce the connection system at full-scale. The results of a series of tests are used to define a relationship between connection strength for a segmental unit-geosynthetic connection system and normal load.1.2 This is a performance test used to determine properties for design of retaining wall systems utilizing segmental concrete units and soil reinforcing geosynthetics, either geotextiles or geogrids. The test is performed on a full-scale construction of the connection and may be run in a laboratory or the field.1.3 The values stated in SI units are regarded as the standard. The values stated in inch-pound units are provided for information only.This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Determining Connection Strength Between Geosynthetic Reinforcement and Segmental Concrete Units (Modular Concrete Blocks)

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q72
发布
2007
实施

1.1 These test methods cover procedures for sampling and testing prefabricated, reinforced, polymer-modified bituminous sheet materials designed for single- or multiple-ply application in roofing and waterproofing membranes. These products may use various surfacing materials on one side.1.2 These test methods appear in the following order:1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Sampling and Testing Modified Bituminous Sheet Material

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

1.1 These test methods cover procedures for sampling and testing prefabricated, reinforced, polymer-modified bituminous sheet materials designed for single- or multiple-ply application in roofing and waterproofing membranes. These products may use various surfacing materials on one side.1.2 These test methods appear in the following order:SectionSampling3Conditioning4Thickness5Load Strain Properties6Tear Strength7Moisture Content8Water Absorption9Dimensional Stability10Low-Temperature Flexibility11Heat Conditioning12Accelerated Weathering13Granule Embedment14Compound Stability15Coating Thickness16Low Temperature Unrolling17Precision and Bias181.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Sampling and Testing Modified Bituminous Sheet Material

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

1.1 These test methods cover procedures for sampling and testing prefabricated, reinforced, polymer-modified bituminous sheet materials designed for single- or multiple-ply application in roofing and waterproofing membranes. These products may use various surfacing materials on one side.1.2 These test methods appear in the following order:1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Sampling and Testing Modified Bituminous Sheet Material

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

This practice is intended to measure air flow through materials used to fill joints found in building construction. This practice does not purport to establish all required criteria for the selection of an air barrier assembly. Therefore, the results should be used only for comparison purposes and should not be seen as the equivalent to field installed building systems.1.1 This practice is intended to determine the air leakage rate of aerosol foam sealants as measured in a standardized jig. This practice provides a procedure for preparing the test apparatus and further describes the application of aerosol foam sealant and other joint fillers to the apparatus prior to conducting Test Method E 283.1.2 This practice allows testing laboratories to quantify the air leakage rate of aerosol foam sealants or joint filling products using Test Method E 283 and reporting the data in L/(s m2) according to Practice E 29.1.3 This practice is used in conjunction with Test Method E 283. Although Test Method E 283 is a laboratory test method used with fenestration products, individuals interested in performing field air leakage tests on installed units should reference Test Method E 783 and AAMA 502.1.4 Aerosol foam sealants are used for a variety of end use applications generally intended to reduce air leakage in the building envelope.1.5 Insulating type materials also will be found suitable for evaluation with this practice. 1.6 There are no other known practices or test methods that specify the preparation of the assemblies used to determine the air leakage rate of gap filling sealants, dry preformed foams or insulations.1.7 The values given in SI units are the standard. The inch-pound units in parentheses are for information only.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Determining Air Leakage Rates of Aerosol Foam Sealants and Other Construction Joint Fill and Insulation Materials

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q27
发布
2007
实施

1.1 This specification covers asphalt roofing in shingle form, composed of glass felt or felts impregnated and coated on both sides with asphalt, and surfaced on the weather side with mineral granules. This specification is designed for the evaluation of products as manufactured. The test methods, physical requirements, and minimum masses are to be measured immediately after packaging or at a reasonable time, as agreed upon between buyer and seller, after manufacture and before installation. Physical and performance requirements after application and during in-service use of the products described herein are beyond the scope of this material specification.1.2 Shingles meeting this specification are intended to be applied with a headlap of not less than 51 mm (2 in.).1.3 The shingles shall be supplied with a factory-applied self-sealing adhesive or be designed to be locked together during installation of the shingles.1.4 The values stated in SI units are to be regarded as the standard.The following safety hazards caveat pertains only to the test method described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

1.1 This specification covers two types of coal-tar pitch suitable for use in the construction of built-up roofing, dampproofing, and membrane waterproofing systems.1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only

Standard Specification for Coal-Tar Pitch Used in Roofing, Dampproofing, and Waterproofing

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q17
发布
2007
实施

1.1 Structural sealant glazing, hereinafter referred to as SSG, is an application where a sealant not only can function as a barrier against the passage of air and water through a building envelope, but also primarily provides structural support and attachment of glazing or other components to a window, curtain wall, or other framing system.1.2 This guide provides information useful to design professionals, manufacturers, contractors, and others for the design and installation of a SSG system. This information is applicable only to this glazing method when used for a building wall that is not more than 15176; from vertical; however, limited information is included concerning a sloped SSG application.1.3 Only a silicone chemically curing sealant specifically formulated, tested, and marketed for structural sealant glazing is acceptable for a SSG system application.1.4 The committee with jurisdiction for this standard is not aware of any comparable standard published by other organizations.1.5 The calculations and values stated in SI units are to be regarded as the standard. Values in parenthesis and inch-pound units are for information only. SI units in this guide are in conformance with IEEE/ASTM SI 10.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Guide for Structural Sealant Glazing

ICS
91.100.50 (Binders. Sealing materials)
CCS
Q24
发布
2007
实施

1.1 This specification covers in-situ applied, single-pack, moisture-triggered, aliphatic polyurethanes intended to form an elastomeric single-ply membrane, once cured. The cured membrane may or may not contain a reinforcing material. 1.2 Single-pack, moisture-triggered, aliphatic polyurethanes are characterized by their ability to use moisture to trigger the curing process only. 1.3 The tests and property limits used to characterize the liquid material and cured membrane are values intended to ensure minimum quality. In-place roof system design criteria such as fire resistance, material compatibility, and uplift resistance, among others, are factors that shall be considered but are beyond the scope of this specification. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Liquid-Applied, Single-Pack, Moisture-Triggered, Aliphatic Polyurethane Roofing Membrane

ICS
91.100.50 (Binders. Sealing materials)
CCS
发布
2007
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved