91.120.99 有关建筑物防护的其他标准 标准查询与下载



共找到 79 条与 有关建筑物防护的其他标准 相关的标准,共 6

1.1 This practice describes methods for reducing radon entry into existing attached and detached residential buildings three stories or less in height. This practice is intended for use by trained, certified or licensed, or both, or otherwise qualified individuals. 1.2 These methods are based on radon mitigation techniques that have been effective in reducing radon levels in a wide range of residential buildings and soil conditions. These fan powered mitigation methods are listed in Appendix X1. More detailed information is contained in references cited throughout this practice. 1.3 This practice is intended to provide radon mitigation contractors with a uniform set of practices that will ensure a high degree of safety and the likelihood of success in retrofitting low rise residential buildings with radon mitigation systems. 1.4 The methods described in this practice apply to currently occupied or formerly occupied residential buildings, including buildings converted or being converted to residential use, as well as residential buildings changed or being changed by addition(s) or alteration(s), or both. The radon reduction activities performed on new dwellings, while under construction, before occupancy, and for up to one year after occupancy, are covered by Practice E1465. 1.5 This practice also is intended as a model set of practices, which can be adopted or modified by state and local jurisdictions, to fulfill objectives of their specific radon contractor certification or licensure programs. Radon mitigation performed in accordance with this practice is considered ordinary repair. 1.6 The methods addressed in this practice include the following categories of contractor activity: general practices, building investigation, systems design, systems installation, materials, monitors and labeling, post-mitigation testing, and documentation. 1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety hazards. 1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings

ICS
91.120.99
CCS
发布
2021-10-01
实施

本指南共分6章,主要技术内容包括:1 总则;2 术语;3 基本规定;4 减振施工;5沿线文物加固与监测防护;6异常与应急处置

Protection Guide for Tunnel Engineering Construction passing through cultural relics

ICS
91.120.99
CCS
E489
发布
2021-09-09
实施
2021-09-09

总则、术语、 基本规定、室内空气、水质与水系统、舒适、安全、健身、服务及提高与创新。

Healthy Building Evaluation Criteria

ICS
91.120.99
CCS
E4710
发布
2021-08-31
实施
2022-09-22

总则、术语、基本规定、性能要求、设计、施工、验收。

Application technical standard for external wall insulation system of vertical fiber rock wool composite board

ICS
91.120.99
CCS
E4710
发布
2021-08-12
实施
2022-09-22

Management of moisture in buildings. Code of practice

ICS
91.120.99
CCS
发布
2021-07-29
实施
2021-07-29

-

Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems

ICS
91.120.99
CCS
发布
2021-07-01
实施

Technical specifications for termite control in water conservancy projects

ICS
91.120.99
CCS
P 09
发布
2021-03-06
实施
2021-06-06

Thermosyphon foundations for buildings in permafrost regions

ICS
91.120.99
CCS
发布
2021-03-01
实施

总则; 术语; 基本规 定 ; 性能要求; 设计; 施工; 验收。

SDJK technical specification for the application of fire protection and thermal insulation system for building exterior walls

ICS
91.120.99
CCS
E486
发布
2020-07-23
实施
2022-09-22

本标准适用于新建、改建、扩建、装饰装修房屋及房屋附属设施的白蚁预防工程。

Technical regulations for house termite prevention engineering

ICS
91.120.99
CCS
P20
发布
2019-12-16
实施
2020-03-01

1.1 This practice has been prepared for use by the designer, specifier, builder, and the installer of radiant barrier systems (RBS) for use in commercial/industrial building construction not otherwise restricted from use. The scope is limited to instruction relative to the use and installation of RBS, including a surface(s) normally having an emittance of 0.1 or less, such as metallic foil or metallic foil deposits, mounted on substrates. Some examples that this practice is intended to address include: (1) low-emittance surfaces in vented building envelope cavities intended to retard radiant transfer across the airspace: (2) low-emittance surfaces at interior building surfaces intended to retard radiant transfer to, or from, building inhabitants; and (3) low-emittance surface at interior building surfaces intended to reduce radiant transfer to, or from, radiant heating or cooling systems. 1.2 This practice covers the installation process from preinstallation inspection through the post-installation procedure. It does not cover the production of the radiant barrier materials. (See Specification C1313.) 1.3 This practice is not intended to replace the manufacturer’s installation instructions but shall be used in conjunction with such instructions. This practice is not intended to supercede local, state, federal, or international codes. 1.4 This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for installation of radiant barrier materials. It also assumes that the installer understands the fundamentals of commercial/ industrial building construction that affect the installation of RBS. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Sections 5 and 7. 1.7 When the installation or use of radiant barrier materials, accessories, and systems has the potential to pose safety or health problems, the manufacturer shall provide the user appropriate current information regarding any known problems associated with the use of the product of the company and shall also specify protective measures. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Commercial/Industrial Building Construction

ICS
91.120.99
CCS
发布
2019-10-15
实施

1.1 This practice has been prepared for use by the designer, specifier, builder, and the installer of radiant barrier systems (RBS) for use in (multiand single-family) residential building construction, not otherwise restricted from use. The scope is limited to instructions relative to the use and installation of RBS, including a surface(s) normally having an emittance of 0.1 or less, such as metallic foil or metallic foil deposits, mounted on substrates. Some examples that this practice is intended to address include: (1) low-emittance surfaces in vented building envelope cavities intended to retard radiant transfer across the airspace: (2) low-emittance surfaces at interior building surfaces intended to retard radiant transfer to, or from, building inhabitants; and (3) low-emittance surface at interior building surfaces intended to reduce radiant transfer to, or from, radiant heating or cooling systems. 1.2 This practice covers the installation process from preinstallation inspection through the post-installation procedure. It does not cover the production of the radiant barrier materials. (See Specification C1313.) 1.3 This practice is not intended to replace the manufacturer’s installation instructions but shall be used in conjunction with such instructions. This practice is not intended to supercede local, state, federal, or international codes. 1.4 This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for installation of radiant barrier materials. It also assumes that the installer understands the fundamentals of residential building construction that affect the installation of RBS. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Sections 5 and 7. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction

ICS
91.120.99
CCS
发布
2019-06-01
实施

Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction

ICS
91.120.99
CCS
发布
2018-11-01
实施

3基本规定 3.1方案设计 3.2材料 3.3施工 3.4验收 4现场勘查和资料查阅 4.1现场勘查 4.2资料查阅 5 防腐蚀设计    5.1一般规定    5.2防腐涂料    5.3细部节点 6 防水设计 6.1一般规定 6.2防水材料 6.3细部节点 7 防腐蚀施工    7.1一般规定 7.2基层处理 7.3防腐施工 8 防水施工 8.1一般规定 8.2基层处理 8.3防水施工 9 质量验收  9.1验收    9.2主控项目    9.3一般项目

Technical regulations for metal roof maintenance engineering

ICS
91.120.99
CCS
E509
发布
2018-09-10
实施
2018-09-27

1.1 This specification covers requirements, test methods, materials, and marking for polyethylene (PE), open bottom, buried arch-shaped chambers of corrugated wall construction used for collection, detention, and retention of stormwater runoff. Applications include commercial, residential, agricultural, and highway drainage, including installation under parking lots and roadways. 1.2 Chambers are produced in arch shapes with dimensions based on chamber rise, chamber span, and wall stiffness. Chambers are manufactured with integral feet that provide base support. Chambers may include perforations to enhance water flow. Chambers must meet test requirements for arch stiffness, flattening, and accelerated weathering. 1.3 Analysis and experience have shown that the successful performance of this product depends upon the type and depth of bedding and backfill, and care in installation. This specification includes requirements for the manufacturer to provide chamber installation instructions to the purchaser. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 The following safety hazards caveat pertains only to the test method portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Polyethylene (PE) Corrugated Wall Stormwater Collection Chambers

ICS
91.120.99
CCS
发布
2018-02-15
实施

This National Standard of Canada (NSC) addresses system design and installation requirements for radon mitigation in existing low-rise residential buildings (see 3.37). This standard provides diagnostic methods, design and installation instructions, and acceptable materials and product specifications, to maximize the radon reduction capacity of the system. This standard is specific to radon gas emanating from soil gas sources. This standard does not address specific mitigation techniques for radon from other sources (see Annex C). The scope of this NSC may include but is not limited to provision of requirements, specifications, guidelines and characteristics that can be used consistently to ensure that materials, products, processes and services used in the radon mitigation of existing low-rise residential buildings are fit for their purposes. This standard is intended to support Canadian regulation and may be used to support operational compliance for radon certification/qualification programs or to assist in preventing deceptive practices in the marketplace. The testing and evaluation of a product against this standard may require the use of materials and/or equipment that could be hazardous. This document does not purport to address all the safety aspects associated with its use. Anyone using this standard has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any applicable regulatory requirements prior to its use.

Radon mitigation options for existing low-rise residential buildings

ICS
91.120.99
CCS
发布
2017-11-01
实施

Radon mitigation options for existing low-rise residential buildings

ICS
91.120.99
CCS
发布
2017-11-01
实施

Cette Norme nationale du Canada (NNC) traite des exigences de conception et d’installation des systèmes d’atténuation du radon dans les maisons et petits bâtiments existants (voir 3.37). Cette norme fournit les méthodes diagnostiques, les directives de conception et d’installation ainsi que les spécifications relatives aux matériaux et produits acceptables permettant de maximiser la capacité du système à réduire le radon. Cette norme concerne le radon provenant des gaz souterrains. Elle ne touche pas aux techniques d’atténuation du radon issu d’autres sources (voir l’annexe C). L’objet de la présente NNC peut comprendre, sans s’y limiter, des exigences, des spécifications, des directives et des caractéristiques pouvant être employées en permanence afin de s’assurer que les matériaux, les produits, les procédés et les services utilisés pour atténuer le radon dans les maisons et petits bâtiments existants sont adaptés à leur usage. Cette norme vise à soutenir la réglementation canadienne et pourrait servir à assurer la conformité des activités des programmes de certification ou d’homologation en matière de radon ou contribuer à prévenir les pratiques commerciales trompeuses. La mise à l’essai et l’évaluation d’un produit en regard de la présente norme peuvent nécessiter l’emploi de matériaux ou d’équipement susceptibles d’être dangereux. La présente norme n’entend pas traiter de tous les aspects liés à la sécurité de son utilisation. Il appartient à l’utilisateur de la norme de se renseigner auprès des autorités compétentes et d’adopter des pratiques de santé et de sécurité conformes aux règlements applicables avant de l’utiliser.

Radon Mitigation Measures in Existing Homes and Small Buildings

ICS
91.120.99
CCS
发布
2017-11-01
实施

1.1 These practices cover standardized techniques for locating air leakage sites in building envelopes and air barrier systems. 1.2 These practices offer a choice of means for determining the location of air leakage sites with each offering certain advantages for specific applications. 1.3 Some of the practices require a knowledge of infrared scanning, building and test chamber pressurization and depressurization, smoke and fog generation techniques, sound generation and detection, and tracer gas concentration measurement techniques. 1.4 The practices described are of a qualitative nature in determining the air leakage sites rather than determining quantitative leakage rates. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 6. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Barrier Systems

ICS
91.120.99
CCS
发布
2017-07-15
实施

总则、术语、基本规定、材料、设计、施工、质量验收

Technical specification for application of thermal insulation & waterproofing compact system based on cellular glass

ICS
91.120.99
CCS
E470
发布
2017-03-14
实施
2017-07-12



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号