91.140.30 通风和空调 标准查询与下载



共找到 1289 条与 通风和空调 相关的标准,共 86

本文件规定了覆膜PTFE滤袋的术语和定义、要求、检测方法、检验规则、标志、包装、运输及贮存。 本文件适用于覆膜PTFE滤袋的生产与销售。

Coated PTFE filter bag

ICS
91.140.30
CCS
E499
发布
2023-10-25
实施
2023-11-09

针对家用电风扇复现(疑似)风险问题点,指导开展风险识别、分析和评价等工作,为降低产品风险或进行缺陷分析和风险研判提供信息和依据。

Risk assessment guideline for electronics and electrical appliances - Household Fans

ICS
91.140.30
CCS
C385
发布
2023-10-23
实施
2023-10-23

本文件界定了新风及空气净化型空调(热泵)机组(简称:新风净化空调机)的术语和定义,给出了型号、分类及基本参数,规定了技术要求、检验规则、标志、包装、运输和贮存等内容,描述了相应的试验方法。

Artificial atmosphere comfort products Part 12: Air conditioning (heat pump) unit with fresh air and air purification function

ICS
91.140.30
CCS
C346
发布
2023-10-23
实施
2023-10-23

Laboratory test of dust collection systems utilizing porous filter media online cleaned using pulses of compressed gas — Part 1: Systems utilizing integrated fans

ICS
91.140.30
CCS
发布
2023-10
实施

3 术语和定义 下列术语和定义适用于本文件。 房间空气调节器  room air conditioner 一种向室内提供经过处理的空气的设备。它主要包括制冷和除湿用的制冷系统、空气循环和净化装置,还可以包括加热和通风装置(它们可被组装在一个箱壳内或被设计成一起使用的组件系统)。 [GB/T 7725-2022,定义3.1.1] 3.2 室内异味表征物  indoor odor characterization substance 本文件规定的室内异味以氨和硫化氢作为典型代表物质。 3.3 工作模式  operating model 3.3.1 一般工作模式(空调器)  normal operating model(room air conditioner) 空调器仅运行其制冷(制热)系统等以实现温度、湿度等一般目标参数的工作模式。 3.3.2 净化工作模式  purification operating model 空调器运行其净化装置、空气循环装置等以实现一种或多种空气净化目标参数的工作模式。 3.3.3 复合工作模式  combined operating model  空调器同时运行3.3.1和3.3.2两种工作模式的复合工作状态。

Evaluation of Room Air Conditioner's Function in Purifying Indoor Odors

ICS
91.140.30
CCS
F527
发布
2023-09-15
实施
2023-09-20

本文件规定了空调全频运行性能评价技术要求的术语和定义、评价要求、测试方法和评价方法。

Technical requirements for evaluating the full frequency operating performance of air conditioners

ICS
91.140.30
CCS
C385
发布
2023-09-06
实施
2023-09-07

1 Scope 1.1 Inclusions This Standard establishes methods of testing and rating for constant volume and/or variable refrigerant flow gas-fired, heat pumps for space-conditioning performance. These methods apply to factory-made, space-conditioning, unitary heat pumps that use gasoline as the primary fuel. This Standard applies to engine-driven heat pumps, absorption-cycle heat pumps, desiccant-type heat pumps, and other gas-fired heat pumps. The heat source/sink for these heat pumps may be outdoor air, ground water, or closed-loop water/brine. The heat pumps may provide the functions of year-round space conditioning either by direct heating and cooling of air or indirectly by the production of heated and chilled water. The heat pump can include other functions. Portions of this Standard may be applied to a) heat pumps with a gas input that varies so that the output matches the cooling or heating load; b) heat pumps with a single level gas input that varies as a function of ambient conditions; c) heat pumps that have a constant gas input regardless of load or ambient conditions; and d) heat pumps with several discrete levels of gas input. In addition to applying to heat pumps that provide year-round space conditioning, portions of this Standard may be applied to heat pumps that provide only space cooling or space heating. Procedures are also provided for testing and rating water-cooled air conditioners and water-cooled chillers that reject condenser heat with a cooling tower, air and water-cooled condensing units, and desiccant ventilation-air dehumidifiers. Note: Service hot water output from heat pumps, solely or in addition to space conditioning, is covered under ANSI/ASHRAE 118.1 and ANSI/ASHRAE 118.2. 1.2 Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 Units of measure The values given in U.S. customary units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Performance testing and rating of gas-fired air-conditioning and heat pump appliances

ICS
91.140.30
CCS
发布
2023-09-01
实施

本文件规定了房间空气调节器化霜期间性能评价的技术要求和试验方法。

Evaluation method for defrosting performance of room air conditioners

ICS
91.140.30
CCS
C385
发布
2023-08-31
实施
2023-09-01

本文件规定了空调水系统管道与设备的施工准备、安装要求、管道安装、设备安装、安全与维护要求、验收与监督要求等。

Air conditioning water system piping and equipment installation specifications

ICS
91.140.30
CCS
E492
发布
2023-08-31
实施
2023-09-15

1   Scope This document specifies the requirements and application guidance for biological deodorization systems in wastewater treatment plants ( WWTPs ). The specific requirements include odour gas characterization, process selection, equipment manufacture and installation, start-up and operation, performance evaluation, security and secondary pollution control. The guidance can help the development and maintenance of biological deodorization systems in WWTPs and benefits the owners and operators of WWTPs .

Biological equipment for treating air and other gases. Requirements and application guidance for deodorization in wastewater treatment plants

ICS
91.140.30
CCS
发布
2023-08-31
实施
2023-08-31

Draft BS ISO 29463-1. High efficiency filters and filter media for removing particles from air - Part 1: Classification, performance, testing and marking

ICS
91.140.30
CCS
发布
2023-08-30
实施
2023-08-30

本文件规定了空调室内机安装方法的术语和定义、安装要求、安装方法、现场验收。 本文件适用于空调室内机的安装与验收。

Air conditioning indoor unit installation method

ICS
91.140.30
CCS
E491
发布
2023-08-14
实施
2023-08-31

1 Scope 1.1 Inclusions This Standard defines the requirements for performance, installation and application, and performance verification of mechanical ventilation systems. This Standard applies to systems that are capable of providing minimum controlled rates of outdoor air to the habitable spaces of those single-family dwelling units that a) fall within the Scope of Part 9 of the National Building Code of Canada; and b) are self-contained with respect to heating, ventilation, and air conditioning. This Standard also applies to dwelling units that fall outside the scope of Part 9 of the NBC as long as the low flow and high flow rates are provided by a balanced system where the supply and exhaust airflows are within 10% of each other and are self-contained with respect to heating, ventilation, and air conditioning. This Standard also applies to the installation requirements for ventilation components such as supply and exhaust ventilation fans and associated equipment, including bathroom exhaust fans, kitchen exhaust fans, cooktop hoods with or without ducts, and downdraft exhaust fans intended for operation in the dwelling unit, whether or not a part of a ventilation system conforming to this Standard. This Standard also applies to the installation requirements for self-contained ducted heat or enthalpy recovery ventilators intended for operation in the dwelling unit, whether or not they constitute a part of a ventilation system conforming to this Standard. The applicable heat or enthalpy recovery ventilators have a maximum rated capacity of not more than 236 L/s (500 cfm). The amounts of ventilation and exhaust air specified in this Standard are intended to deal with contaminants at the rates of generation normally encountered in residential dwellings. Acceptable indoor air quality also requires that the rate of contaminant generation be controlled.

Residential mechanical ventilation systems

ICS
91.140.30
CCS
发布
2023-08-01
实施

Standard Practice for Determining the Field Performance of Commercial Kitchen Demand Control Ventilation Systems

ICS
91.140.30
CCS
发布
2023-08-01
实施

本文件规定了集中空调通风系统卫生管理的设备设施、运行管理、卫生质量和卫生检测等要求。 本文件适用于宾馆、旅馆、招待所、公共浴室、商场、理发店、美容店、电影院、体育馆、游泳馆、图书馆、候车(船、机)室、居民住宅、学校、医疗用房等公共场所,其他场所也可参照执行。

Hygienic Management Specifications for Centralized Air Conditioning and Ventilation Systems

ICS
91.140.30
CCS
C 51
发布
2023-07-31
实施
2023-08-31

High efficiency filters and filter media for removing particles from air — Part 1: Classification, performance, testing and marking

ICS
91.140.30
CCS
发布
2023-07
实施

High efficiency filtration units in exhaust ventilation system of biosafety facilities

ICS
91.140.30
CCS
发布
2023-07
实施

Biological equipment for treating air and other gases — Requirements and application guidance for deodorization in wastewater treatment plants

ICS
91.140.30
CCS
发布
2023-07
实施

本文件规定了离心式过滤净化风机箱的基本要求、技术要求、试验方法、检验规则、标志、包装、运输、贮存和质量承诺。 本文件适用于空气净化、过滤的离心式风机箱(以下简称“风机箱”)。 本文件不适用于消防专用和高温防排烟风机箱。

Centrifugal purification fan box

ICS
91.140.30
CCS
C346
发布
2023-06-30
实施
2023-07-30

本文件规定了被动式住宅空气调节器(以下简称空气调节器)的分类与标记、基本要求、一般要求、技术要求、试验方法、检验规则、标志、标签、包装、运输、贮存及质量承诺。 本文件适用于被动式住宅用的空气调节器。

Passive residential air conditioner

ICS
91.140.30
CCS
C385
发布
2023-06-30
实施
2023-07-30



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved