91.140.40 供气系统 标准查询与下载



共找到 351 条与 供气系统 相关的标准,共 24

The standard specifies requirements for the installation, exchange, relocation and removal of credit or prepayment diaphragm and ultrasonic gas meters with a maximum capacity not exceeding 6 m³/h. NOTE 1 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognized that each of these tasks can be performed by the same person. This part of BS 6400 is applicable to meter installations: a) supplied with 3rd family gases either: 1) from low pressure service pipework with a maximum operating pressure not exceeding 75 mbar and a design maximum incidental pressure of 350 mbar; or 2) from medium pressure service pipework with a maximum operating pressure exceeding 75 mbar but not exceeding 2 bar and a design maximum incidental pressure of 2.7 bar; b) only fitted downstream of the emergency control valve; c) that utilizes a meter regulator downstream of the emergency control valve; d) where all gas fittings subjected to medium pressure have been pre-assembled and where strength and gas tightness testing has been undertaken on the regulator assembly at the factory; e) where the operating pressure at the outlet of the meter is nominally 37 mbar. Installation pipework is specified in BS 5482-1 and LPGA Code of Practice 25 [14]. Service pipework (including the first emergency control valve) is specified in BS 5482-1 and the LPGA Code of Practice 22 [15] and LPGA Code of Practice 25 [14]. This standard does not cover pressure regulating installations installed in a service pipework upstream of the emergency control valve.

Specification for installation, exchange, relocation and removal of gas meters with a maximum capacity not exceeding 6 m3/h – Part 3: Low and medium pressure (3rd family gases)

ICS
91.140.40
CCS
Q82
发布
2007-11-31
实施
2007-12-31

1.1 This standard specifies general recommendations for the design, construction, testing, commissioning, operation and maintenance of installation pipework; pipework between the delivery point of the gas and the inlet connection to the gas appliance.This standard specifies common basic principles for gas installation pipework. Users of this European standard need to be aware that more detailed national standards and/or codes of practice may exist in the CEN member countries.This standard is intended to be applied in association with these national standards and/or codes of practice setting out the above mentioned basic principles. In the event of conflicts

Gas supply - Gas pipework for buildings - Maximum operating pressure less than or equal to 5 bar - Functional recommendations

ICS
91.140.40
CCS
发布
2007-11-05
实施
2007-11-05

1.1 This standard specifies general recommendations for the design, construction, testing, commissioning, operation and maintenance of installation pipework; pipework between the delivery point of the gas and the inlet connection to the gas appliance. This standard specifies common basic principles for gas installation pipework. Users of this European standard need to be aware that more detailed national standards and/or codes of practice may exist in the CEN member countries. This standard is intended to be applied in association with these national standards and/or codes of practice setting out the above mentioned basic principles. In the event of conflicts in terms of more restrictive requirements in national legislation/regulation with the requirements of this standard, national legislation/regulation takes precedence as illustrated in CEN/TR 13737. NOTE 1 CEN/TR 13737 contains: - clarification of relevant legislation/regulations applicable in a country; - if appropriate, more restrictive national requirements; - national contact point for the latest information. This standard applies to: -- gas installations in residential, commercial and public access building having a maximum operating pressure (MOP) less than or equal to 5 bar; -- industrial gas installations having a maximum operating pressure (MOP) less than or equal to 0,5 bar. NOTE 2 For industrial gas installations having a MOP above 0,5 bar, or installations having a MOP above 5 bar, see prEN 15001-1. This standard is applicable to new installation pipework as well as to replacements of, or extensions to, existing installation pipework. This standard does not contain detailed recommendations relating to the laying of buried pipework. ~,~ NOTE 3 For more information on buried pipework, see EN 12007-1, EN 12007-2 and EN 12007-3. NOTE 4 For more information on gas pressure regulating installations, see EN 12279. NOTE 5 For more information on gas metering systems, see EN 1776. 1.2 This standard is applicable to installation pipework supplied from gas distribution systems and from liquefied petroleum gases (LPG) storage vessels. Excluded are: -- single appliance LPG installations without fixed pipework, achieved by a flexible appliance connector from an adjacent LPG storage cylinder. -- LPG storage vessels. 1.3 In this standard the term 'gas' refers to combustible gases, which are gaseous at 15 ~C and I 013,25 mbar. These gases, odorized for safety reasons, are commonly referred to as manufactured gas, natural gas or liquefied petroleum gases (LPG). They are also referred to as first, second or third family gases (see EN 437). 0 In this standard, all pressures are gauge pressures, unless otherwise stated.

Gas supply - Gas pipework for buildings - Maximum operating pressure less than or equal to 5 bar - Functional recommendations; German version EN 1775:2007

ICS
91.140.40
CCS
Q82
发布
2007-10
实施

This European Standard specifies ranges, construction, performances, output characteristics and testing of rotary displacement gas meters (hereinafter referred to as RD meters or simply meters) for gas volume measurement. This European Standard applies to rotary displacement gas meters used to measure the volume jof fuel gases of the 1 th,2 nd and 3 rd gas families, the composition of which is specified in EN 437, at a maximum working pressure up to and including 16 bar over a gas temperature range of at least -10℃ to +40℃. This standard applies to meters that are instanlled in locations with vibration and shocks of low significance and in - closed locations (indoor or out door with protection as specified by the manufacturer) with or with non-condensing humidity or, if specified by the manufacturer, - open locations (outdoor without any covering) with consing humidity or with non-condensing ans in locations eith electromagnctic distrubances. Unless otherwise specified in this standard: - all pressures used are gauge; - all influence quantities, except the one under test, are kept relattively constant at their reference value.

Gas meters - Rotary displacement gas meters(includes Amendment A1:2006)English version of DIN EN 12480:2007-09

ICS
91.140.40
CCS
Q82
发布
2007-09
实施

Gas Supply Systems - Guidelines for Management systems for Gas Distribution Network; German version CEN/TS 15399:2007

ICS
91.140.40
CCS
Q82
发布
2007-09
实施

1.1 This standard specifies general recommendations for the design, construction, testing, commissioning, operation and maintenance of installation pipework; pipework between the delivery point of the gas and the inlet connection to the gas appliance. This standard specifies common basic principles for gas installation pipework. Users of this European standard need to be aware that more detailed national standards and/or codes of practice may exist in the CEN member countries. This standard is intended to be applied in association with these national standards and/or codes of practice setting out the above mentioned basic principles. In the event of conflicts in terms of more restrictive requirements in national legislation/regulation with the requirements of this standard, national legislation/regulation takes precedence as illustrated in CEN /TR 13737. NOTE 1 CEN/TR 13737 contains: - clarification of relevant legislation/regulations applicable in a country; - if appropriate, more restrictive national requirements; - national contact point for the latest information. This standard applies to: - gas installations in residential, commercial and public access building having a maximum operating pressure (MOP) less than or equal to 5 bar; - industrial gas installations having a maximum operating pressure (MOP) less than or equal to 0,5 bar. NOTE 2 For industrial gas installations having a MOP above 0,5 bar, or installations having a MOP above 5 bar, see prEN 15001-1. This standard is applicable to new installation pipework as well as to replacements of, or extensions to, existing installation pipework. This standard does not contain detailed recommendations relating to the laying of buried pipework. NOTE 3 For more information on buried pipework, see EN 12007-1, EN 12007-2 and EN 12007-3. NOTE 4 For more information on gas pressure regulating installations, see EN 12279. NOTE 5 For more information on gas metering systems, see EN 1776. 1.2 This standard is applicable to installation pipework supplied from gas distribution systems and from liquefied petroleum gases (LPG) storage vessels. Excluded are: - single appliance LPG installations without fixed pipework, achieved by a flexible appliance connector from an adjacent LPG storage cylinder. - LPG storage vessels. 1.3 In this standard the term 'gas' refers to combustible gases, which are gaseous at 15 °C and 1 013,25 mbar. These gases, odorized for safety reasons, are commonly referred to as manufactured gas, natural gas or liquefied petroleum gases (LPG). They are also referred to as first, second or third family gases (see EN 437). In this standard, all pressures are gauge pressures, unless otherwise stated.

Gas supply - Gas pipework for buildings - Maximum operating pressure less than or equal to 5 bar - Functional recommendations

ICS
91.140.40
CCS
Q82
发布
2007-08-31
实施
2007-08-31

本标准规定了城镇燃气用二甲醚的要求、试验方法、检验规则与标志、包装、运输和储存。 本标准适用于城镇居民、商业和工业企业用的城镇燃气用二甲醚。

Dimethyl ether for city gas

ICS
91.140.40
CCS
P47
发布
2007-08-21
实施
2008-01-01

This standard specifies general recommendations for the design, construction, testing, commissioning, operation and maintenance of installation pipework; pipework between the delivery point of the gas and the inlet connection to the gas appliance.This standard specifies common basic principles for gas installation pipework. Users of this European Standard need to be aware that more detailed national standards and/or codes of practice may exist in the CEN member countries.This standard is intended to be applied in association with these national standards and/or codes of practice setting out the above mentioned basic principles. In the event of conflicts in terms of more restrictive requirements in national legislation/regulation with the requirements of this standard, national legislation/regulation takes precedence as illustrated in CEN /TR 13737. NOTE 1 CEN/TR 13737 contains: clarification of relevant legislation/regulations applicable in a country; if appropriate, more restrictive national requirements; national contact point for the latest information.This standard applies to: gas installations in residential, commercial and public access building having a maximum operating pressure (MOP) less than or equal to 5 bar; industrial gas installations having a maximum operating pressure (MOP) less than or equal to 0,5 bar. NOTE 2 For industrial gas installations having a MOP above 0,5 bar, or installations having a MOP above 5 bar, see prEN 15001-1.This standard is applicable to new installation pipework as well as to replacements of, or extensions to, existing installation pipework.This standard does not contain detailed recommendations relating to the laying of buried pipework. NOTE 3 For more information on buried pipework, see EN 12007-1, EN 12007-2 and EN 12007-3. NOTE 4 For more information on gas pressure regulating installations, see EN 12279. NOTE 5 For more information on gas metering systems, see EN 1776.This standard is applicable to installation pipework supplied from gas distribution systems and from liquefied petroleum gases (LPG) storage vessels. Excluded are: single appliance LPG installations without fixed pipework, achieved by a flexible appliance connector from an adjacent LPG storage cylinder. LPG storage vessels. InThis standard the term 'gas' refers to combustible gases, which are gaseous at 15 ℃ and 1013,25 mbar. These gases, odorized for safety reasons, are commonly referred to as manufactured gas, natural gas or liquefied petroleum gases (LPG). They are also referred to as first, second or third family gases (see EN 437). InThis standard, all pressures are gauge pressures, unless otherwise stated.

Gas supply - Gas pipework for buildings - Maximum operating pressure less than or equal to 5 bar - Functional recommendations

ICS
91.140.40
CCS
发布
2007-08-01
实施

This European Standard specifies the requirements and tests for the construction, performance, safety and conformity of gas=volume electronic conversion devices associated to gas meters, used to measure volumes of fuel gases of the 1st and 2nd families according to EN 437. This European Standard is intended for type testing, the detailed relevant provisions of which are given in Annex A. Only three kinds of conversion are treated in this European Standard: - conversion as a function of temperature only (called T conversion); - conversion as a function of the pressure and of the temperature with constant compression factor ( called PT conversion); - conversion as a function of the pressure, the temperature and taking into account the compression factor (called PTZ conversion). This document is not relevant to temperature conversion integrated into gas meters which only indicate the converted volume. Gas-volume conversion devices consist of a calculator and a temperature transducer or a calculator, a temperature transducer and a pressure transducer locally installed. For application of this European Standard, a conversion device my be, as a choice of the manufacturer, considered as a complete instrument (Type 1) or made of separate elements (Type 2), according to the definitions given in 3.1.18.1 and 3.1.18.2. In this last case, the provisions concerning pressure transducers, temperature sensors and temperature transducers are given in Annexes B, C and D respectively. Any conversion device can provide an error curve correction for a gas meter. NOTE When rendering an account to an end user the readings from the conversion device can be used in conjunction with the readings from a gas meter conforming to EN 1359, EN 12480, or EN 12261, as appropriate, or to any other appropriate and relevant international standard for gas meters, without prejudice of national regulations.

Gas meters - Conversion devices - Part 1: Volume conversion (includes Amendment A1:2006); English version of DIN EN 12405-1:2007-08

ICS
91.140.40
CCS
Q82
发布
2007-08
实施
2007-08-01

This European Standard specifies the requirements of performance, the material and the test methods of corrugated flexible safety metallic hose assemblies for the connection of domestic appliances, in order to achieve save operation.The corrugated metal gas hose assemblies according to this European Standard are suitable for the connection of domestic appliances inside or outside a dwelling, using gas at a pressure lower than 0,5 bar.

Corrugated safety metal hose assemblies for the connection domestic appliance using gaseous fuels

ICS
91.140.40
CCS
发布
2007-07-30
实施
2007-07-30

This European Standard specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the second and/or third family, as given in EN 437, at maximum working pressures not exceeding 0,5 bar ) and maximum actual flow rates of up to 10 m3/h over a minimum ambient temperature range of -10 °C to +40 °C, and minimum gas temperature span of 40 K, for domestic applications. This European Standard applies to meters where the measuring element and

Ultrasonic domestic gas meters

ICS
91.140.40
CCS
发布
2007-07-30
实施
2007-07-30

This European Standard specifies the measuring conditions, requirements and tests for the construction, performance and safety of class 1,0 axial and radial turbine gas meters with mechanical indicating devices, herein after referred to as a meter(s), having in-line pipe connections for gas flow measurement. This European Standard applies to turbine gas meters used to measure the volume of fuel gases of the 1st and 2nd gas families, the composition of which is specified in EN 437, at maximum working pressures up to 420 bar, actual flow rates up to 25 000 m3/h over a gas temperature range of at least 40 K and for a climatic environmental temperature range of at least 50 K. This standard applies to meters that are installed in locations with vibration and shocks of Iow significance and in ~ closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity or, if specified by the manufacturer, ~ open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity and in locations with electromagnetic disturbances. Unless otherwise specified in this standard: ~ all pressures used are gauge; ~ all influence quantities, except the one under test, are kept relatively constant at their reference value. Clauses 1 to 7 and annex B are for design and type testing only, with the exception of 6.2.2.3, 6.2.3.3, 6.6.1.1.2 and 6.6.2.2.2. Annex C may be used to provide guidance on periodic tests during use. Clause 8 and annexes D and E are for each meter prior to dispatch. Annex A shall be used for both type and individual testing.

Gas meters - Turbine gas meters(includes Amendment A1:2006) ; English version of DIN EN 12261:2007-07

ICS
91.140.40
CCS
Q82
发布
2007-07
实施
2007-07-01

This British Standard specifies the construction and maintenance requirements of indirectly and directly driven single-stage centrifugal booster assemblies (hereafter referred to as machines), working on first, second or third family gas, having an outlet pressure of not greater than 150 mbar. This standard is not applicable to positive displacement gas and slide vane type compressors. This standard is also applicable to machines with outlet pressures not greater than 150 mbar used on landfill gases or biogases or gas/air mixtures, provided that any additional design and safety issues have been incorporated. Though applicable to single-stage machines only, this standard can be used as a basis for multi-stage machines where, in general, pressures higher than 150 mbar are achieved. NOTE All pressures are gauge pressures. All pressure tests are performed with air under ambient conditions.

The design and construction of gas boosters used in association with combustion equipment – Specification

ICS
91.140.40
CCS
Q82
发布
2007-06-29
实施
2007-06-29

This British Standard specifies the construction and maintenance requirements of indirectly and directly driven single-stage centrifugal booster assemblies (hereafter referred to as machines), working on first, second or third family gas, having an outlet pressure of not greater than 150 mbar. This standard is not applicable to positive displacement gas and slide vane type compressors. This standard is also applicable to machines with outlet pressures not greater than 150 mbar used on landfill gases or biogases or gas/air mixtures, provided that any additional design and safety issues have been incorporated. Though applicable to single-stage machines only, this standard can be used as a basis for multi-stage machines where, in general, pressures higher than 150 mbar are achieved.

The design and construction of gas boosters used in association with combustion equipment - Specification

ICS
91.140.40
CCS
Q82
发布
2007-06-29
实施
2007-06-29

Ultrasonic domestic gas meters

ICS
91.140.40
CCS
发布
2007-06-15
实施
2007-06-15

This European Standard specifies the requirements and tests for the construction, performance, safety and production of class 1,5 mechanical diaphragm gas meters (hereinafter referred to as meters) having co-axial single pipe, or two pipe connections, used to measure volumes of fuel gases of the 1st, 2nd and 3rd families according to EN 437, at maximum working pressures not exceeding 0,5 bar and maximum actual flow rates not exceeding 160 m3/h over a minimum ambient temperature range of-10 ℃ to +40 ℃ and a gas temperature range as specified by the manufacturer with a minimum span of 40 K. This standard applies to meters with and without built-in mechanical temperature conversion that are installed in locations with vibration and shocks of Iow significance and in -- closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity or, if specified by the manufacturer, -- open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity and in locations with electromagnetic disturbances. This standard does not cover meters with electronic indexes. Unless otherwise stated, all pressures given in this document are gauge pressure. Clauses 1 to 9 and Annexes B and F are for design and type testing only. NOTE Mechanical meters are not susceptible to electromagnetic interference and are therefore suitable for any electromagnetic environment.

Gas meters - Diaphragm meters(includes Amendment A1:2006); English version of DIN EN 1359:2007-06

ICS
91.140.40
CCS
Q82
发布
2007-06
实施

Ultrasonic domestic gas meters.

ICS
91.140.40
CCS
Q82
发布
2007-05-01
实施
2007-05-05

This European Standard specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the second and/or third family, as given in EN 437, at maximum working pressures not exceeding 0,5 bar 1) and maximum actual flow rates of up to 10 m3/h over a minimum ambient temperature range of -10 °C to +40 °C, and minimum gas temperature span of 40 K, for domestic applications. This European Standard applies to meters where the measuring element and the register(s) are enclosed in the same case. This European Standard applies to meters with and without built-in temperature conversion, that are installed in locations with vibration and shocks of low significance and in  closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity or, if specified by the manufacturer,  open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity and in locations with electromagnetic disturbances. Unless otherwise stated, all pressures given in this European Standard are gauge pressures. When more than one meter type is submitted for testing, then each meter type is required to be tested against this European Standard. Clauses 1 to 15 and Annex C are for design and type testing only. NOTE See Annex A for production requirements.

Ultrasonic domestic gas meters

ICS
91.140.40
CCS
N12
发布
2007-03-30
实施
2007-03-30

Safety Technical Specification for Gas of Buliding

ICS
91.140.40
CCS
P47
发布
2007-03-26
实施
2007-03-01

This European Standard specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the second and/or third family, as given in EN 437, at maximum working pressures not exceeding 0,5 bar 1) and maximum actual flow rates of up to 10 m3/h over a minimum ambient temperature range of -10 °C to +40 °C, and minimum gas temperature span of 40 K, for domestic applications. This European Standard applies to meters where the measuring element an

Ultrasonic domestic gas meters

ICS
91.140.40
CCS
发布
2007-01-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved