97.100.20 气体加热器 标准查询与下载



共找到 330 条与 气体加热器 相关的标准,共 22

Independent gas-fired convection heaters incorporating an auxiliary fan for burnes

ICS
97.100.20
CCS
Q83
发布
2013
实施
2015-01-01

Non-domestic mobile and portable direct fired air heaters with forced convection for liquefied petroleum gas. The general technical requirements and test methods

ICS
97.100.20
CCS
发布
2013
实施
2015-01-01

Non-domestic gas-fired forced convection air heaters without an auxiliary fan for burners for space heating not exceeding a net heat input of 300 kW. General technical requirements and test methods

ICS
97.100.20
CCS
Q83
发布
2013
实施
2015-01-01

Open fronted gas-fired independend space heaters

ICS
97.100.20
CCS
发布
2013
实施
2015-01-01

Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-Fired Duct Furnaces

ICS
97.100.20
CCS
J98
发布
2013
实施

This European Standard specifies the requirements and test methods for the construction, safety, marking and rational use of energy of open fronted gas-fired independent space heaters with and without a fan to assist with the transportation of flue gases, hereafter referred to as appliances. Although the fan may be mounted outdoors, this standard only covers appliances where the body of the appliance is indoors. This standard applies to types B 11AS, B11BS, B14AS, and B14BS (commonly referred to in this standard as type B1 appliances) open fronted gas-fired independent space heating appliances: that incorporate an atmospheric burner; that are connected directly to an open flue (see Figure 1), or to a device to evacuate the products of combustion (open-flued appliances); that have a nominal heat input not exceeding 20 kW (based on the net calorific value); that are delivered with the gas-carrying components, burner(s), combustion chamber and heat exchanger fully assembled. It does not apply to: closed-fronted appliances; decorative fuel effect appliances as specified in EN 509; catalytic combustion appliances; ducted-air appliances; appliances installed by means of a closure plate (see 3.3.3.3).

Open fronted gas-fired independent space heaters

ICS
97.100.20
CCS
Q83
发布
2013
实施
2013

Non-Recirculating Direct Gas-Fired Industrial Air Heaters

ICS
97.100.20
CCS
Q83
发布
2012-01-01
实施

This standard applies to decorative gas appliances for installation in solid-fuel burning fireplaces, which are constructed entirely of new, unused parts and materials: a. for use with natural gas; b. for use with propane; c. for use with natural and convertible for use with propane gas; d. for manufactured home (US only) or mobile home installation for use with natural and convertible for use with propane gas; and e. for manufactured home (US only) or mobile home installation for use with propane gas only.

Standard for Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces (same as CSA 2.26)

ICS
97.100.20
CCS
Q82
发布
2012-01-01
实施

Standard for Vented Gas Fireplace Heaters (same as CSA 2.33)

ICS
97.100.20
CCS
Q83
发布
2012
实施

Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters, and Gas-Fired Duct Furnaces (same as CSA 2.6b)

ICS
97.100.20
CCS
Q82
发布
2012
实施

Standard For Vented Gas Fireplaces (same as CSA 2.22)

ICS
97.100.20
CCS
Q83
发布
2012
实施

Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heaters

ICS
97.100.20
CCS
发布
2011-11-30
实施
2011-11-30

Gas engine driven heat pump air conditioners-General requirements

ICS
97.100.20
CCS
发布
2011-11-11
实施

이 표준은 실내를 쾌적하게 하는 공기 조화를 목적으로 해서, 도시가스 또는 액화 석유가스를

Gas engine driven heat pump air conditioners-General requirements

ICS
97.100.20
CCS
Q83
发布
2011-11-11
实施
2011-11-11

This European Standard specifies the additional requirements and test methods for gas-fired air heaters which are designed so that water vapour condenses from combustion products. On this subject, it extends the European Standards EN 778 and EN 1319 for domestic air heaters, and EN 1020 for non-domestic air heaters.This European Standard applies to gas-fired air heaters with or without a fan in the combustion circuit in one of the following constructional types:- an integral air heater with at least one condensing heat exchanger;- a non-condensing air heater with an integrated additional condensing heat exchanger;- a non-condensing air heater, with an integ

Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heaters

ICS
97.100.20
CCS
发布
2011-11-04
实施
2011-11-04

This European Standard specifies the additional requirements and test methods for gas-fired air heaters which are designed so that water vapour condenses from combustion products. On this subject, it extends the European Standards EN 778 and EN 1319 for domestic air heaters, and EN 1020 for non-domestic air heaters.

Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heaters; German version EN 1196:2011

ICS
97.100.20
CCS
Q83
发布
2011-11-01
实施

Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heaters.

ICS
97.100.20
CCS
Q83
发布
2011-10-01
实施
2011-10-28

This European Standard specifies the additional requirements and test methods for gas-fired air heaters which are designed so that water vapour condenses from combustion products. On this subject, it extends the European Standards EN 778 and EN 1319 for domestic air heaters, and EN 1020 for non-domestic air heaters. This European Standard applies to gas-fired air heaters with or without a fan in the combustion circuit in one of the following constructional types:  an integral air heater with at least one condensing heat exchanger;  a non-condensing air heater with an integrated additional condensing heat exchanger;  a non-condensing air heater, with an integrated additional condensing heat exchanger for the recovery of heat from combustion products and from ventilation air if appropriate. This European Standard covers type-testing only.

Domestic and non-domestic gas-fired air heaters. Supplementary requirements for condensing air heaters

ICS
97.100.20
CCS
Q83
发布
2011-08-31
实施
2011-08-31

This European Standard specifies the additional requirements and test methods for gas-fired air heaters which are designed so that water vapour condenses from combustion products. OnThis subject, it extends the European Standards EN 778 and EN 1319 for domestic air heaters, and EN 1020 for non-domestic air heaters.This European Standard applies to gas-fired air heaters with or without a fan in the combustion circuit in one of the following constructional types: an integral air heater with at least one condensing heat exchanger; a non-condensing air heater with an integrated additional condensing heat exchanger; a non-condensing air heater, with an integrated additional condensing heat exchanger for the recovery of heat from combustion products and from ventilation air if appropriate.This European Standard covers type-testing only.

Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heaters

ICS
97.100.20
CCS
发布
2011-08-01
实施

This British Standard specifies the installation requirements for direct and indirect gas-fired forced convection air heaters for space heating that are designed for commercial or industrial applications and to which The Gas Appliances (Safety) Regulations 1995 [1] apply. This British Standard applies to the installation and maintenance of appliances that are designed to utilize gases of Group H of the 2nd family (e.g. natural gas), gases of Group P of the 3rd family (e.g. propane) as well as gases of Group B of the 3rd family (e.g. butane) when supplied under the conditions of the third family pressure couple (see BS EN 437:2003+A1:2009). NOTE 1 This British Standard does not specifically cover LPG/air for which additional requirements might be necessary. This British Standard applies to the installation of direct gas-fired air heaters within the scope of BS EN 525:2009 and to indirect gas-fired forced convection air heaters within the scope of BS EN 621:2009, BS EN 1020:2009 and, where appropriate, BS EN 1196:1998. These standards cover air heaters having a net heat input not exceeding 300 kW. This standard also applies to the installation of direct gas-fired air heaters within the scope of BS 5990:2006 and to indirect gas-fired forced convection air heaters within the scope of BS 5991:1998. These standards cover air heaters having a gross heat input greater than 330 kW but not exceeding 2 MW (1.8 MW net). NOTE 2 For the purposes of this British Standard, installation includes design, inspection and commissioning. It is recognized that each of the tasks can be performed at the same time by different persons. NOTE 3 The ratio of gross to net heat input is approximately 1.11:1 for Group H (natural gas), 1.09:1 for Group P (propane) and 1.08:1 for Group B (butane). NOTE 4 The ventilation rates in cm2/kW of heat input given in this British Standard are based on the net calorific value. This British Standard also applies to air heaters designed to supply make-up air, door curtain heaters, transportable air heaters and heat exchange modules (i.e. air heaters without a main air movement fan) where such heat exchange modules are used in environmental non-process applications such as air handling units. It also covers installation of heaters in areas where petroleum or other flammable heavier-than-air vapours can be present (see 5.1.2). It does not include the safety requirements for installation where flammable dusts, toxic gases or flammable lighter-than-air gases might be present in significant quantities. NOTE 5 In such cases it is important that liaison takes place with the Health and Safety Executive. This British Standard does not apply to the installation of air heaters to which The Gas Appliances (Safety) Regulations 1995 apply, or that are designed for the sole use in domestic premises.

Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases)

ICS
97.100.20
CCS
Q83
发布
2011-07-31
实施
2011-07-31



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号