97.100.20 气体加热器 标准查询与下载



共找到 330 条与 气体加热器 相关的标准,共 22

This British Standard specifies the installation requirements for gas-fired overhead radiant heaters and systems for the environmental heating of premises other than domestic dwellings. This standard only applies to appliances falling within the scope of the Gas Appliances (Safety) Regulations 1995 [1]. It is applicable to the installation of heaters that are designed to use gases of group H of the 2nd family (e.g. natural gas), gases of group P of the 3rd family (e.g. propane) as well as gases of group B of the 3rd family (e.g. butane) (see BS EN 437+A1). NOTE 1 This standard does not specifically cover LPG/air for which additional requirements might be necessary. It is applicable to the installation of gas-fired overhead luminous radiant heaters conforming to BS EN 419-1, single burner gas-fired overhead radiant heaters conforming to BS EN 416-1 and multi-burner gas-fired overhead radiant tube heater systems conforming to BS EN 777-1, BS EN 777-2, BS EN 777-3 and BS EN 777-4. NOTE 2 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognized that each of these tasks may, at times, be performed by the same persons. NOTE 3 The heat inputs and ventilation rates in cm2/kW of heat input given in this standard are based on the net calorific value. It is not applicable to the installation of gas-fired overhead radiant heaters and systems: a) to which the Gas Appliances (Safety) Regulations 1995 [1] do not apply; b) that are designed for use in domestic premises; c) that are supplied with a heated fluid from a separate source; or d) that are portable or transportable.

Specification for installation and maintenance of gas-fired overhead radiant heaters for industrial and commercial heating (2nd and 3rd family gases)

ICS
97.100.20
CCS
Q82
发布
2011-06-30
实施
2011-06-30

Domestic heaters dedicated for liquefied petroleum gases, not connected to a chimney

ICS
97.100.20
CCS
发布
2011
实施
2013-01-01

Standard for Gas-Fired Tubular and Low Intensity Infrared Heaters (same as CSA 2.34)

ICS
97.100.20
CCS
Q82
发布
2011
实施

Gas burning space heaters for domestic use

ICS
97.100.20
CCS
Q82
发布
2010-11-22
实施

This Part of BS 5502 gives recommendations for the design, construction and use of agricultural storage tanks and reception pits for livestock slurry. NOTE Further sources of information are given in Appendix A. The titles of the publications referred to in this standard are listed on page 24.

Installation and maintenance of gas-fired ducted air heaters of rated heat input not exceeding 70 kW net (2nd and 3rd family gases). Specification

ICS
97.100.20
CCS
Q83
发布
2010-10-31
实施
2010-10-31

Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW; German version EN 1319:2009

ICS
97.100.20
CCS
Q83
发布
2010-10-01
实施

Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kW; German version EN 14829:2007, Corrigendum to DIN EN 14829:2007-11

ICS
97.100.20
CCS
Q82
发布
2010-07
实施

This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters having a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This includes appliances having forced draught burners.This European Standard applies to Type B12, B13, B14, B22, B23, B42, B43, B44, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with a heat input not exceeding 300 kW (based on net calorific value) intended for use in other than single unit residential dwellings. It also applies to appliances intended for outdoor installation. Provision of the heated air may be by means of ducting or may be directly into the heated space. For Type C62 and C63 appliances, this European Standard only applies when such appliances are intended for final installation in a similar manner to Type C3 appliances.

Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products; German version EN 1020:2009

ICS
97.100.20
CCS
Q83
发布
2010-05
实施

This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters not exceeding a net heat input of 300 kW with (an) atmospheric burner(s) and without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This European Standard applies to Type B, B, C and C, appliances intended for use in other than single unit residential dwellings. Provision of the heated air may be by means of ducting or may be directly into the heated space. This standard does not apply to: a) appliances intended for use in a single unit residential dwelling; b) appliances of the condensing type; c) appliances for outdoor installation; d) dual purpose air conditioning appliances (heating and cooling); e) appliances where the air is heated by an intermediate fluid; f) appliances with forced draught burners; g) appliances fitted with a manual or automatic means of adjusting the combustion air supply or the combustion products evacuation (including flue dampers); h) portable or transportable forced convection appliances; i) appliances having multiple heating units with a single draught diverter; j) appliances fitted with more than one flue outlet. k) appliances that are designed for continuous condensation within the flue system under normal operating conditions; l) appliances having combustion products evacuation ducts, POCEDs, that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals.

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products; German version EN 621:2009

ICS
97.100.20
CCS
Q83
发布
2010-04
实施
2010-04-01

Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW

ICS
97.100.20
CCS
发布
2010-03-31
实施
2010-03-31

Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products

ICS
97.100.20
CCS
发布
2010-03-31
实施
2010-03-31

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
发布
2010-03-31
实施
2010-03-31

This European Standard specifies the requirements and test methods for the safety and efficiency of domestic gas-fired air heaters with a fan to assist the transportation of combustion air and/or combustion products, hereafter referred to as appliances.This European Standard applies to Type B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with an input not exceeding 70 kW (net cv basis), intended primarily for use in single unit residential dwellings. Provision of the heated air may be by means of ducting.This standard does not app

Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW

ICS
97.100.20
CCS
发布
2010-03-12
实施
2010-03-12

Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
发布
2010-02-26
实施
2010-02-26

Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW.

ICS
97.100.20
CCS
Q83
发布
2010-02-01
实施
2010-02-13

This European Standard specifies the requirements and test methods for the safety and efficiency of nondomestic gas-fired air heaters having a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This includes appliances having forced draught burners. This European Standard applies to Type B12, B13, B14, B22, B23, B42, B43, B44, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with a heat input not exceeding 300 kW (based on net calorific value) intended for use in other than single unit residential dwellings. It also applies to appliances intended for outdoor installation. Provision of the heated air may be by means of ducting or may be directly into the heated space. For Type C62 and C63 appliances, this European Standard only applies when such appliances are intended for final installation in a similar manner to Type C3 appliances. This standard does not apply to: a) appliances intended for use in a single unit residential dwelling; b) appliances of the condensing type; c) appliances with atmospheric burners without a fan to assist the transportation of combustion air and/or flue gases; d) dual purpose air conditioning appliances (heating and cooling); e) appliances where the air is heated by an intermediate fluid; f) appliances fitted with manual or automatic flue dampers; g) portable or transportable forced convection appliances; h) appliances having multiple heating units with a single draught diverter; i) appliances fitted with more than one flue outlet; j) appliances that are designed for continuous condensation within the flue system under normal operating conditions; k) appliances having combustion products evacuation ducts, POCEDs, that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for appliances which are not type tested would need to be subject to further consideration.

Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products

ICS
97.100.20
CCS
Q82
发布
2010-01-31
实施
2010-01-31

This European Standard specifies the requirements and test methods for the safety and efficiency of domestic gas-fired air heaters with a fan to assist the transportation of combustion air and/or combustion products, hereafter referred to as appliances. This European Standard applies to Type B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with an input not exceeding 70 kW (net cv basis), intended primarily for use in single unit residential dwellings. Provision of the heated air may be by means of ducting. This standard does not apply to: a) appliances of the condensing type; b) appliances for outdoor installation; c) dual purpose air conditioning appliances (heating and cooling); d) appliances where the air is heated by an intermediate fluid; e) appliances with forced draught package burners or fully premixed burners; f) appliances fitted with a manual means of adjusting the combustion air supply or the evacuation of the combustion products; g) portable or transportable forced convection appliances; h) appliances having multiple heating units with a single draught diverter; i) appliances fitted with more than one flue outlet; j) Type C22, C23, C42, C43, C52 and C53 appliances; k) appliances that are designed for continuous condensation within the flue system under normal operating conditions; l) appliances having combustion products evacuation ducts, POCEDs, that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals.

Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW

ICS
97.100.20
CCS
Q83
发布
2010-01-31
实施
2010-01-31

This European Standard specifies the requirements and test methods for the safety and efficiency of nondomestic gas-fired air heaters not exceeding a net heat input of 300 kW with (an) atmospheric burner(s) and without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This European Standard applies to Type B11, B41, C11 and C31 appliances intended for use in other than single unit residential dwellings. Provision of the heated air may be by means of ducting or may be directly into the heated space. This standard does not apply to: a) appliances intended for use in a single unit residential dwelling; b) appliances of the condensing type; c) appliances for outdoor installation; d) dual purpose air conditioning appliances (heating and cooling); e) appliances where the air is heated by an intermediate fluid; f) appliances with forced draught burners; g) appliances fitted with a manual or automatic means of adjusting the combustion air supply or the combustion products evacuation (including flue dampers); h) portable or transportable forced convection appliances; i) appliances having multiple heating units with a single draught diverter; j) appliances fitted with more than one flue outlet; k) appliances that are designed for continuous condensation within the flue system under normal operating conditions; l) appliances having combustion products evacuation ducts, POCEDs, that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for appliances which are not type tested would need to be subject to further consideration.

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
Q83
发布
2010-01-31
实施
2010-01-31

Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not exceeding a net heat input of 70 kW

ICS
97.100.20
CCS
发布
2010-01-31
实施
2010-01-31

Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products

ICS
97.100.20
CCS
发布
2010-01-31
实施
2010-01-31