This European Standard specifies the requirements and test methods for the safety and efficiency of nondomestic gas-fired air heaters not exceeding a net heat input of 300 kW with (an) atmospheric burner(s) and without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This European Standard applies to Type B11, B41, C11 and C31 appliances intended for use in other than single unit residential dwellings. Provision of the heated air may be by means of ducting or may be directly into the heated space. This standard does not apply to: a) appliances intended for use in a single unit residential dwelling; b) appliances of the condensing type; c) appliances for outdoor installation; d) dual purpose air conditioning appliances (heating and cooling); e) appliances where the air is heated by an intermediate fluid; f) appliances with forced draught burners; g) appliances fitted with a manual or automatic means of adjusting the combustion air supply or the combustion products evacuation (including flue dampers); h) portable or transportable forced convection appliances; i) appliances having multiple heating units with a single draught diverter; j) appliances fitted with more than one flue outlet; k) appliances that are designed for continuous condensation within the flue system under normal operating conditions; l) appliances having combustion products evacuation ducts, POCEDs, that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for appliances which are not type tested would need to be subject to further consideration.

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
Q83
发布
2010-01-31
实施
2010-01-31

This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters not exceeding a net heat input of 300 kW with (an) atmospheric burner(s) and without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as """"appliances"""".This European Standard applies to Type B11, B41, C11 and C31 appliances intended for use in other than single unit residential dwellings. Provision of the heated air may be by means of ducting or may be directly into the heated space.This standard does not apply to:a) appliances intended for use in a single unit residential dwe

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
发布
2010-01-15
实施
2010-01-15

This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters having a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as """"appliances"""". This includes appliances having forced draught burners.This European Standard applies to Type B12, B13, B14, B22, B23, B42, B43, B44, B52, B53, C12, C13, C32, C33, C62 and C63 appliances with a heat input not exceeding 300 kW (based on net calorific value) intended for use in other than single unit residential dwellings. It also applies to appliances intended for outdoor installation. Provision of the h

Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products

ICS
97.100.20
CCS
发布
2010-01-15
实施
2010-01-15

This European Standard specifies the requirements and test methods for the safety and efficiency of domestic gas-fired air heaters with (an) atmospheric burner(s) and without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as """"appliances"""".This European Standard applies to Type B11, B11AS, B11BS, B41, B41AS, B41BS C11, C21, C31 and C41 appliances with an input not exceeding 70 kW (net cv-basis), intended primarily for use in single unit residential dwellings. Provision of the heated air may be by means of ducting.This European Standard does not apply to:a) appliances of the condensing type;b) appliances for

Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
发布
2010-01-11
实施
2010-01-11

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products.

ICS
97.100.20
CCS
Q83
发布
2010-01-01
实施
2010-01-30

Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products.

ICS
97.100.20
CCS
Q83
发布
2010-01-01
实施
2010-01-09

Details test and examination criteria for gas-fired high-intensity infrared heaters for use with natural, manufactured, mixed and liquefied petroleum (propane) gases and may be convertible for use with natural and LP-gases. Applies to heaters for installation in and heating of outdoor spaces or nonresidential indoor spaces where flammable gases or vapors are not generally present.

American National Standard/CSA Standard for Gas-Fired High Intensity Infrared Heaters, same as CSA 2.35a

ICS
97.100.20
CCS
Q82
发布
2010
实施

Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products.

ICS
97.100.20
CCS
Q83
发布
2009-12-01
实施
2009-12-18

Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW

ICS
97.100.20
CCS
发布
2009-11-30
实施
2009-11-30

This European Standard specifies the requirements and test methods for the safety and efficiency of domestic gas-fired air heaters with (an) atmospheric burner(s) and without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This European Standard applies to Type B11, B11AS, B11BS, B41, B41AS, B41BS C11, C21, C31 and C41 appliances with an input not exceeding 70 kW (net cv-basis), intended primarily for use in single unit residential dwellings. Provision of the heated air may be by means of ducting. This European Standard does not apply to: a) appliances of the condensing type; b) appliances for outdoor installation; c) dual purpose air conditioning appliances (heating and cooling); d) appliances where the air is heated by an intermediate fluid; e) appliances with forced draught burners; f) appliances fitted with a manual or automatic means of adjusting the combustion air supply or the combustion products evacuation (including flue dampers); g) portable or transportable forced convection appliances; h) appliances having multiple heating units with a single draught diverter; i) appliances fitted with more than one flue outlet; j) C21 and C41 appliances for 3rd family gases; NOTE For C41 appliances, see all requirements and test methods that are valid for C21 appliances, unless otherwise stated. k) appliances that are designed for continuous condensation within the flue system under normal operating conditions; l) appliances having Products Of Combustion Evacuation Ducts (POCED), that are non-metallic. This European Standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals.

Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 70 kW, without a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
Q83
发布
2009-11-30
实施
2009-11-30

This European Standard specifies the requirements and test methods for the safety of non-domestic direct gas fired forced convection air heaters having fully automatic control systems, hereafter referred to as "appliances". This European Standard applies to appliances of Type A2 and Type A3 with heat input based on the net calorific value of 300 kW or less fitted with integral burners intended for use other than in residential dwellings It also applies to appliances designed for outdoor installation. For indoor appliances provision of the heated air may be by means of ducting or may be directly into the heated space This standard does not apply to: a) appliances intended for use in residential dwellings; b) portable or transportable forced convection appliances; c) appliances fitted with gas boosters; d) appliances fitted with air/gas ratio controls; e) appliances which incorporate a main burner having more than one section under a common burner control, of which one or more sections may be extinguished whilst another section remains in operation. This European Standard is applicable to appliances which are intended to be type tested. NOTE Requirements for appliances which are not type tested would need to be subject to further consideration.

Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW; English version of DIN EN 525:2009-11

ICS
97.100.20
CCS
Q82
发布
2009-11
实施
2009-11-01

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube systems incorporating two or more burner units with each burner under the control of an automatic burner control system, and operated by a single fan providing a single flue outlet, called system H and referred to in the body of the text as the "system". This standard is applicable to Type B52 systems (see4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and the evacuation of the products of combustion is achieved by mechanical means. This standard is applicable only to such systems that have fully pre- mixed gas/air burners. This standard is not applicable to: a) systems designed for use in domestic dwellings; b) outdoor systems; c) systems of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference test gas); d) systems having a draught diverter; e) systems that are designed for continuous condensation within the flue system under normal operating conditions; f) systems having combustion products evacuation ducts that are non-metallic. This standard is applicable to systems which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for systems which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 4: System H - Safety; English version of DIN EN 777-4:2009-09

ICS
97.100.20
CCS
Q83
发布
2009-09
实施

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (called system F and referred to in the body of the text as the "system") with each burner unit under the control of an automatic burner control system. This standard is applicable to Type B52x and Type B53x systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: a) systems designed for use in domestic dwellings; b) outdoor systems; systems of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference test gas); d) systems having a draught diverter incorporated between the exhaust fan and the flue duct; e) systems having fully pre-mixed gas and air burners in which: either the gas and all the combustion air are brought together just before the level of the combustion zone; or the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone; systems that are designed for continuous condensation within the flue system under normal operating conditions; g) systems having combustion products evacuation ducts that are non-metallic. This standard is applicable to systems which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for systems which are not intended to be type tested would need to be subject to further consideration.

Multi-burner gas-fired overhead radiant tube heater systems for non domestic use - Part 3: System F - Safety; English version of DIN EN 777-3:2009-09

ICS
97.100.20
CCS
Q83
发布
2009-09
实施

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas fired overhead radiant tube heaters incorporating a single burner system under the control of an automatic burner control system, referred to in the body of the text as 'appliances'. This standard is applicable to Type A2, A3, B12, B13, B22, B23, B42, B43, B52, R53, O12, O13, 032 and 033 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means located upstream of the draught diverter, if provided. This standard is not applicable to: a) appliances designed for use in domestic dwelling; b) outdoor appliances; c) appliances of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference test gas); d) appliances having fully pre-mixed gas and air burners in which: 1) either the gas and all the combustion air are brought together just before the level of the combustion zone; or 2) the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone; e) appliances that are designed for continuous condensation within the flue system under normal operating conditions; f) appliances having combustion products evacuation ducts that are non-metallic. This standard is applicable to appliances which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for appliances which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Single burner gas-fired overhead radiant tube heaters for non-domestic use - Part 1: Safety; English version of DIN EN 416-1:2009-09

ICS
97.100.20
CCS
Q83
发布
2009-09
实施
2009-09-01

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (called system D and referred to in the body of the text as the "system") with each burner unit under the control of an automatic burner control system. This standard is applicable to Type B52 systems (see4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: a) systems designed for use in domestic dwelling; b) outdoor systems; c) systems of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference test gas); d) systems having a draught diverter; e) systems having fully pre-mixed gas and air burners in which: 1) either the gas and all the combustion air are brought together just before the level of the combustion zone; or 2) the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone; f) systems that are designed for continuous condensation within the flue system under normal operating conditions; g) systems having combustion products evacuation ducts that are non-metallic. This standard is applicable to systems which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for systems which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 1: System D - Safety; English version of DIN EN 777-1:2009-09

ICS
97.100.20
CCS
Q83
发布
2009-09
实施
2009-09-01

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (called system E and referred to in the body of the text as the 'system') with each burner unit under the control of an automatic burner control system. This standard is applicable to Type B52 and Type B53 systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: a) systems designed for use in domestic dwelling; b) outdoor systems; c) systems of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference test gas); d) systems having a draught diverter between the exhaust fan and the flue duct; e) systems having fully pre-mixed gas and air burners in which: 1) either the gas and all the combustion air are brought together just before the level of the combustion zone; or 2) the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone; f) systems that are designed for continuous condensation within the flue system under normal operating conditions; g) systems having combustion products evacuation ducts that are non-metallic. This standard is applicable to systems which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for systems which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 2: System E - Safety; English version of DIN EN 777-2:2009-09

ICS
97.100.20
CCS
Q83
发布
2009-09
实施
2009-09-01

This European Standard specifies the requirements and test methods for the safety of non-domestic direct gas-fired forced convection air heaters having fully automatic control systems, hereafter referred to as """"appliances"""". This European Standard applies to appliances of Type A2 and Type A3 with heat input based on the net calorific value of 300 kW or less fitted with integral burners intended for use other than in residential dwellings.It also applies to appliances designed for outdoor installation. For indoor appliances provision of the heated air may be by means of ducting or may be directly into the heated space.This standard does not apply to:a)

Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW

ICS
97.100.20
CCS
发布
2009-08-30
实施
2009-08-30

Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW.

ICS
97.100.20
CCS
Q83
发布
2009-08-01
实施
2009-08-22

This standard specifies the requirements and methods of test for the construction, safety, rational use of energy, classification and marking of 2nd and 3rd family gas-fired domestic radiant convector heating appliances not exceeding a nominal heat input of 15 kW based on the net calorific value and which incorporate a natural draught burner.

Specification for safety and rational use of energy of domestic gas appliances.Part 1:Radiant/convectors

ICS
97.100.20
CCS
Q82
发布
2009-07-31
实施
2009-07-31

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead luminous radiant heaters for environmental comfort, incorporating an atmospheric burner system referred to in the body of the text as "appliances". This European Standard is applicable to Type A1 appliances only (see 4.3). This European Standard is not applicable to: a) appliances designed for use in domestic dwellings; b) outdoor appliances; c) appliances of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference gas); d) appliances having fully pre-mixed gas and air burners in which: 1 ) either the gas and all the combustion air are brought together just before the level of the combustion zone; or 2) the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone; e) appliances in which the supply of combustion air and/or the removal of the products of combustion is achieved by integral mechanical means. This standard is applicable to appliances which are intended to be type tested. Requirements for appliances which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Non-domestic gas-fired overhead luminous radiant heaters - Part 1: Safety; English version of DIN EN 419-1:2009-07

ICS
97.100.20
CCS
Q83
发布
2009-07
实施
2009-07-01