97.100.20 气体加热器 标准查询与下载



共找到 330 条与 气体加热器 相关的标准,共 22

This European Standard specifies the requirements, the test methods and the marking of domestic flueless space heaters, including diffusive catalytic combustion heaters, having a nominal heat input (Hs), not exceeding 4,2 kW burning 3rd family gases at nominal operating pressures not exceeding 50 mbar, referred to in the text as 'appliances'. This European Standard is applicable to the following types of appliances: a) fixed heaters burning commercial butane and/or commercial propane; b) portable or mobile heaters burning either commercial butane, or, commercial butane and commercial propane including those that incorporate a LPG container installation comp

Specification for dedicated liquefied petroleum gas appliances - Domestic flueless space heaters (including diffusive catalytic combustion heaters)

ICS
97.100.20
CCS
发布
2008-03-07
实施
2008-03-07

This European Standard specifies the requirements, the test methods and the marking of domestic flueless space heaters, including diffusive catalytic combustion heaters, having a nominal heat input (Hs), not exceeding 4,2 kW burning 3rd family gases at nominal operating pressures not exceeding 50 mbar. referred to in the text as 'appliances'. This European Standard is applicable to the following types of appliances: a) fixed heaters burning commercial butane and/or commercial propane; b) portable or mobile heaters burning either commercial butane, or, commercial butane and commercial propane including those that incorporate a LPG container installation compartment for a transportable refillable liquefied petroleum LPG container. There are no specific thermal efficiency requirements appropriate to these types of appliance as: c) all the heat produced by the combustion process is released into the space to be heated; d) the requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas. It does not cover appliances incorporating electrically operated gas control systems. Annex A gives the details of the categories of appliances marketed in various countries. Requirements for appliances given in this standard assume that the supply of gas from the container will be governed by a pressure regulator having a maximum nominal outlet pressure of 50 mbar. This European Standard does not cover LPG containers for liquefied petroleum gas neither their associated regulator nor tubing and flexible hoses which shall comply with national requirements in force. This European Standard only covers type testing.

Specification for dedicated liquefied petroleum gas appliances - Domestic flueless space heaters (including diffusive catalytic combustion heaters) (includes Amendment A1:2007); English version of DIN EN 449:2008-03

ICS
97.100.20
CCS
Q83
发布
2008-03
实施
2008-03-01

Specification for dedicated liquefied petroleum gas appliances - Domestic flueless space heaters (including diffusive catalytic combustion heaters)

ICS
97.100.20
CCS
发布
2008-02-28
实施
2008-02-28

Details test and examination criteria for vented room heaters, direct vent wall furnaces, vented wall furnaces, and gravity and fan type floor furnaces for use with natural, manufactured and mixed gases, liquefied petroleum gases and LP gas-air mixtures.

Standard for Vented Gas-Fired Heating Appliances (same as CSA 2.32)

ICS
97.100.20
CCS
Q83
发布
2008
实施

Details test and examination criteria for direct gas-fired process air heaters of the recirculating or non-recirculating type, whose primary purpose is to provide process heating to non-occupied spaces within commercial and industrial buildings and may a

Direct Gas-Fired Process Air Heaters (same as CSA 3.19)

ICS
97.100.20
CCS
Q83
发布
2008
实施

American National Standard/CSA Group Standard for Gas-Fired Outdoor Infrared Heaters

ICS
97.100.20
CCS
Q82
发布
2008
实施

American National Standard/CSA Standard for Gas-Fired Infrared Patio Heaters (same as CSA 2.37a)

ICS
97.100.20
CCS
Q82
发布
2008
实施

This European standard specifies the design, safety and marking requirements and test methods for flueless patio heaters for outdoor or amply ventilated area use only.Although they are not covered by this standard, the requirements of this standard are applicable to appliances that may be used inside habitations which, in addition, shall have a heat input not exceeding 4,2 kW and comply with EN 449.These appliances are for use exclusively with gases of the third family as defined in Clause 4.This European standard applies to appliances that have a nominal heat input not exceeding 17 kW (based on the gross calorific value);. fixed or,. movable, including tho

Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use

ICS
97.100.20
CCS
发布
2007-12-07
实施
2007-12-07

Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kW

ICS
97.100.20
CCS
发布
2007-11-29
实施
2007-11-29

This document specifies, for the purpose of type examination, the requirements and test methods for construction, safety, marking and rational use of energy of 2nd and 3rd family gas-fired domestic flueless space heating appliances having a nominal input not exceeding 6 kW (based on net calorific value).It covers the following Type AAS fixed flueless heaters:NOTE These are type A appliances fitted with an atmosphere sensing device, with or without a fan.a) heaters with or without a catalytic converter;b) Category 1 appliances burning gases of the second family; c) Category 2 appliances burning gases of the second and third families.It does not cover i. Mobi

Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kW

ICS
97.100.20
CCS
发布
2007-11-05
实施
2007-11-05

This document specifies, for the purpose of type examination, the requirements and test methods for construction, safety, marking and rational use of energy of 2ne and 3rd family gas-fired domestic flueless space heating appliances having a nominal input not exceeding 6 kW (based on net calorific value). It covers the following Type AAS fixed flueless heaters: NOTE These are type A appliances fitted with an atmosphere sensing device, with or without a fan. a) heaters with or without a catalytic converter; b) Category 1 appliances burning gases of the second family; c) Category 2 appliances burning gases of the second and third families. It does not cover q i. Mobile heaters. ii. Category 1 appliances burning gases of the third family. iii. Portable flueless heaters. iv. Diffusive catalytic combustion heaters. There are no specific thermal efficiency requirements appropriate to these types of appliance as: -- All the heat produced by the combustion process is released into the space to be heated. -- The requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas. This standard is only applicable to appliances which are to be type tested. Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard.

Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kW; English version of DIN EN 14829:2007-11

ICS
97.100.20
CCS
Q83
发布
2007-11
实施
2007-11-01

Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use

ICS
97.100.20
CCS
发布
2007-10-15
实施
2007-10-15

This document specifies, for the purpose of type examination, the requirements and test methods for construction, safety, marking and rational use of energy of 2nd and 3rd family gas-fired domestic flueless space heating appliances having a nominal input not exceeding 6 kW (based on net calorific value). It covers the following Type AAS fixed flueless heaters: NOTE These are type A appliances fitted with an atmosphere sensing device, with or without a fan. a) heaters with or without a catalytic converter; b) Category 1 appliances burning gases of the second family; c) Category 2 appliances burning gases of the second and third families. It does not cover i. Mobile heaters. ii. Category 1 appliances burning gases of the third family. iii. Portable flueless heaters. iv. Diffusive catalytic combustion heaters. There are no specific thermal efficiency requirements appropriate to these types of appliance as:  All the heat produced by the combustion process is released into the space to be heated.  The requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas. This standard is only applicable to appliances which are to be type tested. Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with by this standard.

Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kW

ICS
97.100.20
CCS
Q83
发布
2007-09-28
实施
2007-09-28

Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use.

ICS
97.100.20
CCS
Q83
发布
2007-09-01
实施
2007-09-01

Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use.

ICS
97.100.20
CCS
Q83
发布
2007-09-01
实施

This European standard specifies the design, safety and marking requirements and test methods for flueless patio heaters for outdoor or amply ventilated area use only. Although they are not covered by this standard, the requirements of this standard are applicable to appliances that may be used inside habitations which, in addition, shall have a heat input not exceeding 4,2 kW and comply with EN 449. These appliances are for use exclusively with gases of the third family as defined in Clause 4. This European standard applies to appliances that have a nominal heat input not exceeding 17 kW (based on the gross calorific value); -- fixed or, -- movable, including those which comprise a housing for a transportable and rechargeable liquefied petroleum gas cylinder. This European standard does not apply to appliances equipped with a fan for either combustion or circulation of the convection air. This European standard does not cover LPG containers for liquefied petroleum gas, neither their associated regulator nor tubing and flexible hoses which shall comply with national requirements in force. This European standard does not lay down any specific requirements for the thermal efficiency of this type of appliances, but the requirements relating to combustion, which is a safety matter, ensure that the gas fuel will burn efficiently. However a method to measure the performance id described in informative Annex C. This standard does not apply to appliances covered by EN 416-1, EN 419-1, EN 416 and EN 521. This European standard only covers type testing. Items relating to quality assurance systems, production testing and particularly certificates of conformity of auxiliary equipment are not covered by this European standard.

Specification for dedicated liquefied petroleum gas appliances - Parasol patio heaters - Flueless radiant heaters for outdoor or amply ventilated area use (includes Amendment A1:2007) English version EN 14543:2007-09

ICS
97.100.20
CCS
Q83
发布
2007-09
实施

This document specifies, for the purpose of type examination, the requirements and test methods for construction, safety, marking and rational use of energy of 2 nd and 3 rd family gas-fired domestic flueless space heating appliances having a nominal input not exceeding 6 kW (based on net calorific value). It covers the following Type AAS fixed flueless heaters: NOTE These are type A appliances fitted with an atmosphere sensing device, with or without a fan. a) heaters with or without a catalytic converter; b) Category 1 appliances burning gases of the second family; c) Category 2 appliances burning gases of the second and third families. It does not cover i. Mobile heaters. ii. Category 1 appliances burning gases of the third family. iii. Portable flueless heaters. iv. Diffusive catalytic combustion heaters. There are no specific thermal efficiency requirements appropriate to these types of appliance as: All the heat produced by the combustion process is released into the space to be heated. The requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas.This standard is only applicable to appliances which are to be type tested. Matters related to quality assurance systems, tests during production and to certificates of conformity of auxiliary devices are not dealt with byThis standard.

Independent gas-fired flueless space heaters for nominal heat input not exceeding 6 kW

ICS
97.100.20
CCS
发布
2007-08-01
实施

This part of BS 5871 specifies installation and maintenance requirements for independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input not exceeding 6 kW burning 2nd and 3rd family gases for the purpose of heating rooms or internal spaces in domestic (see note 3) or commercial premises. Specifically, it covers: a) fixed appliances that satisfy all the requirements of BS EN 14829; b) fixed appliances that satisfy the combustion requirements of BS EN 14829; c) convector heaters of nominal heat input not exceeding 4.2 kW in the form of greenhouse heaters in respect of single appliance installations. NOTE 1 Appliances a) and b) are only intended as a secondary heat source (see Commentary and Recommendations on 4.2). The heat input and ventilation, fixing and gas supply for convector heaters in the form of greenhouse heaters are specified in 8.4, 9.4 and Clause 11, respectively. This part of BS 5871 covers the selection of a suitable appliance, room sizing and ventilation requirements and other measures necessary to ensure a safe installation. NOTE 2 Heat inputs in this document are based on net calorific value. [See also Commentary and Recommendations on Clause 5, item b).] NOTE 3 As well as normally constructed dwellings, domestic premises include any permanently sited caravans, holiday homes and residential park homes. (See IGE/UP/8 [9].) NOTE 4 Convector heaters in the form of greenhouse heaters are available in two forms, those which are freestanding and those which are intended to be fixed to a wall or floor. This standard is not applicable to: a) mobile and portable appliances conforming to BS EN 449; b) appliances in motor caravans and touring caravans; c) appliances in boats; d) installations in agricultural premises; or e) installations in transportable accommodation units. NOTE 5 For the maintenance of existing installations of 3rd family flueless appliances in boats, see PD 5482-3.

Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect appliances – Part 4: Independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input

ICS
97.100.20
CCS
Q83
发布
2007-07-31
实施
2007-07-31

Gas-fired insets for heating more than one room

ICS
97.100.20
CCS
发布
2007-05-31
实施
2007-05-31

This European Standard specifies the requirements and test methods for the construction, safety, marking and rational use of energy of gas-fired insets for heating more than one room that are intended to be built into a casing made from brickwork or similar material.This European Standard is intended to be used in conjunction with EN 613:2000.This European Standard is applicable to type B11BS insets burning gas: - that incorporate an atmospheric burner; - that are installed directly to an open flue or to a device to evacuate the products of combustion; - that have a nominal heat input not exceeding 20 kW (based on the net calorific value).In addition, this

Gas-fired insets for heating more than one room

ICS
97.100.20
CCS
发布
2007-05-31
实施
2007-05-31



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号