97.100.30 固体燃料加热器 标准查询与下载



共找到 153 条与 固体燃料加热器 相关的标准,共 11

Biomass clean air heater

ICS
97.100.30
CCS
J 75
发布
2023-05-26
实施
2023-11-26

BS EN 16510-2-7. Residential solid fuel burning appliances - Part 2-7. Combination appliances fired by wood logs and pellets

ICS
97.100.30
CCS
发布
2023-05-23
实施
2023-05-23

1   Scope The application of the calculations of this document enables a verification of the emission values carbon monoxide, nitrogen dioxide, organically bound carbon as well as dust and the energy efficiency . Complying with the calculations of this document results in emission values less or equal for carbon monoxide 1 500 mg/m n 3 (1 000 mg/MJ), nitrogen dioxide 225 mg/m n 3 (150 mg/MJ), organically bound carbon 120 mg/m n 3 (80 mg/MJ) and dust 90 mg/m n 3 (60 mg/MJ). If the calculations of this document are used in combination with suitable combustion chambers that prove lower emission values in a type test, these values are also considered to be complied with. There might be national or local regulations, which impose stricter legal emissions and/or efficiency requirements. This document specifies calculations for the dimensioning of Kachelgrundöfen/Putzgrundöfen (tiled/ mortared stoves ) based upon the required nominal heat output of the stove as declared by the producer. The Kachelgrundöfen/Putzgrundöfen (tiled/ mortared stoves ) are of individual one-off construction design. The document can be used for log wood fired Kachelgrundöfen/Putzgrundöfen (tiled/plastered stoves) that burn one fuel load per storage period with a maximum load between 10 kg and 40 kg (log wood with water content from 12 % to 20 %, thickness of 5 cm to 10 cm in diameter, length varies usually from 25 cm to 50 cm, and is oriented toward the combustion chamber dimensions) and a

One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves). Dimensioning

ICS
97.100.30
CCS
发布
2023-02-28
实施
2023-02-28

1   Scope This document is applicable to mechanical by wood pellets fed roomheaters, inset appliances and cookers up to 50 kW nominal heat output. The intended use of the appliances is space heating in residential buildings and can be cooking. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems. These appliances typically use auxiliary energy which is measured in this document as well. They can be operated with either natural draught or fan-assisted combustion air. NOTE A fan-assisted appliance does still operate under negative pressure in the flue gas system. These appliances burn wood pellets only as specified. They only operate with the firedoors closed. This document is not applicable to appliances: — with boiler intended for water systems having water temperatures above 110 °C and 3 bar; — with boiler intended for water systems having direct contact with sanitary hot water; — intended to be used with a pure horizontal exhaust (through the building wall); — with flue gas condensation in the appliance;

Residential solid fuel burning appliances - Mechanically by wood pellets fed roomheaters, inset appliances and cookers

ICS
97.100.30
CCS
发布
2023-01-31
实施
2023-01-31

Specifications for installation and acceptance of clean heating stove systems

ICS
97.100.30
CCS
Y 71
发布
2022-11-04
实施
2023-05-04

1.1 This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. These room heaters shall be drafted by forced or natural means. 1.2 Exhaust venting systems and associated externally mounted draft inducers are not evaluated by this specification unless they are part of an engineered system provided as part of the room heater. Parts specifically evaluated and determined to be acceptable for use with pellet fuel-burning room heaters are required to be specified in the room heater manufacturer’s instructions and are to be used in evaluating the room heater. 1.3 Pellet fuel-burning room heaters covered by this specification are intended for installation in accordance with the applicable requirements of NFPA 211 and in accordance with the applicable building and mechanical codes. 1.4 Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). See 24 CFR Part 3280. 1.5 The terms “product” or “room heater,” as used in this specification, refer to all pellet fuel-burning room heaters or any part thereof covered by the requirements of this specification, unless specifically noted otherwise. 1.6 No information provided in this specification is intended to prevent the use of other methods or devices, provided that sufficient technical data are submitted to the authority having jurisdiction to demonstrate that the proposed method or device is equivalent in quality, strength, fire endurance, effectiveness, durability, and safety to that prescribed in this specification. 1.7 The notes incorporated into this specification are not prescriptive requirements. They are given for clarification and informational purposes only. 1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.9 The following safety hazards caveat pertains only to the test methods portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Standard Specification for Room Heaters, Pellet Fuel-Burning Type

ICS
97.100.30
CCS
发布
2022-05-01
实施

Technical requirements for cleaning cooking and grilling stoves

ICS
97.100.30
CCS
Y 71
发布
2021-11-16
实施
2021-11-16

Test methods for cleaning cooking and grilling stoves

ICS
97.100.30
CCS
Y 71
发布
2021-11-16
实施
2021-11-16

One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) - Dimensioning

ICS
97.100.30
CCS
发布
2021-11-01
实施
2021-11-01

One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) - Dimensioning

ICS
97.100.30
CCS
发布
2021-10-00
实施

This DIN/TS is part of a series of technical specifications dealing with various devices for combustion air control and regulation, hereinafter referred to as ACA. An ACA in the sense of this DIN/TS takes over the functions of combustion air adjustment automatically over the enti

Residential solid fuel burning appliances - Combustion air devices - Control units for residential appliances - Part 3: Electrically powered, flue gas component controlled combustion air devices

ICS
97.100.30
CCS
发布
2021-09-00
实施

This DIN/TS is part of a series of technical specifications dealing with various devices for combustion air control and regulation, hereinafter referred to as ACA. The task of the ACA is to control or regulate the combustion in a reproducible and low-emission manner by adjusting

Residential solid fuel burning appliances - Combustion air devices - Control units for residential appliances - Part 4: Additional functions of combustion air devices

ICS
97.100.30
CCS
发布
2021-09-00
实施

This DIN/TS is part of a series of technical specifications dealing with various devices for combustion air control and regulation, hereinafter referred to as ACA. An ACA in the sense of this DIN/TS takes over the functions of combustion air adjustment automatically over the enti

Residential solid fuel burning appliances - Combustion air devices - Control units for residential appliances - Part 2: Mechanically controlled combustion air devices without auxiliary power

ICS
97.100.30
CCS
发布
2021-09-00
实施

1 Domaine d’application 1.1 La présente norme s’applique aux poêles à rayonnement, à convection ou à circulation forcée, alimentés manuellement en combustibles solides et destinés au chauffage domestique. Le combustible solide destiné à être utilisé avec chaque poêle est spécifié par le fabricant. 1.2 La présente norme s’applique aux : a) poêles pouvant être ventilés directement vers l’extérieur; et b) poêles utilisant des éléments de combustion catalytique (chambres de combustion). 1.3 La présente norme ne couvre pas les foyers ou les incinérateurs intégrés fabriqués en usine.

NORME POUR LES POÊLES À UTILISER AVEC DES COMBUSTIBLES SOLIDES

ICS
97.100.30
CCS
发布
2021-05-21
实施

Residential solid fuel burning appliances - Part 2-6: Mechanically by wood pellets fed roomheaters, inset appliances and cookers

ICS
97.100.30
CCS
发布
2021-05-15
实施
2021-05-15

Residential solid fuel burning appliances - Part 2-1: Roomheaters

ICS
97.100.30
CCS
发布
2021-05-15
实施
2021-05-15

Residential solid fuel burning appliances - Part 1: General requirements and test methods

ICS
97.100.30
CCS
发布
2021-05-15
实施
2021-05-15

Residential solid fuel burning appliances - Part 2-2: Inset appliances including open fires

ICS
97.100.30
CCS
发布
2021-05-15
实施
2021-05-15

STANDARD FOR SPACE HEATERS FOR USE WITH SOLID FUELS

ICS
97.100.30
CCS
发布
2021-05-13
实施

BS EN 16510-2-1. Residential solid fuel burning appliances - Part 2-1. Roomheaters

ICS
97.100.30
CCS
发布
2021-04-15
实施
2021-04-15



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号