The purpose of this European Standard is to provide the principles and guidance for the preparation of extended application documents for penetration sealing systems tested in accordance with EN 1366-3. The field of the extended application document is additional to the direct field of application given within EN 1366-3 and may be applied to or based on a single test, or a number of tests, which provide the relevant information for the formulation of an extended application. It should be noted that this European Standard provides general guidance on the likely effects of a change. It gives no guidance as to the magnitude, nor how this magnitude is evaluated. Composite pipes comprising both metallic and plastics components are not covered by this European Standard.

Extended applications of results from fire resistance tests for service installations - Part 3: Penetration seals; English version of DIN EN 15882-3:2009-07

ICS
CCS
C82
发布
2009-07
实施

This Part of EN 1366 specifies a method of test and criteria for the evaluation (including field of application rules) of the ability of a penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service. Penetration seals used to seal gaps around chimneys, air ventilation systems, fire rated ventilation ducts, fire rated service ducts, shafts and smoke extraction ducts are excluded from this standard except for mixed penetration seals. The fire resistance of those services itself cannot be assessed with the methods described in this standard. Supporting constructions are used in this standard to represent separating elements such as walls or floors. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice. This European Standard is used in conjunction with EN 1363-1. The purpose of this test described in this standard is to assess: a) the effect of such penetrations on the integrity and insulation performance of the separating element concerned; b) the integrity and insulation performance of the penetration seal; c) the insulation performance of the penetrating service or services, and where necessary, the integrity failure of a service. No information can be implied by the test concerning the influence of the inclusion of such penetrations and sealing systems on the Ioadbearing capacity of the separating element. It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes. Such phenomena are only to be noted in describing the general behaviour of test specimens during the test. This test is not intended to supply any information on the ability of the penetration seal to withstand stress caused by movements or displacements of the penetrating services. The risk of spread of fire downwards caused by burning material, which drips through a pipe downwards to floors below, cannot be assessed with this test. Explanatory notes to this test method are given in Annex H. All dimensions given without tolerances are nominal ones unless otherwise stated.

Fire resistance tests for service installations - Part 3: Penetration seals; English version of DIN EN 1366-3:2009-07

ICS
CCS
C82
发布
2009-07
实施

本标准规定了建设工程消防验收的内容、程序和技术要求,并提供了评定方法。 本标准适用于公安机关消防机构依法对新建、改建(含室内装修、用途变更)、扩建等建设工程竣工后实施的消防验收和竣工验收消防备案检查。

Criteria for acceptance inspection and assessment of building fire protection installation

ICS
13.220.20
CCS
C82
发布
2009-06-25
实施
2009-08-01

This European Standard specifies requirements for light fire storage units providing protection against fire. The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 P and LFS 60 P) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit. Requirements are also specified for the test specimen, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures. A scheme to classify the light fire storage units from the test results is also given (see Table 1).

Secure storage units - Classification and methods of test for resistance to fire - Light fire storage units

ICS
CCS
C82
发布
2009-05-31
实施
2009-05-31

This part specifies fire safety requirements for railway vehicle design to cover the objectives defined in CEN/TS 45545-1. The measures and requirements specified in this part of the Technical Specification aim to protect passengers and staff in railway vehicles in the event of a fire on board by minimizing the risk of a fire starting, delaying the fire development and controlling the spread of fire products through the vehicle, thus aiding evacuation. It is not within the scope of this Technical Specification to describe measures which ensure the preservation of the vehicles in the event of a fire. This part is valid for railway vehicles defined in CEN/TS 45545-1.

Railway applications — Fire protection on railway vehicles Part 4: Fire safety requirements for railway rolling stock design

ICS
13.220.20;45.060.01
CCS
C82
发布
2009-04-30
实施
2009-04-30

This part specifies requirements for flammable liquids and liquefied petroleum gas installations, e.g. for traction, auxiliary power units, heating or cooking, to cover the objectives defined in CEN/TS 45545-1. This part is not applicable to technical liquids themselves, e.g. hydraulic liquid, transformer oil, except where guidance is given as to dealing with spillages, leakage and spray generation. The measures and requirements specified in this Technical Specification aim to protect passengers and staff in railway vehicles by preventing a fire from occurring and spreading by leakage of flammable liquids or gases. It is not within the scope of this Technical Specification to describe measures for flammable gases, other than liquefied petroleum gases. It is not within the scope of this Technical Specification to describe measures that ensure the preservation of the vehicles in the event of a fire.

Railway applications — Fire protection on railway vehicles Part 7: Fire safety requirements for flammable liquid and flammable gas installations

ICS
13.220.20;45.060.01
CCS
C82
发布
2009-04-30
实施
2009-04-30

This part specifies the fire resistance requirements and testing methods for fire barriers for railway vehicles. The objective of the measures and requirements, specified in this part, is to protect passengers and staff in railway vehicles in the event of a developing fire on board. It is not within the scope of this part to describe measures that ensure the preservation of the vehicles in the event of a fire.

Railway applications — Fire protection on railway vehicles Part 3: Fire resistance requirements for fire barriers

ICS
13.220.20;45.060.01
CCS
C82
发布
2009-04-30
实施
2009-04-30

CEN/TS 45545 specifies: ? measures on railway vehicles for fire protection; ? verification of these measures. CEN/TS 45545 specifies prevention measures. The measures and requirements specified in CEN/TS 45545 are intended to protect passengers and staff in railway vehicles in the event of a fire on board. This protection of passenger and staff is essentially based on the ability of the rolling stock to allow for evacuation in safety, satisfying conditions (according to the objectives in Clause 4) in the frame of a guided transportation system which includes in particular vehicles, infrastructure and operation rules. The present Technical Specification describes the measures to be taken in the design of the vehicles in the context of the infrastructure within which they operate. It is not within the scope of CEN/TS 45545 to describe measures that ensure the preservation of the vehicles in the event of a fire. This Technical Specification is valid for railway vehicles as defined in 3.1. Freight transportation vehicles are not covered by CEN/TS 45545. This part of CEN/TS 45545 covers: ? principal definitions; ? operation categories; ? design categories; ? fire safety objectives; ? general requirements for fire protection measures and their evaluation of conformity.

Railway applications — Fire protection on railway vehicles Part 1: General

ICS
13.220.20;45.060.01
CCS
C82
发布
2009-04-30
实施
2009-04-30

This standard governs the materials, fabrication, installation, operation, testing, and maintenance of fire safety curtain systems used for proscenium opening protection.

Entertainment Technology - Fire Safety Curtain Systems

ICS
97.200.10
CCS
C82
发布
2009-04-21
实施

This part of IEC 60695 provides guidance for assessing and choosing candidate materials, components or sub-assemblies for making an end-product based upon preselection testing. It describes how preselection provides comparative fire hazard test methods to evaluate the performance of a test specimen and how preselection can be used in the selection of materials, parts, components and sub-assemblies during the design stage of an end-product. It further describes how standardized test methods may be used as one part in the decision making processes directed to minimize the fire hazards from electrotechnical equipment. It states that one should take into account the desired reaction to fire properties of the endproduct, and that one should consider the possible effects of environmental conditions on the behaviour of the end-product. This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.

Fire hazard testing - Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process - General guidelines

ICS
13.220.40;29.020
CCS
C82
发布
2009-03-31
实施
2009-03-31

Fire hazard of substances and materials. Materials, substance and fire protective means. Identification by thermal analysis methods

ICS
13.220.40;91.080.01
CCS
C82
发布
2009
实施
2009-05-01

Practice for Conducting an Interlaboratory Study to Determine the Precision of a Fire Test Method with Fewer than Six Participating Laboratories

ICS
13.220.01
CCS
C82
发布
2009
实施

This standard shall cover fire safety requirements for the installation of manufactured homes and manufactured home sites, including accessory buildings, structures, and communities.

Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities

ICS
13.200;91.040.30;91.140.01
CCS
C82
发布
2009
实施

Fire techniques. Means of fire automatics. The general technical requirements. Test methods

ICS
13.220.20
CCS
C82
发布
2009
实施
2009-05-01

This part of EN 1366 specifies a test method for determining the fire resistance of smoke extraction ducts that are used for single compartment applications only. In such applications, the smoke extraction system is only intended to function up to flashover (typically 600 °C). This method of test is only suitable for ducts constructed from non-combustible materials (euro class A1 and A2-s1, d0). It is applicable only to four sided and circular ducts. One, two and three sided ducts are not covered. This test has been designed to cover horizontal smoke extraction ducts intended for single compartment applications only. This test method of part 9 is applicable only to smoke extraction ducts that do not pass through into other fire compartments. It represents fire exposure of a developing fire (pre-flashover). For smoke extraction ducts that pass through into other compartments, the method of test described in EN 1366- 8 should be used. The smoke extraction duct is part of the smoke extraction system which also includes smoke control dampers and smoke extract fans. The method described in this test standard is complex and requires sophisticated instrumentation. It is not recommended therefore to try to test multiple assemblies in this test.

Fire resistance tests for service installations - Part 9: Single compartment smoke extraction ducts

ICS
13.220.50
CCS
C82
发布
2008-08-31
实施
2008-08-31

This part of EN 1366 specifies a test method for determining the fire resistance of smoke extraction ducts that are used for single compartment applications only. In such applications, the smoke extraction system is only intended to function up to flashover (typically 600 ~C). This method of test is only suitable for ducts constructed from non-combustible materials (euro class A1 and A2-sl, dO). It is applicable only to four sided and circular ducts. One, two and three sided ducts are not covered. This test has been designed to cover horizontal smoke extraction ducts intended for single compartment applications only. This test method of part 9 is applicable only to smoke extraction ducts that do not pass through into other fire compartments. It represents fire exposure of a developing fire (pre-flashover). For smoke extraction ducts that pass through into other compartments, the method of test described in EN 1366- 8 should be used. The smoke extraction duct is part of the smoke extraction system which also includes smoke control e dampers and smoke extract fans. The method described in this test standard is complex and requires sophisticated instrumentation. It is not recommended therefore to try to test multiple assemblies in this test.

Fire resistance tests for service installations - Part 9: Single compartment smoke extraction ducts; German version EN 1366-9:2008

ICS
13.220.50
CCS
C82
发布
2008-08
实施

Firefighting and assistance in or near electrical installations

ICS
13.220.10
CCS
C82
发布
2008-08
实施
2008-08-01

1.1 These requirements apply to factory built refractory liners intended for use in fuel-burning heating equipment, such as gas and/or oil-fired boilers, furnaces, and water heaters, to line the combustion chamber or serve as insulating material. 1.2 The combustion chamber liners are intended as a component of the fuel-burning end product equipment and are subject to the requirements of the applicable end product safety standard.

OUTLINE OF INVESTIGATION FOR REFRACTORY COMBUSTION CHAMBER LINERS Issue No. 1

ICS
CCS
C82
发布
2008-01-31
实施

Electrical apparatus for the detection of combustible gases in domestic premises. General requirements and control methods

ICS
13.220.01;13.320
CCS
C82
发布
2008
实施
2009-01-01

Test Methods E 119 and E 1529, and other standard fire resistance test methods specify that throughout exposures to fire and the hose stream, a constant superimposed axial load be applied to a load-bearing test specimen to simulate a maximum load condition. They specify that this superimposed load shall be as nearly as practicable the maximum load allowed by design under nationally recognized structural design criteria. For this practice, the nationally recognized structural design criteria is the National Design Specification for Wood Construction (NDS). Alternatively, the standard fire resistance test methods shall be conducted by applying an axial load that is less than the maximum allowable axial load as addressed by the NDS and this practice, but these tests shall be identified in the test report as being conducted under restricted load conditions. The superimposed axial load, as well as the superimposed axial load as a percentage of the maximum allowable axial design load as addressed by the NDS and this practice shall be included in the test report. This practice describes procedures for calculating the superimposed axial load to be applied in standard fire resistance tests of wood-frame wall assemblies. Statements in either the fire resistance test method standard or the nationally recognized structural design standard supercede any procedures described by this practice. The NDS shall be consulted to ensure calculations are in compliance with all applicable provisions of that document.1.1 This practice covers procedures for calculating the superimposed axial load required to be applied to load-bearing wood-frame walls throughout standard fire-resistance and fire and hose-stream tests. 1.2 The calculations determine the maximum load allowed by design for wood-frame wall assemblies under nationally recognized structural design criteria. 1.3 This practice is only applicable to those wood-frame assemblies for which the nationally recognized structural design criteria is the National Design Specification for Wood Construction (NDS). 1.4 The system of units to be used is that of the nationally recognized structural design criteria. For the NDS, the units are inch-pound. 1.5 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Resistance Tests