共找到 340 条与 防火技术 相关的标准,共 23

本标准适用于海南地区新建、扩建、改建的家庭旅馆的防火设计,已经投入使用的家庭旅馆按本标准执行。家庭旅馆的防火设计,除执行本标准外,尚应符合现行的有关国家标准、规范规定。本标准不适用于设在地下室、半地下室的家庭旅馆。

Family hotel fire technical regulations

ICS
13.220.01
CCS
C82
发布
2005-03-29
实施
2005-05-01

本标准规定了挡烟垂壁的术语和定义、分类、基本参数、标记、要求、试验方法、检验规则、标志、包装、运输、贮存等内容。 本标准适用于工业与民用建筑防烟分区中使用的活动式挡烟垂壁,固定式挡烟垂壁可参照执行。

Smoke curtains

ICS
13.220.50
CCS
C82
发布
2005-03-17
实施
2005-10-01

本标准规定了母线干线系统(母线槽)的阻燃、防火、耐火性能的试验装置、试验条件、试件要求、试验程序、判定条件和试验报告。 本标准适用于额定交流电压不大于1000V,频率为50Hz或60Hz的母线干线系统(母线槽)。

Flame-retardant、fire-proof、fire resistance specifications of testing method of busbar trunking system (busways)

ICS
13.220.50
CCS
C82
发布
2005-03-17
实施
2005-10-01

Fire resistance tests for service installations - Part 6: Raised access and hollow core floors; German version EN 1366-6:2004

ICS
13.220.50
CCS
C82
发布
2005-02
实施

This standard specifies a method for determining the fire resistance of: - balconies exposed to the fire from outside or inside; and - walkways exposed to the fire from outside or inside building.

Fire resistance tests for loadbearing elements - Part 5: Balconies and walkways; German version EN 1365-5:2004

ICS
13.220.50
CCS
C82
发布
2005-02
实施

This standard specifies a method for determining the fire resistance of stairs, with or without applied fire protection systems, and with or without cavities.

Fire resistance tests for loadbearing elements - Part 6: Stairs; German version EN 1365-6:2004

ICS
13.220.50
CCS
C82
发布
2005-02
实施

This procedure is particularly useful for screening fire debris samples to determine relative ignitable liquid concentrations and possible ignitable liquid class prior to extraction with other techniques. This practice is useful when volatile oxygenated products such as alcohols or lacquer thinners are suspected. This practice is the least sensitive of the sample preparation techniques and may not detect quantities of less than 10 μL of petroleum product. Because this separation takes place in a closed container, the sample remains in approximately the same condition in which it was submitted. Repeat and interlaboratory analyses are therefore possible. Due to variables in the debris sample condition prior to headspace sampling, complete reproducibility of chromatograms may be difficult to obtain. 4.5.1 To obtain greater reproducibility, use one of the separation procedures which results in a solution of the flammable or combustible liquid residue (see Practices E 1385, E 1386, E 1412, and E 1413.) High concentrations of highly volatile compounds may swamp the headspace, inhibiting the recovery of less volatile components.1.1 This practice covers the procedure for removing small quantities of ignitable liguid residue from samples of fire debris by sampling the headspace of the debris container. 1.2 Separation and concentration procedures are listed in the referenced documents. (See Practices E1385, E1386, E1412, and E1413.) 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Sampling of Headspace Vapors from Fire Debris Samples

ICS
13.220.99 (Other standards related to fire protect
CCS
C82
发布
2005
实施

本规程适用于新建、改建和扩建的工业和民用建筑中设置的1G-541灭火系统的设计、施工及验收。

Technical specification of inert gas IG-541 extinguishing system

ICS
13.220.99
CCS
C82
发布
2004-2-29
实施
2004-5-1

本标准适用于工业和民用建筑中消防设施的检验,不适用于生产和贮存火药、炸药、弹药、火工品等爆炸危险场所的消防设施检验。

Specification for builing fire service test in Autonomous Region Inner Mongolia

ICS
13.220.99
CCS
C82
发布
2004-2-29
实施
2004-5-1

This document is applicable to aluminium tubes. It describes the kind and position of tactile warnings of danger according to EN ISO 11683 in relation to the diameters of tubes.

Packaging - Collapsible aluminium tubes - Tactile warnings of danger; German version EN 14391:2004

ICS
11.180.30;55.120
CCS
C82
发布
2004-12
实施

Gives recommendations for the planning, installation and servicing of mechanical equipment for the actuation of gaseous fire extinguishing systems.

Code of practice for the operation of fire protection measures Part 2: Mechanical actuation of gaseous total flooding and local application extinguishing systems

ICS
13.220.20
CCS
C82
发布
2004-11-25
实施

Provides recommendations for the planning, installation and servicing of electrical equipment for the actuation of gaseous total flooding fire extinguishing systems for use in a temperate climate.

Code of practice for the operation of fire protection measures Part 1: Electrical actuation of gaseous total flooding extinguishing systems

ICS
13.220.20
CCS
C82
发布
2004-11-25
实施

This Part of EN 1365 specifies a method for determining the fire resistance, in respect with loadbearing capacity and with no separating function, of: - balconies exposed to the fire from either outside or inside the building; and - walkways exposed to the fire from either outside or inside the building. This standard is used in conjunction with EN 1363-1.

Fire resistance tests for loadbearing elements - Balconies and walkways

ICS
13.220.50
CCS
C82
发布
2004-11-18
实施
2004-11-18

This Part of EN 1365 specifies a method for determining the fire resistance of stairs, with or without applied fire protection systems in respect of loadbearing capacity and with no separating function. This document is used in conjunction with EN 1363-1.

Fire resistance tests for loadbearing elements - Stairs

ICS
13.220.50
CCS
C82
发布
2004-11-18
实施
2004-11-18

This Part of EN 1366 specifies a method for determining the fire resistance of raised access floors and hollow floors when subjected to a fire from within the plenum beneath the floor. The fire exposure applied to the test specimen may be either: a) standard time temperature curve; b) 'reduced' time temperature curve which follows the standard time/temperature curve only up to 500 ℃. After this temperature has been reached the temperature within the furnace is maintained at 500 ℃. This document does not determine the fire resistance of the sub-floor on which the raised or hollow floor is constructed; this is given in EN 1365-2.

Fire resistance tests for service installations - Raised access and hollow core floors

ICS
13.220.50
CCS
C82
发布
2004-11-18
实施
2004-11-18

Fire resistance tests for service installations - Part 8: Smoke extraction ducts; German version EN 1366-8:2004

ICS
13.220.50
CCS
C82
发布
2004-10
实施

This document specifies a method of test and criteria for the evaluation of the ability of a penetration sealing system to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service. Excluded are chimneys, air ventilation systems, fire rated ventilation ducts, fire rated service ducts, shafts and smoke extraction ducts. Supporting constructions are used in this document to represent separating elements such as walls or floors. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice. This document is used in conjunction with EN 1363-1. The purpose of this test described in this document is to assess: a) the effect of such penetrations on the integrity and insulation performance of the separating element concerned; b) the integrity and insulation performance of the penetration sealing system; c) the insulation performance of the penetrating service or services, and where necessary, the integrity failure of a service. No information can be implied by the test concerning the influence of the inclusion of such penetrations and sealing systems on the loadbearing capacity of the separating element. It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes. Such phenomena should only be noted in describing the general behaviour of test specimens during the test. This test does not supply any information on the ability of the penetration sealing system to withstand stress caused by movements or displacements of the penetrating services. Explanatory notes to this test method are given in Annex A.

Fire resistance tests for service installations - Penetration seals

ICS
CCS
C82
发布
2004-09-08
实施
2004-09-08

This document is one of a series of standards applicable to flexible sheets for waterproofing of concrete bridge decks and other concrete surfaces trafficable by vehicles. This document specifies a test method for the evaluation of the shear strength properties of the waterproofing sheet system applied to a concrete surface and with an asphalt layer.

Flexible sheets for waterproofing-Waterproofing of concrete bridge decks and other concrete surfaces trafficable by vehicles-Determination of shear strength

ICS
CCS
C82
发布
2004-09
实施

This part of EN 1366 specifies a method for determining the fire resistance of conveyor systems shutter assemblies designed for installation within openings incorporated in vertical and/or horizontal separating elements, including the necessary sealing measures, if the conveyor systems shutters are penetrated by parts of the conveyor tracks, by electrical cables or by pneumatic pipes.#,,#

Fire resistance tests for service installations - Part 7: Conveyor systems and their closures; German version EN 1366-7:2004

ICS
13.220.50
CCS
C82
发布
2004-09
实施

This Part of this document specifies a test method for determining the fire resistance of smoke extraction ducts. It is applicable only to smoke extraction ducts that pass through another fire compartment from the fire compartment to be extracted in case of fire. It represents fire exposure of a fully developed fire. This method of test is only applicable to fire resisting ducts that have passed the test for the appropriate period to EN 1366-1 (ducts A and B). For duct A, it is a requirement for fire resisting smoke extraction ducts that the document under pressure of 300 Pa, as given in EN 1366-1 is increased to 500 Pa when testing to EN 1366-1. For the purposes of the test described in this document, the duct is referred to as duct C. This test has been designed to cover both vertical and horizontal smoke extraction ducts. However, provided both horizontal and vertical tests have been carried out to EN 1366-1 on the specific system, a vertical system need not be evaluated to this method provided it has been tested in a horizontal orientation to this method. However, if the system in practice is only to be used for vertical applications in smoke extraction systems, then it will need to be tested in a vertical orientation to this method. This method of test is only suitable for ducts constructed from non-combustible materials (Euroclass A1 and A2). It is applicable only to four sided ducts; one, two and three sided ducts are not covered.

Fire resistance tests for service installations - Smoke extraction ducts

ICS
13.220.50
CCS
C82
发布
2004-08-04
实施
2004-08-04