K72 一般灯具 标准查询与下载



共找到 737 条与 一般灯具 相关的标准,共 50

Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety

ICS
29.140.01
CCS
K72
发布
2009-08
实施

This part of IEC 60598 applies to luminaires for cold cathode tubular discharge lamps and similar equipment, operating on a no-load rated output voltage over 1 000 V but not exceeding 10 000 V, mainly used for general lighting, for indoor or outdoor applications and for supply voltages up to 1 000 V. It covers luminaires incorporating luminous-discharge tubes and supply units, of fixed or portable type, supplied by high, mains or ELV voltages by transformers, inverters or converters. This standard does not cover luminaires for luminous-discharge tubes operating at rated voltages not exceeding 1 000 V (pre-heated cathodes), for which reference is made to the relevant part 2 of IEC 60598, and luminous discharge tube luminaires to be assembled in site as an electrical lighting system, for which regional wiring rules apply. This standard is read in conjunction with those sections of Part 1 to which reference is made.

Luminaires - Part 2-14:Particular requirements - Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment

ICS
29.140.40
CCS
K72
发布
2009-07-31
实施
2009-07-31

Specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltage up to 1000 V. Also covers classification, marking, mechanical construction and electrical construction.

Luminaires Part 1: General requirements and tests

ICS
29.140.40
CCS
K72
发布
2009-07-24
实施

Interpretation Manual No. 17-200 F3 regarding the March 2007 NF C17-200 standard.

ICS
29.260.10;93.080.40
CCS
K72
发布
2009-06-01
实施

Interpretation Manual No. 17-200 F4 on the March 2007 NF C17-200 standard.

ICS
29.260.10;93.080.40
CCS
K72
发布
2009-06-01
实施

This Standard specifies requirements for mains socket-outlet mounted nightlights for use with electric light sources, on supply voltages not exceeding 250 V a.c. 50/60 Hz. It is to be read in conjunction with those sections ofJIS C 8105-1 to which reference is made. NOTE 1 This Standard does not cover luminaires for surveillance lighting. NOTE 2 The International Standard corresponding to this Standard and the sym- bol of degree of correspondence are as follows. IEC 60598-2-12 : 2006 Luminaires--Part 2-12: Particular requirements-- Mains socket-outlet mounted nightlights (IDT) The symbols which denote the degree of correspondence in the con- tents between the relevant International Standard and JIS are IDT (identical), MOD (modified), and NEQ (not equivalent) according to ISO/ IEC Guide 21.

Luminaires -- Part 2-12: Particular requirements -- Mains socket-outlet mounted nightlights

ICS
29.140.40
CCS
K72
发布
2009-03-20
实施
2009-03-23

This Standard specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V and 50/60 Hz, for indoor or outdoor use, e.g. in gardens, yards, carriageways, parking lots, cycfeways, footways, pedestrian areas, swimming pools areas outside zones for SELV, nurseries and similar applications (hereafter referred to as "lmninaires'). This Standard is in- tended to be read in conjunction with the provisions of relevant sections JIS C 8105-1. This Standard does not cover ground recessed tuminaires for motorised roads and for airfields already specified in IEC/TS 61827. NOTE : The International Standard corresponding to this Standard and the sym- bol of degree of correspondence are as follows: IEC 60598-2-13 : 2006 Luminaires~art 2-13: Particular requirements-- Ground recessed luminaires (IDTI The symbols which denote the degree of correspondence in the con- tents between the relevant International Standard and JIS are IDT (identical), MOD (modified), and NEQ (not equivalent) according to ISO/ IEC Guide 21.

Luminaires -- Part 2-13: Particular requirements -- Ground recessed luminaires

ICS
29.140.40
CCS
K72
发布
2009-03-20
实施
2009-03-23

This translation has been made based on the Amendment to the origi- nal Japanese Industrial Standard revised by the Minister of Economy, Trade and Industry through deliberations at the Japanese Industrial Standards Committee as the result of proposal for revision of Japanese Industrial Standard with the draft being attached, based on the provi- sion of Article 12 Clause 1 of the Industrial Standardization Law ap- plicable to the case of revision by the provision of Article 14. Consequently, JIS C 7508:1996 is partially replaced with this Amend- ment.

Torch lamps (Amendment 1)

ICS
29.140.20
CCS
K72
发布
2009-02-20
实施
2009-02-20

This Part 1 of International Standard IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction and electrical construction. Each section of this Part 1 is read in conjunction with this Section 0 and with other relevant sections to which reference is made. Each part of IEC 60598-2 details requirements for a particular type of luminaire or group of luminaires on supply voltages not exceeding 1 000 V. These parts are published separately for ease of revision and additional sections will be added as and when a need for them is recognized. Attention is drawn to the fact that this Part 1 covers all aspects of safety (electrical, thermal and mechanical). The presentation of photometric data for luminaires is under consideration by the International Commission on Illumination (CIE) and is not, therefore, included in this Part 1. Requirements are included in this Part 1 for luminaires incorporating ignitors with nominal peak values of the voltage pulse not exceeding those of Table 11.2. The requirements apply to luminaires with ignitors built into ballasts and to luminaires with ignitors separate from ballasts. For luminaires with ignitors built into lamps, the requirements are under consideration. Requirements for semi-luminaires are included in this Part 1. In general, this Part 1 covers safety requirements for luminaires. The object of this Part 1 is to provide a set of requirements and tests which are considered to be generally applicable to most types of luminaires and which can be called up as required by the detail specifications of IEC 60598-2. This Part 1 is thus not regarded as a specification in itself for any type of luminaire, and its provisions apply only to particular types of luminaires to the extent determined by the appropriate part of IEC 60598-2. The parts of IEC 60598-2, in making reference to any of the sections of Part 1, specify the extent to which that section is applicable and the order in which the tests are to be performed; they also include additional requirements as necessary. The order in which the sections of Part 1 are numbered has no particular significance as the order in which their provisions apply is determined for each type of luminaire or group of luminaires by the appropriate part of IEC 60598-2. All parts of IEC 60598-2 are self-contained and therefore do not contain references to other parts of IEC 60598-2. Where the requirements of any of the sections of Part 1 are referred to in the parts of IEC 60598-2 by the phrase "The requirements of section... of IEC 60598-1 apply", this phrase is to be interpreted as meaning that all the requirements of that section of Part 1 apply except those which are clearly inapplicable to the particular type of luminaire covered by that part of IEC 60598-2. For explosion proof luminaires, as covered by IEC 60079, the requirements of IEC 60598 (selecting the appropriate parts 2) are applied in addition to the requirements of IEC 60079. In the event of any conflict between IEC 60598 and IEC 60079, the requirements of IEC 60079 take priority.

Luminaires - Part 1: General requirements and tests

ICS
29.140.40
CCS
K72
发布
2009-01-31
实施
2009-01-31

1.1 This Standard specifies performance requirements for torchieres that use non-screw-in (Edison type) lamp bases and are intended primarily for residential use. 1.2 Although this Standard largely deals with fluorescent technology, it is not intended to exclude other innovative lighting technologies, e.g., light-emitting diode (LED) or high-intensity discharge (HID) lighting, provided that they meet or exceed the performance requirements of this Standard. 1.3 In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Performance of torchieres First Edition

ICS
CCS
K72
发布
2008-07-01
实施

本标准规定了高频冷启动管形放电灯(霓虹灯)用电子换流器和变频器的性能要求。电源包括50Hz/60Hz、1000V以下的交流电源或者1000V以下的直流电源。此类换流器和变频器是一种装有触发和稳定部件的转换器,这种转换器能在直流或与电源频率不同的频率下使霓虹灯工作。与转换器匹配的霓虹灯是辉光放电灯管,本标准不包括弧光放电的低气压荧光灯用电子镇流器。

Auxiliaries for lamps.Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps(neon tubes).Peformance requirements

ICS
29.140.99
CCS
K72
发布
2008-06-16
实施
2008-12-01

Luminaires - Part 2-8: Particular requirements - Handlamps (IEC 60598-2-8:1996, modified + A1:2000 + A2:2007); German version EN 60598-2-8:1997 + A1:2000 + A2:2008

ICS
29.140.40
CCS
K72
发布
2008-06
实施
2008-06-01

1.1 This Standard applies to luminaires for use in non-hazardous locations and that are intended for installation on branch circuits of 600 V nominal or less between conductors in accordance with the Canadian Electrical Code, Part I (CEC), CSA C22.1, with the U.S. National Electrical Code (NEC), ANSI/NFPA 70, and with the Mexican National Electrical Code, NOM-001-SEDE. 1.2 This Standard does not apply to luminaires covered by other standards. The luminaries not covered by this Standard include Amateur Movie Lights; Aquarium Lights; Cabinet Lights; Decorative Lighting Strings; Combination Fan/IR Lamps Used for Heating; Electric Signs; Exit Signs in the United States; Junction Boxes for Swimming Pool Fixtures; Lamp Adapters; Low-Level Path Marking and Lighting Systems in the United States; Low-Voltage Landscape Lighting as follows: For products intended for installation in Canada, landscape lighting systems that are 30 V nominal or less; and for products intended for installation in Mexico, low-voltage landscape lighting devices that are 24 V nominal or less. For products intended for installation in the United States, low-voltage landscape lighting devices that are of 15 V nominal or less; Low Voltage Lighting Fixtures for Use in Recreational Vehicles; Low Voltage Marine Lighting; Luminaires for Hazardous Locations; Luminaires for Recreational Vehicles; Marine Navigational Lights; Marine-Type Fixtures; Portable Electric Displays; Portable Hand Lamps; Portable Luminaires; Portable Sun/Heat Lamps; Self-Ballasted Lamps and Lamp Adapters; Stage and Studio Luminaires; Submersible Luminaires; Swimming Pools Luminaires; Temporary Lighting Strings; Therapeutic Lamps; Track Lighting Systems; Under-cabinet Lights in Canada and Cord-connected Under-cabinet Lights in the United States; and Unit Equipment for Emergency Lighting.

UL Standard for Safety Luminaires Second Edition; Reprint with Revisions Through

ICS
29.140.40
CCS
K72
发布
2008-05-02
实施

This section of IEC 60598-2 specifies requirements for emergency lighting luminaires for use with electrical light sources on emergency power supplies not exceeding 1 000 V. This section does not cover the effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps. This section also includes relevant requirements and tests that shall be conducted and complied with for control gears, as specified in IEC 60924, that incorporate additional facilities such as remote control devices, indicators, changeover devices, etc.

Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting

ICS
29.140.40;91.160.10
CCS
K72
发布
2008-04
实施

This Part 1 of International Standard IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction and electrical construction. Each section of this Part 1 is read in conjunction with this Section 0 and with other relevant sections to which reference is made. Each part of IEC 60598-2 details requirements for a particular type of luminaire or group of luminaires on supply voltages not exceeding 1 000 V. These parts are published separately for ease of revision and additional sections will be added as and when a need for them is recognized. Attention is drawn to the fact that this Part 1 covers all aspects of safety (electrical, thermal and mechanical). The presentation of photometric data for luminaires is under consideration by the International Commission on Illumination (CIE) and is not, therefore, included in this Part 1. Requirements are included in this Part 1 for luminaires incorporating ignitors with nominal peak values of the voltage pulse not exceeding those of Table 11.2. The requirements apply to luminaires with ignitors built into ballasts and to luminaires with ignitors separate from ballasts. For luminaires with ignitors built into lamps, the requirements are under consideration. Requirements for semi-luminaires are included in this Part 1. In general, this Part 1 covers safety requirements for luminaires. The object of this Part 1 is to provide a set of requirements and tests which are considered to be generally applicable to most types of luminaires and which can be called up as required by the detail specifications of IEC 60598-2. This Part 1 is thus not regarded as a specification in itself for any type of luminaire, and its provisions apply only to particular types of luminaires to the extent determined by the appropriate part of IEC 60598-2. The parts of IEC 60598-2, in making reference to any of the sections of Part 1, specify the extent to which that section is applicable and the order in which the tests are to be performed; they also include additional requirements as necessary. The order in which the sections of Part 1 are numbered has no particular significance as the order in which their provisions apply is determined for each type of luminaire or group of luminaires by the appropriate part of IEC 60598-2. All parts of IEC 60598-2 are self-contained and therefore do not contain references to other parts of IEC 60598-2. Where the requirements of any of the sections of Part 1 are referred to in the parts of IEC 60598-2 by the phrase "The requirements of section... of IEC 60598-1 apply", this phrase is to be interpreted as meaning that all the requirements of that section of Part 1 apply except those which are clearly inapplicable to the particular type of luminaire covered by that part of IEC 60598-2.

Luminaires - Part 1: General requirements and tests

ICS
29.140.40
CCS
K72
发布
2008-04
实施
2014-05-28

Luminaires - Part 2-8 : particular requirements - Handlamps.

ICS
29.140.40
CCS
K72
发布
2008-03-01
实施
2008-03-20

Specifies requirements for handlamps and similar portable luminaires that are held in the hand, hooked up or resting on a surface for use with electric light sources on supply voltages not exceeding 250 V.

Luminaires Part 2-8: Particular requirements - Handlamps

ICS
29.140.40
CCS
K72
发布
2008-02-29
实施

本标准规定了使用电光源、电源电压不超过250V50-60Hz的电源插座安装的夜灯的要求。本标准应与GB 7000.1一直使用。

Mains socket-outlet mounted nightlights

ICS
29.140
CCS
K72
发布
2007-12-03
实施
2008-06-01

本标准规定了电源电压不超过1000V的电光源的地面嵌入式灯具的专门要求,该类灯具适于在室内或室外使用,如庭园、院子、车道、停车场、自行车道、人行道、行人徙步区域、游泳池外围的安全特低电压区域、托儿所和类似场所。 本标准不适用安装在机动车道和由IEC 61827规定的机场跑道上的地面嵌入式灯具。

Ground recessed luminaires

ICS
29.140
CCS
K72
发布
2007-12-03
实施
2008-06-01

本标准规定了使用电光源、工作电源电压不超过1000V灯具的型号命名方法,适用于我国生产的此范围内的相关灯具。

Rules of luminaire type

ICS
29.140
CCS
K72
发布
2007-12-03
实施
2008-06-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号