K72 一般灯具 标准查询与下载



共找到 737 条与 一般灯具 相关的标准,共 50

Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 3 : presentation of data for emergency lighting of work places.

ICS
17.180.20;91.160.10
CCS
K72
发布
2007-12-01
实施
2007-12-14

This standard specifies the required data for lamps and luminaires to verify conformity with EN 1838. This standard does not define the data requirements for signage, as these can be found in EN 1838.

Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 3: Presentation of data for emergency lighting of work places; English version of DIN EN 13032-3:2007-12

ICS
17.180.20;91.160.10
CCS
K72
发布
2007-12
实施

This standard specifies the required data for lamps and luminaires to verify conformity with EN 1838. This standard does not define the data requirements for signage, as these can be found in EN 1838.

Measurement and presentation of photometric data of lamps and luminaires - Presentation of data for emergency lighting of work places

ICS
17.180.20;91.160.10
CCS
K72
发布
2007-11-30
实施
2007-11-30

This standard specifies the luminous requirements for emergency lighting systems installed in premises or locations where such systems are required. It is principally applicable to locations where the public or workers have access.

Emergency lighting

ICS
91.160.10
CCS
K72
发布
2007-11
实施

Luminaires - Part 1: General requirements and tests (IEC 60598-1:2003, modified); German version EN 60598-1:2004, Corrigenda to DIN EN 60598-1 (VDE 0711-1):2005-03; German version CENELEC-Cor,: 2007 to EN 60598-1:2004

ICS
29.140.40
CCS
K72
发布
2007-11
实施

この規格は.全作業時間にわたって視作業を.効率よく,かつ,快適で,安全に行うための屋内作業場の照明設計基準.照明要件などについて規定する。 なお,この規格は,特定の作業場の最適化のために照明システム及び技術をどのように設計することが望ましいかを記載するものではない。また.特定の作業場の最適化のために照明システム及び技術をどのように設計することが望ましいかについては,関連の国際照明委員会(以下,CIEという。)ガイド及び報告書に記載されている。

Lighting of indoor work places

ICS
13.180;91.160.10
CCS
K72
发布
2007-10-20
实施

Applies to tungsten filament incandescent lamps for general lighting service which comply with the safety requirements in IEC 60432-1 (published in South Africa as an identical adoption under the designation SANS 60432-1).

Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements

ICS
29.140.20
CCS
K72
发布
2007-10-12
实施

ERRATUM

ICS
CCS
K72
发布
2007-09-12
实施

Specifies requirements for luminaires for fluorescent lamps which are equipped with electronic ballasts for use on d.c. supplies of rated voltage not exceeding 250 V. The d.c. supply could be a solar energy system.

D.C. supplied luminaires for fluorescent lamps

ICS
29.140.30
CCS
K72
发布
2007-09-07
实施

Decentralized Rural Electrification Systems (DRES) are designed to supply electric power to sites which are not connected to a large interconnected system, or a national grid. As described in the IEC 62257-1, these systems include: • an electrical power production subsystem; • a secondary grid for sharing/distributing this power, when the system is a collective electrification system (microgrid); • a subsystem for utilizing this electrical power as a demand subsystem including the in-house wiring and user's electrical appliances. In many situations, lighting is the most expected application of the rural electrification process and the first application that the users may afford. For a given lighting performance, the electrical characteristics of the lamps may vary, particularly the power factor and the harmonic content. On large grids, the impact of these characteristics is generally not a major issue. In the context of the electrification systems considered in the IEC 62257 series, the main applications are lighting and TV. In these small systems, the power factor and the harmonic content of the supplied appliances have a high impact on the design and the sizing of the production and distribution subsystems as well as on the quality of the service provided. Project implementers cannot afford an over-sizing of any part of the system. For this reason, they have to make sure that the selected appliances have characteristics which do not adversely affect the cost of the equipment necessary to provide the quality of service required by the General Specification of the project. Some relevant products are available on the market (high power factor and low harmonic content).The purpose of this technical specification is to help project implementers to discriminate, in a potential sourcing panel, the models of lamps which could have the lowest impact on the whole system (generation and distribution subsystems). This specification deals with integral compact fluorescent technology lamps: • power less than 60 W; • with an Edison screw E27 or bayonet B22 cap; • with nominal voltage from 100 V to 250 V a.c. IEC 60969 specifies the performance requirements together with the test methods and conditions required to show compliance of tubular fluorescent and other gas-discharge lamps with integrated means for controlling starting and stable operation (self-ballasted lamps) intended for domestic and similar general lighting purpose. This specification must be considered as the reference for the manufacturers. This technical specification proposes comparative tests that could be particularly useful for project implementers to test in laboratories of developing countries the capability of products to be used for their project. The tests can be performed locally, as close as possible of the real site operating conditions. This technical specification does not cover other lamp technologies (e.g. d.c. lamps, leds, etc ) however similar principles can be used for such comparative testing. Additionally some recommendations are suggested in Annex A in order to enhance the performances or effectiveness of the lighting sources using a luminaire. This specification is not a type approval standard. It is a technical specification to be used as guidelines and does not replace any existing IEC standard on lamps.

Recommendations for small renewable energy and hybrid systems for rural electrification - Selection of self-ballasted lamps (CFL) for rural electrification systems and recommendations for household lighting equipment

ICS
27.190;29.140.30;29.140.99
CCS
K72
发布
2007-08-31
实施
2007-08-31

This Part 2-8 of IEC 60598 specifies requirements for handlamps and similar portable luminaires which are held in the hand, hooked up or resting on a surface for use with electric light sources on supply voltages not exceeding 250 V. It is to be read in conjunction with those sections of Part 1 to which reference is made. Handlamps which can be fixed to a support by means of a wing screw, clip or magnet, and luminaires intended for inspection of the interior of barrels, are within the scope of this section.

Luminaires - Part 2-8: Particular requirements - Handlamps

ICS
29.140.40
CCS
K72
发布
2007-07
实施

Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 2: Presentation of data for indoor and outdoor work places; German version EN 13032-2:2004, Corrigenda to DIN EN 13032-2:2005-03; German version EN 13032-

ICS
17.180.20;29.140.01
CCS
K72
发布
2007-07
实施

This Technical Specification applies to portable solar photovoltaic lanterns (portable PV lantern). This specification is independent of the technology used to provide the light. The tests provided in this specification are able to help the project implementer to discriminate easily the most appropriate product within some different market offer and choose among them those which match the requirements expressed in the GS of the electrification project (see IEC/TS 62257-3). The specification also provides provisions of regulations and installation conditions to be complied with in order to ensure the life and proper operation of the selected lantern as well as the safety of people living in proximity to the installation. This technical specification does not replace any existing IEC standard. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 62262, Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 illuminance (of an elementary surface) (symbol E) the luminous flux received by an elementary surface divided by the area of this surface. [IEV 723-08-30] NOTE In the Sl system of units illuminance is expressed in lux (Ix) or lumens per square metre (Im/m2). 1 lux is the illuminance produced on a surface of 1 square metre by a luminous flux of 1 lumen uniformly distributed over that surface.

Recommendations for small renewable energy and hybrid systems for rural electrification - Part 9-5: Integrated system - Selection of portable PV lanterns for rural electrification projects

ICS
27.160;27.180;27.190;29.140.40
CCS
K72
发布
2007-06
实施

This is Amendment 2 to IEC 60598-2-8-2007 (Luminaires Part 2-8: Particular requirements-Handlamps)

Luminaires - Part 2-8: Particular requirements - Handlamps; Amendment 2

ICS
29.140.40
CCS
K72
发布
2007-06
实施
2007-07-27

Luminaires - Part 1: General requirements and tests (IEC 60598-1:2003/A1:2006); German version EN 60598-1:2004/A1:2006

ICS
29.140.40
CCS
K72
发布
2007-06
实施
2007-06-01

Specifies requirements for ground recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V, for indoor or outdoor use, for example, in gardens, yards, carriageways, parking lots, cycleways, footways, pedes

Luminaires Part 2-13: Particular requirements - Ground recessed luminaires

ICS
29.140.40
CCS
K72
发布
2007-04-20
实施

Luminaires - Part 2-13: Particular requirements - Ground recessed luminaires (IEC 60598-2-13:2006); German version EN 60598-2-13:2006, Corrigenda to DIN EN 60598-2-13 (VDE 0711-2-13):2007-02; CENELEC-Corrigendum December 2006 to EN 60598-2-13:2006

ICS
29.140.40
CCS
K72
发布
2007-04
实施

External lighting installations - Requirements.

ICS
29.260.10;93.080.40
CCS
K72
发布
2007-03-01
实施
2007-03-20

This Standard specifies requirements for working lights which are used by the fire brigade.

Working light for low voltage

ICS
91.160.10
CCS
K72
发布
2007-03
实施

This International Standard specifies the basic performance and safety requirements for individual products and components that are incorporated into automatic test systems for use with emergency lighting systems on supply voltages not exceeding 1000 V. This standard also specifies the required functionality of a complete automatic test system for an emergency lighting system. This standard is applicable to testing systems consisting of a number of emergency lighting self-contained luminaires or a central battery with associated emergency lighting luminaires.

Automatic test systems for battery powered emergency escape lighting

ICS
29.140.50
CCS
K72
发布
2007-02-28
实施
2007-02-28



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号