K73 特殊灯具 标准查询与下载



共找到 556 条与 特殊灯具 相关的标准,共 38

This standard is intended to be used for the presentation of photometric data for luminaires used in the entertainment and performance industries. This standard defines the minimum photometric data to be presented on documents purporting to accurately describe the photometric performance of these luminaires. It does not prohibit the presentation of information inaddition that required by this standard.

Reporting Photometric Performance Data for Luminaires Used in Entertainment Lighting

ICS
17.220.20;97.200.10
CCS
K73
发布
2007-03-07
实施

MS53023B is inactive for new design and is no longer used, except for replacement purposes.

HEADLIGHT-SERVICE, DOUBLE FILAMENT, 24 VOLT, WATERPROOF

ICS
29.140.40
CCS
K73
发布
2007-01-26
实施

This proposal includes substantive changes to requirements originally balloted to the STP on July 1, 2005.

UL Standard for Safety Portable Electric Luminaries COMMENTS DUE: January 14, 2008 [Superseded: UL 298, UL 298, UL 298]

ICS
29.140.40
CCS
K73
发布
2007
实施

本部分规定了游泳池及类似场所用灯具的要求、检验及判定。 本部分适用于在水中使用或与水接触的固定式灯具,如游泳池水槽、喷水池、划水池和花园水池中使用钨丝灯泡的灯具。 本部分不适用于不与水接触的灯具(例如:安装在与灯具分开的下班板后面)或手提式灯具。

Rules for the inspection of luminaires for import and export. Part 3: Particular requirements of luminaires for swimming pools and similar applications

ICS
29.140
CCS
K73
发布
2006-11-10
实施
2007-05-10

This part of IEC 62013 specifies requirements for the construction and testing of caplights, including caplights with a point of connection for another apparatus, for use in mines susceptible to firedamp (Group I – electrical apparatus for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition. The requirements of IEC 60079-0 do not apply unless specified. This standard is also applicable to caplights intended for use in mines which have become temporarily endangered by an explosive gas atmosphere, for example in mine rescue operations. Caplights complying with this standard are intended for personal use under normal conditions of: Temperature: 0 ℃ to +40 ℃ Pressure: 0,8 bar to 1,1 bar

Caplights for use in mines susceptible to firedamp. General requirements. Construction and testing in relation to the risk of explosion

ICS
29.260.20;73.100.20
CCS
K73
发布
2006-09-29
实施
2006-09-29

MIL-L-26202 LIGHT, MARKER, AIRPORT, SEMIFLUSH,GENERAL SPECIFICATION FOR

LIGHT, MARKER, AIRPORT, SEMIFLUSH, GENERAL SPECIFICATION FOR

ICS
29.140.40
CCS
K73
发布
2006-08-17
实施

This specification establishes the Emergency Egress Lighting Subassembly (EELS) requirements for fixed wing, rotary wing, lighter-than-air, and tilt-rotor aircraft and fixed wing or rotary wing aircraft configured as passenger carrying aircraft.

LIGHTING, EMERGENCY EGRESS, SUBASSEMBLY

ICS
29.140.40
CCS
K73
发布
2006-08-10
实施

This international standard specifies performance requirements for electronic control gear for use on d.c. supplies up to 250 V and a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with an output frequency which can deviate from the supply frequency, associated with LED modules according to IEC 62031. Control gear for LED modules specified in this standard are designed to provide constant voltage or current. Deviations from the pure voltage and current types do not exclude the gear from this standard. NOTE 1 The tests in this standard are type tests. Requirements for testing individual control gear during production are not included. NOTE 2 Requirements for control gear which incorporate means for varying the output power are under consideration. NOTE 3 It may be expected that control gear complying with this standard will ensure satisfactory operation between 92 % and 106 % of the rated supply voltage, taking into account the specifications of the LED module manufacturer.

D.C. or A.C. supplied electronic control gear for LED modules - Performance requirements

ICS
29.140.99;31.080.99
CCS
K73
发布
2006-08
实施
2011-04-01

To be read in conjunction with BS EN 60598-1

Luminaires - Part 2-11: Particular requirements - Aquarium luminaires

ICS
29.140.40
CCS
K73
发布
2006-07-31
实施
2006-07-31

MS52126A, dated 19 September 2001, has been reviewed and determined to be valid for use in acquisition.

COMPOSITE LIGHT FRONT, TURN, PARK AND MARKER

ICS
29.140.40
CCS
K73
发布
2006-07-24
实施

The document describes the basic testing conditions for measuring the photometric output of a stage or studio luminaire by testing method that measure the illumination levels produced by the luminaire on a planar surface. These testing methods include, but are not limited to, measurements taken by digital cameras or hand-held meters. This atandard is not intended to give guidance on testing conditions for methods that use goniophotometers.

Recommended Basic Conditions for Measuring the Photometric Output of Stage and Studio Luminaires by Measuring Illumination Levels Produced on a Planar Surface

ICS
97.200.10
CCS
K73
发布
2006-07-13
实施

This list has been prepared for use by or for the Government in the acquisition of products covered by the subject specification and such listing of a product is not intended to and does not connote endorsement of the product by the Department of Defense. All roducts listed herein have been qualified under the requirements for the product as specified in the latest effective issue of the applicable specification. This list is subject to change without notice; revision or amendment of this list will be issued as necessary. The listing of a product does not release the supplier from compliance with the specification requirements.

LIGHTS, COCKPIT UTILITY, AIRCRAFT, GENERAL SPECIFICATION FOR

ICS
29.140.40
CCS
K73
发布
2006-07-12
实施

This is Amendment 1 to IEC 60598-1-2003 (Luminaires Part 1: General requirements and tests)

Luminaires - Part 1: General requirements and tests - Thermal test for thermoplastic luminaires - Amendment 1

ICS
29.140.40
CCS
K73
发布
2006-07
实施

This International Standard specifies the basic performance and safety requirements for individual products and components that are incorporated into automatic test systems for use with emergency lighting systems on supply voltages not exceeding 1000 V. This standard also specifies the required functionality of a complete automatic test system for an emergency lighting system. This standard is applicable to testing systems consisting of a number of emergency lighting self-contained luminaires or a central battery with associated emergency lighting luminaires. NOTE Manual test facilities that rely on manual initiation and/or visual inspection of the lamp condition are outside the scope of this standard.

Automatic test system for battery powered emergency escape lighting

ICS
91.160.10
CCS
K73
发布
2006-05
实施
2012-02-23

This configuration standard covers the dimensional requirements and mechanical requirements related to intermateability for a series of split-pin and sleeve wiring devices known as Pin Connectors or Stage Pin Connectors that are used predominately in the theatre, television and motion picture industries in North America. This is not a safety standard.

Entertainment Technology - Dimensional Requirements for Stage Pin Connectors

ICS
97.200.10
CCS
K73
发布
2006-04-06
实施

Covers performance requirements for luminaires for interior lighting, streetlighting and floodlighting for operation with fluorescent lamps, low-pressure sodium vapour lamps or high-intensity discharge lamps, for use on a.c. supply voltages with a freque

Luminaires for interior lighting, streetlighting and floodlighting - Performance requirements

ICS
29.140.40
CCS
K73
发布
2006-03-24
实施
2006-03-24

1.1 These requirements cover shatter containment mechanisms for lamps for use in food applications where prevention of contamination from broken glass is preferable. 1.2 These requirements do not apply to the lighting fixtures (luminaires), lamp holders or other apparatus that support the lamps and/or shatter containment mechanism. 1.3 Some types of lamps, including fluorescent and high intensity discharge (HID) lamps, require small amounts of mercury to efficiently function. These requirements do not cover the containment or potential release of mercury upon lamp breakage.

OUTLINE OF INVESTIGATION FOR SHATTER CONTAINMENT OF LAMPS FOR USE IN REGULATED FOOD ESTABLISHMENTS Issue 1

ICS
CCS
K73
发布
2006-03-03
实施

1.1 This Standard applies to emergency lighting and power equipment for use in unclassified locations and intended for connection to branch circuits of 600 volts or less. Such equipment is intended to automatically supply illumination or power or both to critical areas and equipment in the event of failure of the normal supply, in accordance with Article 700 or 701 of the National Electrical Code, NFPA 70, the Life Safety Code, NFPA 101, and the International Building Code, IBC. 1.2 Examples of equipment described in 1.1 include: Exit Signs Emergency Luminaires Unit Equipment Central Station Battery Banks Inverters Automatic Battery Charging and Control Equipment Automatic Load Control Relays Derangement Signal Equipment. 1.3 This Standard also applies to auxiliary lighting and power equipment for use in unclassified locations. Auxiliary equipment has not been investigated to determine compliance with the performance requirements of Article 700 or 701 of the National Electrical Code, NFPA 70, the Life Safety Code, NFPA 101, or the International Building Code. Such equipment includes luminaires with an integral battery backup power supply, illuminated directional signs, battery assemblies, and related devices. 1.4 This Standard does not include requirements for equipment covered by other Standards, such as: Luminaires, UL 1598; Uninterruptible Power Supply Equipment, UL 1778; Low Level Path Marking and Lighting Systems, UL 1994; Transfer Switch Equipment, UL 1008; Electric Signs, UL 48.

Emergency Lighting and Power Equipment

ICS
91.140.50;91.160.10
CCS
K73
发布
2006-02-24
实施

This standard is intended to cover physical, operational, maintenance, and light-distribution features that permit use of high-mast luminaires in roadway applications when specified.

Roadway and Area Lighting Equipment - High-mast Side-mounted Luminaires for Horizontal- or Vertical-burning High-intensity Discharge Lamps

ICS
29.140.40;29.140.30;93.080.40
CCS
K73
发布
2006-01-11
实施

These requirements cover: Luminaires for installation & use in hazardous (classified) locations, Cl I, Div 1 & 2, Gps A, B, C, & D; Cl II, Div 1, Gps E, F, & G; Cl II, Div 2, Gps F & G; & Cl III, Div 1 & 2, in accordance with the NEC, ANSI/NFPA 70. Explosion-proof luminaires for installation & use in Cl I, Zone 1, Gps IIA, IIB, IIB plus Hydrogen & IIC hazardous (classified) locations. Luminaires for use only under the following atmospheric conditions: a) A min. ambient temperature of -25?C (-13?F), b) An oxygen concentration not greater than 21% by volume, and c) A nominal barometric pressure of one atmosphe.

Standard for Safety for Electric Lighting Fixtures for Use in Hazardous (Classified) Locations

ICS
29.140.40
CCS
K73
发布
2006-01-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved