共找到 61 条与 相关的标准,共 5 页
本标准规定了电子电气产品塑料部件中多环芳烃的高效液相色谱测定方法。 本部分适用于电子电气产品塑料部件中多环芳烃的测定。
Determination of polycyclic aromatic hydrocarbons in electrical and electronic equipment.Part 1:High performance liquid chromatography
本标准规定了电子电气产品塑料部件中有机锡的傅立叶变换红外光谱(FT-IR)定性筛选方法。 本部分适用于电子电气产品塑料部件中有机锡的红外定性筛选。
Determination of organotin compounds in electrical and electronic equipment.Part 2:Screening by Fourier transform infrared spectrometry
本标准规定了电子电气产品塑料部件中11种邻苯二甲酸酯类物质的高效液相色谱测定方法。 本部分适用于电子电气产品塑料部件中11种邻苯二甲酸酯类物质的测定。
Determination of phthalates in electrical and electronic equipment.Part 3:High performance liquid chromatography
本标准规定了电子电气产品塑料部件中15种邻苯二甲酸酯类物质的气相色谱-质谱测定方法。 本部分适用于电子电气产品塑料部件中15种邻苯二甲酸酯类物质的测定。
Determination of phthalates in electrical and electronic equipment.Part 2:Gas chromatography-mass spectrum
本标准规定了电子电气产品塑料部件中12种邻苯二甲酸酯类物质的气相色谱测定方法。 本部分适用于电子电气产品塑料部件中12种邻苯二甲酸酯类物质的测定。
Determination of phthalates in electrical and electronic equipment.Part 1:Gas chromatography
This International Standard specifies general procedures to integrate environmental aspects into design and development processes of electrical and electronic products.
Environmentally conscious design for electrical and electronic products (IEC 62430:2009); German version EN 62430:2009
This International Standard specifies requirements and procedures to integrate environmental aspects into design and development processes of electrical and electronic products, including combination of products, and the materials and components of which they are composed (hereafter referred to as products).
Environmentally conscious design for electrical and electronic products
Covers safety requirements for electrical and electronic apparatus.
Electrical and electronic apparatus
This part of IEC 60068 specifies whisker tests for electric or electronic components representing the finished stage, with tin or tin-alloy finish. However, the standard does not specify tests for whiskers that may grow as a result of external mechanical stress. This test method is employed by a relevant specification (international component or application specification) with transfer of the test severities to be applied and with defined acceptance criteria. Where tests described in this standard are considered for other components, e.g. mechanical parts as used in electrical or electronic equipment, it should be ensured that the material system and whisker growth mechanisms are comparable.
Environmental testing - Part 2-82: Tests - Test XW1: Whisker test methods for electronic and electric components
To ensure compliance with the marking requirements of the WEEE Marking Requirements, this standard is applicable to all manufacturers and producers of electrical and electronic equipment distributed within the EU. This standard will also be of interest
Marking of electrical and electronic equipment in accordance with article 11(2) of Directive 2002/96/EC (WEEE)
This European Standard specifies a marking · of electrical and electronic equipment in accordance with Article 11(2) of Directive 2002/96/EC (WEEE); NOTE This is in addition to the marking requirement in Article 10(3) of this Directive which requires producers to mark electrical and electronic equipment put on the market after 13 August 2005 with a 'crossed-out wheeled bin' symbol. · that applies to electrical and electronic equipment falling under Annex IA of Directive 2002/96/EC, provided the equipment concerned is not part of another type of equipment that does not fall within the scope of this Directive. Annex IB of Directive 2002/96/EC contains an indicative list of the products, which fall under the categories set out in Annex IA of this Directive; · that serves to clearly identify the producer of the equipment and that the equipment has been put on the market after 13 August 2005. The definition of a technical carrier medium for identifying the producer, such as a barcode, electronic data medium or microchip, is not covered by this standard.
Marking of electrical and electronic equipment in accordance with article 11(2) of directive 2002/96/EC (WEEE)
This part of IEC 61010 specifies general safety requirements for electrical equipment intended for professional, industrial process, and educational use, any of which may incorporate computing devices, as defined in a) to d) below, when used under the environmental conditions of 1.4 a)Electrical test and measurement equipment b)Electrical control equipment c)Electrical laboratory equipment d)Accessories intended for use with the above (for example, sample handling equipment).
Electric and Electronic Test, Measuring, Controlling, and Related Equipment: General Requirements
Specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of specimens made from plastics and other non-metallic materials, as well as their resistance to burn-through when exposed to a flame ignition source of 5
Fire hazard testing - Part 11-20: Test flames; 500 W flame test methods
Specifies a small-scale laboratory screening procedure for comparing the relative burning behaviour of vertically or horizontally oriented specimens made from plastic and other non-metallic materials, exposed to a small-flame ignition source of 50 W nomi
Fire hazard testing - Part 11-10: Test flames; 50 W horizontal and vertical flame test methods
GB/T 5169的本部分规定了使用丙烷燃气产生l kW标称预混合型试验火焰的具体要求。 本部分适用于电工设备及其组件和零部件,还适用于同体电气绝缘材料或其他固体可燃材料。
Fire hazard testing - Part 11-2: Test flames; 1 kW nominal pre-mixed flame; Apparatus, confirmatory test arrangement and guidance
This part of IEC 60352 is applicable to solderless press-in connections for use in tele-communication equipment and in electronic devices employing similar techniques. The press-in connection consists of a termination having a suitable press-in zone which is inserted into a plated-through hole of a double-sided or multilayer printed board. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this part of IEC 60352 is to determine the suitability of press-in connections under specified mechanical, electrical and atmospheric conditions. Only compliant press-in zones can be qualified according to this specification. Solid press-in zones are in use. Information about these is given in annex A.
Solderless connections - Part 5: Press-in connections; General requirements, test methods and practical guidance
Letter symbols to be used in electrical technology - Part 2 : Telecommunications and electronics
This standard is Fire hazard testing - Part 11-20: Test flames - 500 W flame test methods; Corrigendum 1.
Fire hazard testing - Part 11-20: Test flames - 500 W flame test methods; Corrigendum 1
The seventh edition of IEEE 100 has been revised to include nearly 35 000 technical terms and definitions from over 800 standards—covering areas such as power and energy, communications, information technology, and transportation systems. In addition to an extensive list of widely used acronyms and abbreviations, this new edition also contains detailed abstracts of each term’s associated standard(s). What’s more, all definitions are augmented by a combination of indispensable information, including: ? Preferred and popular usage of each term ? Variations in meanings among different technicalspecial ties ? Cross-indexing to related works ? Key explanatory notes for further term clarification
Dictionary of electrical and electronics terms
This technical specification is applicable to flat, solid non-metallic specimens of materials used in electrotechnical products. This method is not applicable to the testing of non-flat products such as insulated wires and cables, as it is not possible to obtain a satisfactory distribution of heat flux with such products. This method may not be applicable for materials which melt and flow away from the direct impingement of heat flux and do not give a smoke emission, which is representative of current knowledge from real fire situations. The purpose of this technical specification is to determine, under certain specific experimental conditions, the optical density of smoke produced by materials exposed vertically to a radiant heat source with or without the application of a pilot flame in a closed chamber (i.e. without air-change).
Fire hazard testing - Part 6-31: Smoke obscuration - Small-scale static test - Materials