L17 电感器、变压器 标准查询与下载



共找到 443 条与 电感器、变压器 相关的标准,共 30

This International Standard applies to inductors designed for electromagnetic interference suppression intended for use within, or associated with, electronic or electrical equipment and machines. It is restricted to inductors for which safety tests are appropriate. The combination of two or more inductors within one enclosure is also included. Inductors within the scope of this standard may also be used to protect apparatus and machines from electrical noise and voltage or current transients coming from either the supply or from other parts of the apparatus. This standard does not necessarily apply in its entirety to inductors intended for use on motor vehicles, in aircraft or for marine applications.

Fixed inductors for electromagnetic interference suppression — Part 1: Generic specification

ICS
29.180;33.100.01
CCS
L17
发布
2000-04-15
实施
2000-04-15

この規格は,定格供給電圧が交流1000V以下及び500Hz以下の定格周波数をもつ,提携されるかそれとは別の据置形又は可搬形,単相又は多相,空冷形の絶縁変圧器及び安全絶縁変圧器で,次の値の定格出力を超えないものに適用する。

Isolating transformers and safety isolating transformers -- Requirements

ICS
29.180
CCS
L17
发布
2000-03-20
实施

Pertains to electronic wide-band transformers transmitting power within a wide band of frequencies covering typically at least one decade in the frequency spectrum. Provision is made for including data for use in the design of feedback amplifiers and control networks or other circuits in which the knowledge of the transformer amplitude and phase-frequency response is needed by the system designer. These transformers are required to transform voltage within specified tolerances of amplitude and phase when operating between specified impedances. Guides to the application and test procedures are included. These appendixes contain certain precautions and recommended practices. The standard also pertains to hybrid transformers, primarily used in the telecommunications industry. The hybrid transformer is a wide-band transformer used in a manner which makes it part of a capacitance, resistance and/or inductance network and it must have characteristics which permit it to match the network for proper overall performance.

Standard for Wide Band (Greater than 1 Decade) Transformers

ICS
29.180
CCS
L17
发布
2000
实施

This part of IEC 44 applies to newly manufactured current transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. Although the requirements relate basically to transformers with separate windings, they are also applicable, where appropriate, to autotransformers. Clause 11 covers the requirements and tests, in addition to those in clauses 3, 4, 5, 6, 7, 8, 9 and 10, that are necessary for current transformers for use with electrical measuring instruments. Clause 12 covers the requirements and tests, in addition to those in clauses 3, 4, 5, 6, 7, 8, 9 and 10, that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection in which the prime requirement is the maintenance of accuracy up to several times the rated current. For certain protective systems, where the current transformer characteristics are dependant on the overall design of the protective equipment (for example, high-speed balanced systems and earth-fault protection in resonant earthed networks), additional requirements are given in clause 13 for class PR transformers and in clause 14 for class PX transformers. Clause 13 covers the requirements and tests in addition to those in clause 3, 4, 5, 6, 7, 8, 9 and 10 that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection in which the prime requirement is the absence of remanent flux. Clause 14 covers the requirements and tests in addition to those in clauses 3, 4, 5, 6, 7, 8, 9 and 10 that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection for which knowledge of the transformer's secondary excitation characteristic, secondary winding resistance, secondary burden resistance and turns ratio is sufficient to assess its performance in relation to the protective relay system with which it is to be used. Current transformers intended for both measurement and protection shall comply with all the clauses of this standard. Instrument transformers (ITs) are considered to be passive elements. NOTE For outdoor ITs having voltages ≥ 123 kV the RIV measurements are suitable to cover the requirements of EMC Directive. For guidance of the test procedure EN 60694:1996, §6.3 might be followed.

Instrument transformers - Current transformers

ICS
17.220.20
CCS
L17
发布
1999-11-15
实施
1999-11-15

Type TI of miniature closed transformers Detail specification of

ICS
29.180
CCS
L17
发布
1999-11-10
实施
1999-12-01

本规范规定了28 Vd.c.铁芯电感器的分类、要求、质量保证规定和交货准备。 本规范适用于军用开关、继电器和断路器实验室用感应电流额定值低于100 A的铁芯电感器。

Inductor,28 Vd.c.laboratory test general specification for

ICS
29.180
CCS
L17
发布
1999-11-10
实施
1999-12-01

This International Standard applies to fixed inductors designed for electromagnetic interference suppression and which fall within the scope of the generic specification, IEC 60938-1. It is restricted to fixed inductors for which safety tests are appropriate. This implies that inductors specified according to this specification will either be connected to mains supplies, when compliance with the mandatory tests of table 1 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. This standard applies to fixed inductors which will be connected to an a.c. mains or other supply with a nominal voltage not exceeding 1 000 V a.c. (r.m.s.) or d.c. between conductors and with a nominal frequency not exceeding 400 Hz.

Fixed inductors for electromagnetic interference suppression - Part 2: Sectional specification

ICS
29.180
CCS
L17
发布
1999-11
实施
2006-12-05

Fixed inductors for electromagnetic interference suppression -Part 2-2:Blank detail specification - Inductors for which safety tests are required (only) General data Inspection requirements

Fixed inductors for electromagnetic interference suppression - Part 2-2: Blank detail specification - Inductors for which safety tests are required (only)

ICS
29.180
CCS
L17
发布
1999-10
实施
1999-11-11

Fixed inductors for electromagnetic interference suppression -Part 2-1:Blank detail specification -Inductors for which safety tests are required -Assessment level D General data Inspection requirements

Fixed inductors for electromagnetic interference suppression - Part 2-1: Blank detail specification - Inductors for which safety tests are required - Assessment level D

ICS
29.180
CCS
L17
发布
1999-10
实施
1999-11-11

This International Standard applies to inductors designed for electromagnetic interference suppression intended for use within, or associated with, electronic or electrical equipment and machines. It is restricted to inductors for which safety tests are appropriate. The combination of two or more inductors within one enclosure is also included. inductors within the scope of this standard may also be used to protect apparatus and machines from electrical noise and voltage or current transients coming from either the supply or from other parts of the apparatus. This standard does not necessarily apply in its entirety to inductors intended for use on motor vehicles, in aircraft or for marine applications.

Fixed inductors for electromagnetic interference suppression - Part 1: Generic specification

ICS
29.180
CCS
L17
发布
1999-10
实施
2006-09-29

This part of IEC 44 applies to new inductive voltage transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. Although this standard relates basically to transformers with separate windings, it is also applicable, where appropriate, to auto-transformers. This standard does not apply to transformers for use in laboratories. NOTE Requirements specific to three-phase voltage transformers are not included in this standard but, so far as they are relevant, the requirements in clauses 3 to 11 apply to these transformers and a few references to them are included in those clauses (e.g. see 2.1.4, 5.1.1, 5.2, and 11.2). Clause 13 covers the requirements and tests, in addition to those in clauses 3 to 12, that are necessary for single-phase inductive protective voltage transformers. The requirements of clause 13 apply particularly to transformers which are required to have sufficient accuracy to operate protective systems at voltages that occur under fault conditions. Instrument transformers (ITs) are considered to be passive elements. NOTE For outdoor ITs having voltages ≥ 123 kV the RIV measurements are suitable to cover the requirements of the EMC Directive. For a guidance of the test procedure EN 60694:1996, §6.3 might be followed. Three-phase inductive voltages transformers are covered by HD 587 S1.

Instrument transformers - Inductive voltage transformers

ICS
17.220.20
CCS
L17
发布
1999-08-15
实施
1999-08-15

  本标准规定了控制用电流互感器的产品分类、技术要求、试验方法、检验规则、产品标志和铭牌的基本内容,包装、运输及贮存的基本要求,产品随带的文件。   本标准适用于电压等级为1.2kV及以下,额定频率为50Hz或60Hz,电压等级为1.25kV直流的控制用电流互感器。   控制用电流互感器供电控制和变流设备用于电气测量、电流反馈和电气保护。包括:   电流互感器   直流电流互感器   双向直流电流互感器   交直流电流互感器

Control current transformers

ICS
29.180
CCS
L17
发布
1999-08-06
实施
2000-01-01

This specification covers the general requirements for power transformers, power inductors, audio transformers, audio inductors, high power pulse transformers, charging inductors, saturable transformers and saturable inductors for use in electronic and communication equipment. This specification covers transformers and inductors weighing 300 pounds or less or having root-mean-square (rms) test-voltage ratings 0f 50,000 volts or less, and also high-power pulse transformers where the peak pulse power is greater than 5 watts. Transformer and inductor assemblies incorporating any other active or passive components do not come within the scope of this specification.

TRANSFORMERS AND INDUCTORS (AUDIO, POWER, AND HIGH-POWER PULSE), GENERAL SPECIFICATION FOR

ICS
29.180
CCS
L17
发布
1999-06-25
实施

MIL-S-55689(EL) is inactive for new design and is no longer used, except for replacement purposes.

SUPPRESSOR, ELECTRICAL TRANSIENT, MX-7778( )/GRC

ICS
29.180
CCS
L17
发布
1999-03-31
实施

MIL-T-83720 is inactive for new design and is no longer used, except for replacement purposes.

TRANSFORMERS AND INDUCTORS, NON-EXPLOSIVE, GENERAL SPECIFICATION FOR

ICS
29.180
CCS
L17
发布
1999-03-31
实施

The document applies to inductive voltage dividers which are designed to provide a number of accurate ratios of alternating voltage over a range frequencies and are intended to be used with negligible burden on their output.

Inductive voltage dividers (IEC 60618:1978 + A1:1981 + A2:1997); German version EN 60618:1997 + A2:1997

ICS
29.200
CCS
L17
发布
1999-03
实施

General recommendations for the loading of dry-type distribution and power transformers that have 80 C, 115 C, and 150 C average winding rises and insulation systems limited to 150 C, 180 C, and 220 C maximum hottest-spot operating temperatures, respectively, are covered in this guide.

Distribution and Power Transformers, Guide for Loading Dry-Type (appendix to ANSI C57.12 standards)

ICS
29.180
CCS
L17
发布
1999
实施

Applies to capacitors for coupling power-line carrier and for reducing rate of rise of breaker transient recovery voltage, and to coupling capacitor voltage transformers (CCVT) for connection to a high-voltage power circuit, between line and ground, to supply a low voltage for measurement, control, and protective functions. A CCVT may or may not have provision for power-line carrier coupling. This is the second public review for this standard. It first appeared in the February 27, 1997 issue of Standards Action and is being resubmitted now due to substantive changes to the text.

Power Line Carrier Coupling Capacitors and Coupling Capacitor Voltage Transformers (CCVT) - Requirements

ICS
31.060.99
CCS
L17
发布
1999
实施

이 규격은 주위 온도가 최고 40℃, 최저 -20℃의 범위를 넘지 않고 24시간 평균 주위

A bushing for anti-pollution type of single bushing pole transformer

ICS
CCS
L17
发布
1998-12-31
实施
1998-12-31

이 규격은 주위 온도가 최고 40℃, 최저 -20℃의 범위를 넘지 않고 24시간 평균 주위

Anti-pollution type of single bushing pole transformer(22.9kV)

ICS
CCS
L17
发布
1998-12-31
实施
1998-12-31