共找到 3934 条与 连接器 相关的标准,共 263 页
Connectors for electronic equipment. Tests and measurements. Signal integrity tests up to 1000 MHz on IEC 60603-7 and IEC 61076-3 series connectors. Tests 28a to 28g
Connectors for electronic equipment - Tests and measurements - Part 24-1 : magnetic interference tests - Test 24a : residual magnetism
Radio-frequency connectors - Part 47: Sectional specification for radio-frequency coaxial connectors with clamp coupling, typically for use in 75
This part of IEC 61169 which is a sectional specification (SS) provides information and rules for the preparation of detail specifications (DS) for RBMA series RF coaxial connectors@ with characteristic impedance of 50 ??@ with threaded coupling and operating frequency limit up to 12@4 GHz@ used in wireless@ microwave@ telecommunication@ and other fields@ connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2@ dimensional details of standard test connectors-grade 0@ gauging information and tests selected from IEC 61169-1@ applicable to all detail specifications relating to RBMA series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
Radio-frequency connectors - Part 43: Sectional specification for RBMA series Blind mating RF coaxial connectors.
Plugs and socket-outlets for household and similar purposes - Part 1: General requirements on fixed socket-outlets
Plugs and socket-outlets for household and similar purposes - Part 2-1: General requirements on Plugs and portable socket-outlets
Connectors for electronic equipment - Product requirements - Part 2-101 : circular connectors - Detail specification for M12 connectors with screw-locking
This part of IEC 60512 specifies the test methods for transmission performance for IEC 60603-7 and IEC 61076-3 series connectors up to 1 000 MHz. It is also suitable for testing lower frequency connectors@ however the test methodology specified in the detailed specification for any given connector remains the reference conformance test for that connector. The test methods provided here are: ?C insertion loss@ test 28a; ?C return loss@ test 28b; ?C near-end crosstalk (NEXT) test 28c; ?C far-end crosstalk (FEXT)@ test 28d; ?C transverse conversion loss (TCL)@ test 28f; ?C transverse conversion transfer loss (TCTL)@ test 28g. For the transfer impedance (ZT) test@ see IEC 60512-26-100@ test 26e. For the coupling attenuation@ see IEC 62153-4-12.
Connectors for electronic equipment - Tests and measurements - Part 28-100: Signal integrity tests up to 1000 MHz on 60603-7 and 61076-3 series connectors - Tests 28a to 28g
Plugs, socket-outlets and couplers for industrial purposes.Part 1: General requirements (IEC 60309-1:1999 + A1:2005, modified + A2:2012); German version EN 60309-1:1999 + A1:2007 + A2:2012
Connectors for photovoltaic systems - Safety requirements and tests; German version EN 50521:2008 + A1:2012
Radio-frequency connectors. Sectional specification for radio-frequency coaxial connectors with clamp coupling, typically for use in 75
Connectors for electronic equipment - Product requirements - Part 3-110 : detail specification for shielded, free and fixed connectors for data transmission with frequencies up to 1 000 MHz
Standard for Safety for Splicing Wire Connectors
Standard for Safety for Single Pole Locking-Type Separable Connectors
Standard for N times 64 kilobit per second optical fiber interfaces between teleprotection and multiplexer equipment
This part of IEC 61169 which is a sectional specification (SS) provides information and rules for the preparation of detail specifications (DS) for TNCA series RF coaxial connectors@ with characteristic impedance of 50 ??@ with threaded coupling and operating frequency limit up to 18 GHz@ used in wireless@ communication@ instrument@ antenna@ test and measurements@ radar@ and other fields@ connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2@ dimensional details of standard test connectors-grade 0@ gauging information and tests selected from IEC 61169-1@ applicable to all detail specifications relating to TNCA series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. TNCA connectors are recommended for applications above 11 GHz. TNCA connectors are compatible with TNC connectors as described in the IEC 60169-17 and IEC 60169-26 provided that the dielectric of connector with socket-centre contact does not extend beyond reference plane. However when mated with these connectors@ the performances are not ensured. NOTE Attention is drawn to the fact that TNCA interface does not utilize overlapping PTFE dielectric for increased voltage breakdown resistance.
Radio frequency connectors - Part 26: Sectional specification for TNCA series RF coaxial connectors
Connectors for electronic equipment - Product requirements - Part 2-101: Circular connectors - Detail specification for M12 connectors with screw-locking (IEC 61076-2-101:2012); German version EN 61076-2-101:2012
This part of IEC 61169@ which is a sectional specification (SS)@ provides information and rules for the preparation of detail specifications (DS) for CQN series RF coaxial connectors@ with characteristic impedance of 50 ??@ with threaded coupling and operating frequency limit up to 11 GHz@ used in wireless@ microwave@ telecommunication@ and other fields@ connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2@ dimensional details of standard test connectors-grade 0@ gauging information and tests selected from IEC 61169-1@ applicable to all detail specifications relating to CQN series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H (see Tables 8 and 9).
Radio-frequency connectors - Part 42: Sectional specification for CQN series quick lock R.F. coaxial connectors
Rework Resistance to Soldering Heat Test Procedure for Electrical Connectors and Sockets
Standard for Safety for Splicing Wire Connectors
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号