This European Standard specifies the requirements for masonry bed joint reinforcement for structural use (see 5.2.1) and for non-structural use (see 5.2.2). Where products are intended for use in cavity wall construction, this European Standard covers only the performance of the meshwork as reinforcement in bed joints and not its performance as wall ties across the cavity. This European Standard is not applicable to: a) products in the form of individual bars or rods; b) products formed from materials other than specified grades of austenitic stainless steel or zinc pre-coated steel sheet or zinc coated steel wire with or without organic coating. NOTE Annex ZA refers only to welded wire meshwork intended for structural use for structural use referred to in 5.2.1 as there are no known regulated requirements for products of this family for non.structural use.

Specification for ancillary components for masonry - Part 3: Bed joint reinforcement of steel meshwork

ICS
91.060.10;91.080.30
CCS
P24
发布
2003-09-16
实施
2003-09-16

The scope of this standard is to specify materials, properties, requirements and methods of testing for precast concrete paving blocks and complementary fittings. This standard is applicable to precast concrete paving blocks for pedestrian and vehicular use e.g. footpaths, precincts, cycle tracks, car parks, roads, highways, industrial areas (including docks and harbours), aircraft pavements, bus stations, petrol filling stations.#,,#

Concrete paving blocks - Requirements and test methods; German version EN 1338:2003

ICS
93.080.20
CCS
P24
发布
2003-08
实施

These test methods are intended to provide simplified and economical means for gathering comparative research data on the flexural bond strength developed with different types of masonry units and mortar or for the purpose of checking job quality control (materials and workmanship). Note 18212;These test methods are not intended for use in establishing design stresses. For this purpose, Methods E 72 should be used. 1.1 These test methods cover determination of the flexural bond strength of unreinforced masonry assemblages. Two procedures are provided: 1.1.1 Test Method A -Simply supported beam with third-point loading. 1.1.2 Test Method B -Simply supported beam with uniform loading. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Flexural Bond Strength of Masonry

ICS
91.060.10 (Walls. Partitions. Facades)
CCS
P24
发布
2003
实施

Repointing masonry improves weather resistance, reduces water penetration, maintains structural and visual integrity, and prolongs the life of the building by allowing a mortar joint to shed water and avoid the accumulation and penetration of rainwater between mortar and masonry units. This guide provides for the selection of the most effective methods appropriate for repointing masonry based upon the following parameters: Determination of joints to be repointed. Evaluation of in-situ masonry. Evaluation of techniques for removal of mortar. Determination of appropriate repointing mortar. Selection of repointing mortar. Establishing the method of execution of the work. Visual inspection of the work.1.1 This guide applies only to existing historic masonry construction. For purposes of this guide historic masonry is intended to refer to buildings that have significant historic, architectural, cultural or social meaning and are constructed of masonry materials. Similar techniques and evaluation should be employed for non-historic masonry, but are not addressed in this guide. 1.2 This guide outlines procedures for repointing historic masonry and is intended to provide guidelines for the user to establish project-specific requirements for repointing of historic masonry. 1.3 This guide only pertains to masonry units: brick, terra cotta, stone, cast stone, and concrete brick laid in mortar, and may or may not be appropriate for other masonry units. 1.4 This guide addresses repointing (tuckpointing) as defined in 3.1.3. 1.5 When considering repointing, especially on masonry of artistic, architectural, cultural, or historical significance, guidance from a specialist experienced in historic masonry and repointing should be sought. 1.6 This guide does not address pointing styles or profiles used on masonry or the methods of producing them. 1.7 Additional repairs that may impact the structural integrity of the masonry may necessitate that a structural stability analysis be completed prior to the execution of any work. 1.8 Following this guide may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

Standard Guide for Repointing (Tuckpointing) Historic Masonry

ICS
91.080.30 (Masonry)
CCS
P24
发布
2003
实施

1.1 This practice covers the proper methods of installing vitrified clay pipe lines in order to fully utilize the structural properties of such pipe.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Practice for Installing Vitrified Clay Pipe Lines

ICS
23.040.01 (Pipeline components in general. Pipelin
CCS
P24
发布
2003
实施

Methods of test for masonry units - Part 5 : determination of the active soluble salts content of clay masonry units.

ICS
91.100.25
CCS
P24
发布
2002-11-01
实施
2002-11-05

Methods of test for masonry units - Part 14 : determination of moisture movement of aggregate concrete and manufactured stone masonry units.

ICS
91.100.30
CCS
P24
发布
2002-10-01
实施
2002-10-20

This European Standard gives procedures for the determination of design thermal values (thermal resistance and/or thermal conductivity) of masonry and masonry products.

Masonry and masonry products - Methods for determining design thermal values

ICS
91.080.30;91.120.10
CCS
P24
发布
2002-06-27
实施
2002-06-27

Methods of test for masonry units - Determination of the active soluble salts content of clay masonry units

ICS
91.100.25
CCS
P24
发布
2002-03-14
实施
2002-03-14

The document specifies a method for determining the active soluble salts content of clay masonry units.

Methods of test for masonry units - Part 5: Determination of the active soluble salts content of clay masonry units; German version EN 772-5:2001

ICS
91.100.15
CCS
P24
发布
2002-03
实施

Methods of test for masonry units - Part 14: Determination of moisture movement of aggregate concrete and manufactured stone masonry units; German version EN 772-14:2001

ICS
91.100.30
CCS
P24
发布
2002-02
实施

This European Standard specifies a method of determining the bending tensile strength of aggregate concrete masonry units having a width less than 100 mm and a ratio of length to width greater than 10.

Methods of test for masonry units - Part 6: Determination of bending tensile strength of aggregate concrete masonry units; German version EN 772-6:2001

ICS
91.100.30
CCS
P24
发布
2002-02
实施

This European Standard specifies a method of measuring the moisture movement of aggregate concrete and manufactured stone masonry units between two specified extreme moisture conditions.

Methods of test for masonry units - Determination of moisture movement of aggregate concrete and manufactured stone masonry units

ICS
91.100.30
CCS
P24
发布
2002-01-31
实施
2002-01-31

This European Standard specifies methods for determining the load capacity and load-deflection characteristics of restraint straps fixed to timber joists, rafters and timber wall plates and masonry walls.

Methods of test for ancillary components for masonry - Determination of load capacity and load-deflection characteristics of straps

ICS
91.080.30
CCS
P24
发布
2002-01-31
实施
2002-01-31

1.1 This terminology covers generic terms and generic definitions of terms specifically associated with masonry.

Standard Terminology of Masonry

ICS
01.040.91 (Construction materials and building (Vo
CCS
P24
发布
2002
实施

1.1 These test methods cover the evaluation of flexural bond strength, normal to the bed joints, of masonry built of manufactured masonry units, as determined in accordance with Test Method C 1072. Sampling and testing procedures are referenced, and terms are defined. Two different test methods are specified, each for a different purpose:1.1.1 The first test method is the "Test Method for Laboratory-Prepared Specimens." Its purpose is to compare the bond strengths (under the given conditions) of masonry mortars. It could be used, for example, to check the quality of mortar products after production, or to indicate the bond strength (under the given conditions) of a mortar product without requiring the product to be tested in combination with many different units. It is not intended to represent field conditions. It uses standard concrete masonry units. Mortars are batched by weight equivalents of volume proportions and are mixed to a prescribed flow. Prisms are constructed using a jig and are bag-cured. Note 18212;Standard fired clay masonry units are under development but are not now available. When their development is complete, they will be incorporated into these test methods.1.1.2 The second test method is the "Test Method for Field-Prepared Specimens." Its purpose is to evaluate the bond strength (under the given conditions) of a particular unit-mortar combination, either for preconstruction evaluation of materials or for quality control purposes during construction. Mortars are batched conventionally, and the flow is not prescribed. Prisms are constructed conventionally (no jig) and are bag-cured.1.1.3 The two test methods are not consistent, nor are they intended to be. They are intended to be used for two different purposes. To make this clear, the two methods are presented separately.1.1.4 Appendix X1 suggests two possible criteria for assessing the bond strength values obtained using these test methods. These possible evaluation criteria are given for illustration only and are not mandatory.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Evaluating Masonry Bond Strength

ICS
91.080.30 (Masonry)
CCS
P24
发布
2002
实施

1.1 This test method covers procedures for masonry prism construction and testing, and procedures for determining the compressive strength of masonry, f''mt'', used to determine compliance with the specified compressive strength of masonry, f `m''. When this test method is used for research purposes, the construction and test procedures within serve as a guideline and provide control parameters.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Compressive Strength of Masonry Prisms

ICS
19.060 (Mechanical testing); 91.080.30 (Masonry)
CCS
P24
发布
2002
实施

1.1 This test method covers procedures for masonry prism construction and testing, and procedures for determining the compressive strength of masonry, f''mt'', used to determine compliance with the specified compressive strength of masonry, f `m''. When this test method is used for research purposes, the construction and test procedures within serve as a guideline and provide control parameters.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Method for Compressive Strength of Masonry Prisms

ICS
19.060 (Mechanical testing); 91.080.30 (Masonry)
CCS
P24
发布
2002
实施

Methods of test for ancillary components for masonry - Determination of resistance to impact, abrasion and corrosion of organic coatings

ICS
91.080.30
CCS
P24
发布
2001-12-13
实施
2001-12-13

Methods of test for masonry units - Determination of bending tensile strength of aggregate concrete masonry units

ICS
91.100.30
CCS