Q14 混凝土制品 标准查询与下载



共找到 1595 条与 混凝土制品 相关的标准,共 107

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 A complete metric companion to Specification C655 has been developed—Specification C655M; therefore, no metric equivalents are presented in this specification. Note 1—Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 This specification is the inch-pound companion to C506M; therefore, no SI equivalents are presented in the specification.Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C14. Note 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.

Standard Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe 40;Metric41;

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This covers nonreinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 A complete metric companion to Specification C14 has been developed—C14M; therefore, no metric equivalents are presented in this specification. Note 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load conditions and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of pipe specified and provide for or require inspection at the construction site.

Standard Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the construction of pressure pipelines with low internal hydrostatic heads generally not exceeding 125 ft. 1.2 This specification is the inch-pound companion to Specification C361; therefore, no SI equivalents are presented in the specification.Note 1—Field tests on completed portions of the pipeline are not covered by this specification for the manufacture of the pipe but should be included in specifications for pipe laying.

Standard Specification for Reinforced Concrete Low-Head Pressure Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage. 1.2 This specification is the companion to SI Specification C1433M; therefore, no SI equivalents are shown in this specification. Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the box section specified, and provision for inspection at the construction site, are required.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the construction of pressure pipelines with low internal hydrostatic heads generally not exceeding 125 ft. 1.2 This specification is the inch-pound companion to Specification C361; therefore, no SI equivalents are presented in the specification.Note 1—Field tests on completed portions of the pipeline are not covered by this specification for the manufacture of the pipe but should be included in specifications for pipe laying.

Standard Specification for Reinforced Concrete Low-Head Pressure Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used for the construction of culverts and for the conveyance of storm water. 1.2 A complete metric companion to Specification C1504 has been developed—C1504M; therefore, no metric equivalents are presented in this specification.Note 1—This specification is primarily a manufacturing and purchasing specification. The successful performance of this product depends upon the proper selection of the geometric section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete three-sided structure specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the geometric section specified and provisions for inspection at the construction site are required. 1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes and sewage.Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs per the AASHTO LRFD Bridge Design Specifications are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the box section specified, and provision for inspection at the construction site, are required. 1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers Designed According to AASHTO LRFD

ICS
91.100.30 (Concrete and concrete products); 93.030
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the construction of pressure pipelines with low internal hydrostatic heads generally not exceeding 375 kPa. 1.2 This specification is the SI companion to Specification C361. It is compatible in technical content.Note 1—Field tests on completed portions of the pipeline are not covered by this specification for the manufacture of the pipe but should be included in specifications for pipe laying.

Standard Specification for Reinforced Concrete Low-Head Pressure Pipe 40;Metric41;

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2 This specification is the SI companion to Specification C76. Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, controlled manufacture in the plant, and care and installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.Note 2—Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (ASTM Designation C655M).

Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe 40;Metric41;

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2 Pipe designed for placement with the major axis horizontal shall be designated as “Horizontal Elliptical Pipe.” Pipe designed for placement with the major axis vertical shall be designated as “Vertical Elliptical Pipe.” 1.3 This specification is the inch-pound companion to Specification C507M; therefore, no SI equivalents are presented in the specification. Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced elliptically shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 Pipe designed for placement with the major axis horizontal shall be designated as “Horizontal Elliptical Pipe.” Pipe designed for placement with the major axis vertical shall be designated as “Vertical Elliptical Pipe.” 1.3 This specification is the SI companion to Specification C507. Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

Standard Specification for Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe 40;Metric41;

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced concrete pipe designed for specific D-loads and intended to be used for the conveyance of sewage, industrial wastes, and storm water and for the construction of culverts. 1.2 This specification is the metric counterpart of Specification C655. Note 1—Experience has shown that the successful performance of this product depends upon the proper selection of the pipe strength, the type of bedding and backfill, the care that the installation conforms to the construction specifications, and provision for adequate inspection at the construction site. This specification does not include requirements for bedding, backfill, the relationship between field load conditions and the strength designation of pipe, or durability under unusual environmental conditions. These requirements should be included in the project specification.

Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe 40;Metric41;

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1  This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2 This specification is the inch-pound companion to Specification C76M; therefore, no SI equivalents are presented in this specification. Reinforced concrete pipe that conform to the requirements of C76M, are acceptable under this Specification C76 unless prohibited by the Owner.Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.Note 2—Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (Specification C655).

Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage. 1.2 This specification is the SI companion to Specification C1433.Note 1—This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the box section specified and provide for inspection at the construction site.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers 40;Metric41;

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. 1.2 This specification is the SI companion to Specification C506. Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe 40;Metric41;

ICS
23.040.50 (Pipes and fittings of other materials)
CCS
Q14
发布
2014
实施

1.1 This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: (1) normal weight, (2) medium weight, and (3) lightweight. These units are suitable for both loadbearing and nonloadbearing applications. 1.2 Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both.Note 1—The requirements of this specification have been researched, evaluated, and established for over a century, resulting in the physical properties and attributes defined here. These requirements are uniquely and solely applicable to concrete masonry units manufactured on equipment using low or zero slump concrete and the constituent materials defined herein. Many performance attributes of concrete masonry units are indirectly accounted for, or inherently reflected within, the requirements of this specification without direct measurement, assessment, or evaluation. Applying the requirements of this specification to products that may be similar in appearance, use, or nature to those covered by this specification may not address all pertinent physical properties necessary to ensure performance or serviceability of the resulting construction in real-world applications under typical exposure environments. Products manufactured using alternative materials, manufacturing methods, or curing processes not covered by this specification should not be evaluated solely using the requirements in this specification; however, developers of new products can consider the property requirements of this specification as a beginning benchmark for unit performance. It is reasonable to test new products for system performance as well as unit performance. 1.3 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.Note 2—When particular features are desired such as surface textures for appearance or bond, finish, color, or particular properties such as density classification, higher compressive strength, fire resistance, thermal performance or acoustical performance, these features should be specified separately by the purchaser. Suppliers should be consulted as to the availability of units having the desired features.

Standard Specification for Loadbearing Concrete Masonry Units

ICS
91.100.30 (Concrete and concrete products)
CCS
Q14
发布
2014
实施

이 표준은 압축 하중으로 인한 콘크리트 원주 공시체의 크리프를 측정하는 방법에 대하여 규정한다.

Standard test method for creep of concrete in compression

ICS
91.100.30
CCS
Q14
发布
2013-12-09
实施
2013/12/9

이 표준은 콘크리트의 원주형 및 각주형 공시체의 종 진동, 변형 진동 및 비틀림 진동의 1차 공명진동수를 구하여, 여기에서 동 탄성 계수, 동 전단 탄성 계수 및 동 푸아송비를 구하는 시험에 대하여 규정한다.

Standard test method for dynamic modulus of elasticity, rigidity and dynamic Poisson’s ratio of concrete specimens by resonance vibration

ICS
91.100.30
CCS
Q14
发布
2013-12-09
实施
2013/12/9



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号