共找到 26 条与 相关的标准,共 2 页
This document specifies a method for evaluating the thermo-physiological impact of protective fabric ensembles and potentially protective clothing ensembles in a simulated activity under defined relevant conditions for firefighters. This document is intended to be used to assess the thermo-physiological impact of protective fabric ensembles and potentially protective clothing ensembles but not the risk for heat stress due to actual fire conditions. The results of this test method can be used as elements of characterisation and comparison of thermo-physiological impact of various types of protective fabric ensembles and potentially protective clothing ensembles. Default measurements are undertaken on fabric samples representing the garment or protective clothing combination. Optionally and in addition to the standard test method, the same testing protocol can be applied to characterise protective clothing ensembles including underwear, air layers and certain design features4). In addition measurements on readymade garments are optionally possible. NOTE The presently used evaluation methods are only validated for structural firefighting garments.
Protective clothing for firefighters - Physiological impact - Part 2: Determination of physiological heat load caused by protective clothing worn by firefighters
Protective clothing - Protection against flame - Method of test for limited flame spread (ISO 15025:2016); German version EN ISO 15025:2016
Respiratory equipment - Compressed gases for breathing apparatus; German version EN 12021:2014
Respiratory protective devices - Methods of test - Part 7 : determination of particle filter penetration.
Respiratory protective devices - Gas filter(s) and combined filter(s) - Requirements, testing, marking.
Respiratory protective devices - Gas filter(s) and combined filter(s) - Requirements, testing, marking.
The project applies for gasfilters and combinationfilters as parts of respiratory protective devices without air supply (short: CO-filters and combined CO-filters).
Respiratory protective devices - Gas filter(s) and combined filter(s) for protection against carbon monoxide - Requirements, testing, marking
Respiratory protective devices - Particle filters - Requirements, testing, marking.
Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governed demand valve for escape purposes only.
Respiratory protective devices - Lung governed demand self-contained open-circuit compressed air breathing apparatus with full face mask or mouthpiece assembly for escape - Requirements, testing, marking.
Respiratory protective devices - Gas cylinder valves - Part 1 : thread connections for insert connector.
This European Standard is applicable to a thread connection used for the connection between a gas cylinder valve and a pressure reducer for respiratory equipment for diving containing breathable nitrox gas with an oxygen content greater than 22 % or oxygen. This European Standard specifies the dimensions and tolerances for connections which are used for respiratory equipment.
Respiratory protective devices - Gas cylinder valves - Outlet connections for diving gases Nitrox and oxygen
Respiratory protective devices - Methods of test - Part 6 : determination of carbon dioxide content of the inhalation air.
Provides performance and marking requirements and test methods for filtering half masks for protection of the respiratory tract against particles.
Respiratory protective devices - Filtering half masks to protect against particles - Requirements, testing, marking
This European Standard applies to the connection between a gas cylinder valve and a gas cylinder for respiratory protective devices. It specifies the dimensions and tolerances for thread connections to be used for respiratory protective devices and contains requirements for impact resistance for the connection between a gas cylinder and a gas cylinder valve.
Respiratory protective devices - Gas cylinder valves - Thread connections for insert connector
The document specifies minimum requirements for self-contained closed-circuit breathing apparatus, compressed oxygen (O) and compressed oxygen-nitrogen (O - N) type, used as respiratory protective devices, except escape apparatus and diving apparatus.#,,#
Respiratory protective devices - Self-contained closed-circuit breathing apparatus compressed oxygen or compressed oxygen-nitrogen type - Requirements, testing, marking (includes Amendment A1:2000); German version EN 145:1997 + A1:2000
Respiratory equipment - Open-circuit self-contained compressed air diving apparatus - Requirements, testing, marking.
This European Standard is applicable to standard threads for respiratory protective devices. This standard does not apply to diving equipment and to positive pressure demand breathing apparatus.
Respiratory protective devices: threads for facepieces - Standard thread connection
For facepieces in positive pressure breathing apparatus.
Respiratory protective devices: threads for facepieces - Thread connection M 45 x 3
Does not apply to diving equipment or to positive pressure demand breathing apparatus.
Respiratory protective devices: threads for facepieces - Centre thread connection
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号