13.220.20;29.060.20;45.060.01 标准查询与下载



共找到 23 条与 相关的标准,共 2

Railway applications. Railway rolling stock cables having special fire performance. Guide to use

ICS
13.220.20;29.060.20;45.060.01
CCS
K15
发布
2013-09-30
实施
2013-09-30

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables; German version EN 50264-3-2:2008

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2009-03
实施
2009-03-01

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements; German version EN 50264-1:2008

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2009-03
实施
2009-03-01

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables; German version EN 50264-2-1:2008

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2009-03
实施
2009-03-01

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables; German version EN 50264-3-1:2008

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2009-03
实施
2009-03-01

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables; German version EN 50264-2-2:2008

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2009-03
实施
2009-03-01

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1 : general requirements.

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2008-11-01
实施
2008-11-08

EN 50264-3-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2); • 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2); • 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2); • 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90° C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-3-1 should be read in conjunction with Part 1 “General requirements”.

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions — Single core cables

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2008-08-29
实施
2008-08-29

EN 50264-2-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm², 1,5 mm² and 2,5 mm², number of cores from 2 to 40); • 0,6/1 kV screened or unscreened (1,5 mm² to 50 mm², 2, 3 and 4 cores). NOTE Not all conductor sizes or number of cores are specified for every type. All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-2 should be read in conjunction with Part 1 “General requirements”.

Railway applications. Railway rolling stock power and control cables having special fire performance. Cables with crosslinked elastomeric insulation. Multicore cables

ICS
13.220.20;29.060.20;45.060.01
CCS
S35;K13
发布
2008-08-29
实施
2008-08-29

EN 50264-3-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm2, 1,5 mm2 and 2,5 mm2, number of cores from 2 to 40); • 0,6/1 kV screened or unscreened, (1,5 mm2 to 50 mm2, 2, 3 and 4 cores). NOTE Not all conductor sizes or number of cores are specified for every type. All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-3-2 should be read in conjunction with Part 1 “General requirements”.

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions — Multicore cables

ICS
13.220.20;29.060.20;45.060.01
CCS
S35;K13
发布
2008-08-29
实施
2008-08-29

EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: • 0,6/1 kV unscreened, unsheathed (1 mm² to 400 mm²); • 1,8/3 kV unscreened, unsheathed (1,5 mm² to 400 mm²); • 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); • 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.

Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation — Single core cables

ICS
13.220.20;29.060.20;45.060.01
CCS
K13
发布
2008-08-29
实施
2008-08-29

Railway applications - Railway rolling stock cables having special fire performance - Thin wall and standard wall - Guide to use; German version EN 50355:2003

ICS
13.220.20;29.060.20;45.060.01
CCS
S35
发布
2004-06
实施
2004-06-01

Railway applications - Railway rolling stock cables having special fire performance - Thin wall and standard wall - Guide to use.

ICS
13.220.20;29.060.20;45.060.01
CCS
S80
发布
2004-01-01
实施
2004-01-20

This European Standard gives guidance in the safe use of rolling stock cables specified in EN 50264 and EN 50306. NOTE EN 50355 will be extended in future to cover also EN 50382, which is currently under preparation. These cables should only be used for the wiring of railway rolling stock and within the limits given in the manner described in this European Standard. All these cables are for fixed installation where there is no free movement of cable, except for stresses due to typical service. This European Standard is to be applied in conjunction with the relevant product and installation standards. Stricter requirements than those given in this standard could be necessary; see in particular EN 50343. This European Standard is not applicable to - intercarriage jumpers, - cables subject to continual flexing, - pantograph cables, - coaxial and fibre optic cables, - wire wrap, - cables rated at voltages greater than 3,6/6 kV, - national types, - applications other than the cabling of railway rolling stock. Legal or statutory requirements do take precedence over the guidance given in this document. In cases where no guidance exists or where it cannot be derived from general information, it is recommended that advice should be sought from the cable manufacturer.

Railway applications - Railway rolling stock cables having special fire performance - Thin wall and standard wall - Guide to use

ICS
13.220.20;29.060.20;45.060.01
CCS
S35
发布
2003-10-31
实施
2003-10-31

Railway applications - Railway rolling stock cables having special fire performance; Standard wall - Part 3: Multicore cables; German version EN 50264-3:2002

ICS
13.220.20;29.060.20;45.060.01
CCS
S34
发布
2003-06
实施
2003-06-01

Railway applications - Railway rolling stock cables having special fire performance; Standard wall - Part 2: Single core cables; German version EN 50264-2:2002

ICS
13.220.20;29.060.20;45.060.01
CCS
S34
发布
2003-06
实施
2003-06-01

Railway applications - Railway rolling stock cables having special fire performance; Standard wall - Part 1: General requirements; German version EN 50264-1:2002

ICS
13.220.20;29.060.20;45.060.01
CCS
S34
发布
2003-06
实施
2003-06-01

Railways applications - Railway rolling stock cables having special fire performance - Standard wall - Part 1 : general requirements.

ICS
13.220.20;29.060.20;45.060.01
CCS
S80
发布
2002-12-01
实施
2002-12-05

Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 3 : multicore cables.

ICS
13.220.20;29.060.20;45.060.01
CCS
S80
发布
2002-12-01
实施
2002-12-05

To be read in conjunction with BS EN 50264-1:2002

Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Single core cables

ICS
13.220.20;29.060.20;45.060.01
CCS
S35
发布
2002-10-11
实施
2002-10-11



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号