This part of IEC 60331 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. This document is applicable to cables of rated voltage not exceeding 600 V/1000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables. It is intended for use when testing cables of not greater than 20 mm overall diameter. Cables of larger diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-1. This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-2. Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used. Annex A provides the method of verification of the burner and control system used for the test. Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this standard. CAUTION - The test given in this standard may involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risk of shock, burning, fire and explosion that may be involved, and against any noxious fumes that may be produced.

Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2018-03-01
实施

This part of IEC 60331 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. This document is applicable to cables of rated voltage not exceeding 600 V/1000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables. It is intended for use when testing cables of greater than 20 mm overall diameter. Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-2. This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1. Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used. Annex A provides the method of verification of the burner and control system used for the test. Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this document. CAUTION - The test given in this standard may involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risk of shock, burning, fire and explosion that may be involved, and against any noxious fumes that may be produced.

Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2018-03-01
实施
2018-03-30

Tests for electric cables under fire conditions — Circuit integrity — Part 21: Procedures and requirements — Cables of rated voltage up to and including 0.6/1.0 kV

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2015-08-04
实施

Test on gases evolved during combustion of materials from cables. Determination of acidity (by pH measurement) and conductivity

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2014-05-31
实施
2014-05-31

Test on gases evolved during combustion of materials from cables. Determination of the halogen acid gas content

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2014-05-31
实施
2014-05-31

이 표준은 규정된 조건하에서 연소하는 케이블로부터 방출되는 연기의 밀도를 측정하기 위한 시험절차를 제시한다. 이 부에서는 시험을 위한 케이블을 준비 및 조립하는 방법, 케이블을 연소 시키는방법을 설명하며, 시험 결과를 평가하는 데 권장되는 요구사항을 제공한다.

Measurement of smoke density of cables burning under defined conditions-Part 2:Test procedure and requirements

ICS
13.220.40;29.020;29.060.20
CCS
K04
发布
2013-09-18
实施
2013-09-18

Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2013-06
实施
2013-06-29

Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2013-06
实施
2013-06-25

Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2013-06
实施

Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which a

Tests for electric cables under fire conditions - Circuit integrity Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-09-04
实施

Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV and control cables with a rated voltage which a

Tests for electric cables under fire conditions - Circuit integrity Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-09-04
实施

Specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV, and control cables with a rated voltage which

Tests for electric cables under fire conditions - Circuit integrity Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-09-04
实施

Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-07
实施

This part of IEC 60331 specifies the test procedure and gives the performance requirement@ including a recommended flame application time@ for cables of rated voltage up to and including 0@6/1@0 kV required to maintain circuit integrity when subjected to fire and mechanical shock under specified conditions. It is intended for use when testing cables of greater than 20 mm overall diameter. It describes the means of sample preparation@ the continuity checking arrangements@ the electrical testing procedure@ the method of burning the cables and the method of shock production@ and gives requirements for evaluating test results. This part of IEC 60331 is applicable to low-voltage power cables@ and control cables with a rated voltage. NOTE Although the scope is restricted to cables with rated voltage up to and including 0@6/1@0 kV@ the procedure may be used@ with the agreement of the manufacturer and the purchaser@ for cables with rated voltage up to and including 3@3 kV@ provided that suitable fuses are used.

Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-05
实施
2018-03-30

This part of IEC 60331 specifies the test apparatus to be used for testing cables required to maintain circuit integrity when subject to fire and mechanical shock where the test condition is based upon a flame with a controlled heat output corresponding to a temperature of a nominal 850 ?? It is intended for use when testing cables of greater than 20 mm overall diameter.It also provides@ in annex A@ the method of verification of the burner and control system used for the test.

Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-05
实施
2018-03-30

This part of IEC 60331 specifies the test apparatus to be used for testing cables required to maintain circuit integrity when subject to fire and mechanical shock where the test condition is based upon a flame with a controlled heat output corresponding to a temperature of a nominal 850 ?? It is intended for use when testing cables of greater than 20 mm overall diameter.It also provides@ in annex A@ the method of verification of the burner and control system used for the test.

Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-05
实施
2018-03-30

This part of IEC 60331 specifies the test apparatus to be used for testing cables required to maintain circuit integrity when subject to fire alone where the test condition is based upon a flame with a controlled heat output corresponding to a temperature of at least 750 ??It also provides in annex A the method of verification of the burner and control system used for the test.

Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C; Amendment 1

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2009-05
实施
2009-07-13

이 표준은 전기 케이블이나 광케이블을 규정된 조건하에서 연소시킬 때, 예를 들어 몇 개의

Measurement of smoke density of cables burning under defined conditions-Part 1:Test apparatus

ICS
13.220.40;29.020;29.060.20
CCS
N20
发布
2008-11-20
实施
2008-11-20

この規格は,垂直に布設した一条の絶縁電線,ケーブル又は光ファイバケーブルが限定された燃焼条件での燃焼落下物(粒子)の測定方法について規定する。

Tests on electric and optical fibre cables under fire conditions -- Part 1-3: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for determination of flaming droplets/particles

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2007-07-20
实施

この規格は,垂直に布設した一条の絶縁電線,ケーブル又は光ファイバケーブルが火災によって,垂直方向に延焼するときの難燃性を試験する方法について規定する。

Tests on electric and optical fibre cables under fire conditions -- Part 1-2: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame

ICS
13.220.40;29.020;29.060.20
CCS
K13
发布
2007-07-20
实施