Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders

ICS
13.220.40;71.040.10
CCS
发布
2007-01-31
实施
2007-01-31

This European standard is a product specification, giving performance requirements for fire safety cabinets used for storing pressurised gas cylinders. It is applicable to cabinets with a total internal volume suitable to store pressurised gas cylinders with a total volume not exceeding 220 l, including cylinders of purging gases. This standard is not applicable to brick enclosures, walk-in storage rooms or cabinets which do not take their weight on their base. Requirements are given in respect to the construction of the cabinet and its capacity to resist fire conditions on the outside. A type test is included, which is based on the already existing fire resistance (heating curve) tests given in EN 14470-1. The tests described in this European Standard are type tests (for the storage of flammable liquids EN 14470-1 is applicable – the criteria for failure are different – see Annex A).

Fire safety storage cabinets — Part 2: Safety cabinets for pressurised gas cylinders

ICS
13.220.40;71.040.10
CCS
C80
发布
2007-01-31
实施
2007-01-31

Fire safety storage cabinets - Safety cabinets for pressurised gas cylinders

ICS
13.220.40;71.040.10
CCS
发布
2007-01-31
实施
2007-01-31

Fire safety storage cabinets - Part 2 : safety cabinets for pressurised gas cylinders.

ICS
13.220.40;71.040.10
CCS
J74
发布
2006-12-01
实施
2006-12-05

This European Standard is a product specification, giving performance requirements for fire safety cabinets used for storing pressurised gas cylinders. It is applicable to cabinets with a total internal volume suitable to store pressurised gas cylinders with a total volume not exceeding 220 l, including cylinders of purging gases. NOTE 1 This means that up to four gas cylinders of 50 l or up to three gas cylinders of 70 l can be stored in a single cabinet. NOTE 2 It is intended that the pressurised gas cylinders can be in use while in the cabinet. NOTE 3 Attention is drawn to national regulations which can apply with regard to the storage and use of pressurised gas cylinders. NOTE 4 The sagety cabinet can be free standing, restrained to a wall or mounted on wheels or castors. This standard is not applicable to brick enclosure, walk-in storage rooms or cabinets which do not take their weight on their base. Requirements are given in respect to the construction of the cabinet and its capacity to resist fire conditions on the outside. A type test is included, which is based on the already existing fire resistance (heating curve) tests given in EN 14470-1. The tests described in this European Standard are type tests (for the storage of flammable liquids EN 14470-1 is applicable - the criteria for failure are different - see Annex A).

Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders; English version of DIN EN 14470-2:2006-11

ICS
13.220.40;71.040.10
CCS
C80;N61
发布
2006-11
实施
2006-11-01

This European standard is a product specification, giving performance requirements for fire safety cabinets used for storing pressurised gas cylinders. It is applicable to cabinets with a total internal volume suitable to store pressurised gas cylinders with a total volume not exceeding 220 l, including cylinders of purging gases. This standard is not applicable to brick enclosures, walk-in storage rooms or cabinets which do not take their weight on their base. Requirements are given in respect to the construction of the cabinet and its capacity to resist fire conditions on the outside. A type test is included, which is based on the already existing fire re

Fire safety storage cabinets - Part 2: Safety cabinets for pressurised gas cylinders

ICS
13.220.40;71.040.10
CCS
发布
2006-08-01
实施

This European Standard is a product specification, giving performance requirements for fire safety cabinets to be used for the storage of flammable liquids in laboratories. It is applicable to cabinets with a total internal volume of not greater than 1 m, which may be free standing, restrained to a wall or mounted on wheels or castors. It is not applicable to brick enclosures or walk-in storage rooms. This European Standard is not applicable to cabinets which do not take their weight on their base. Requirements are given in respect of the construction of the cabinet and its capacity to resist fire conditions on the outside. A classification of cabinets is given, according to the level of fire resistance offered, and a type test is included, which draws on already existing fire resistance tests, such as those given in ISO 834-1 [1] and EN 1363-1. The tests described in this European Standard are type tests. NOTE 1 This European Standard does not discriminate between different flammable liquids, which may have considerably different physical properties. The suitability of the standard in respect of any given flammable liquid should be ascertained by the user. NOTE 2 Attention is drawn to national regulations which may apply with regard to the storage of flammable liquids.

Fire safety storage cabinets - Safety storage cabinets for flammable liquids

ICS
13.220.40;71.040.10
CCS
C85
发布
2004-10-11
实施
2004-10-11

Fire safety storage cabinets - Part 1 : safety storage cabines for flammable liquids.

ICS
13.220.40;71.040.10
CCS
N64
发布
2004-10-01
实施
2004-10-20

Fire safety storage cabinets - Part 1: Safety storage cabinets for flammable liquids

ICS
13.220.40;71.040.10
CCS
发布
2004-08-30
实施
2004-08-30

The European Standard specifies classification, safety requirements and their testing, marking and requirements to the user information of safety cupboards up to 1 cubicmeter volume for the storage of flammabe liquids in laboratories and other working rooms.

Fire safety storage cabinets - Part 1: Safety storage cabinets for flammable liquids; German version EN 14470-1:2004

ICS
13.220.40;71.040.10
CCS
C82
发布
2004-07
实施
2004-07-01

This European Standard is a product specification, giving performance requirements for fire safety cabinets to be used for the storage of flammable liquids in laboratories. It is applicable to cabinets with a total internal volume of not greater than 1 m3, which may be free standing, restrained to a wall or mounted on wheels or castors. It is not applicable to brick enclosures or walk-in storage rooms.This European Standard is not applicable to cabinets which do not take their weight on their base.Requirements are given in respect of the construction of the cabinet and its capacity to resist fire conditions on the outside. A classification of cabinets is gi

Fire safety storage cabinets - Part 1: Safety storage cabinets for flammable liquids

ICS
13.220.40;71.040.10
CCS
发布
2004-04-01
实施