共找到 66 条与 相关的标准,共 5 页
This European Standard specifies sound dose measurement, and the alerts associated, to reduce the risk of listeners developing hearing impairment when using a Personal Music Player (PMP). The standard does not cover exposure from other sources than PMPs.
Sound system equipment: headphones and earphones associated with personal music players - maximum sound pressure level measurement methodology - Part 3: measurement method for sound dose management; German version EN 50332-3:2017
Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique (IEC 61094-3:2016 + COR1:2016); German version EN 61094-3:2016 + AC:2017-01
Sound system equipment: headphones and earphones associated with personal music players. Maximum sound pressure level measurement methodology. Measurement method for sound dose management
Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison (IEC 61094-5:2016); German version EN 61094-5:2016
Electroacoustics. Measurement microphones. Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 2: Matching of sets with headphones if either or both are offered separately, or are offered as one packa
Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 1: General method for "one package equipment"; German version EN 50332-1:2013
Le présent amendement modifie les articles 14 et 17, et l'annexe B de la NF EN 60268-5 et ajoute également une annexe D.
Sound system equipment - Part 5 : loudspeakers
Le domaine d'application de la présente Norme européenne est d'établir une méthode de mesure adaptée, permettant l'évaluation exacte du niveau de pression acoustique maximal, produit par les casques et écouteurs associés aux baladeurs.
Sound system equipment : headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 1 : general method for "one package equipment"
Microphones and earphones for speech communications
Sound system equipment: Headphones and earphones associated with personal music players. Maximum sound pressure level measurement methodology. Matching of sets with headphones if either or both are offered separately, or are offered as one package equipme
Sound system equipment: Headphones and earphones associated with personal music players. Maximum sound pressure level measurement methodology. General method for "one package equipment"
Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison (IEC 61094-8:2012); German version EN 61094-8:2012 + AC:2013
Electroacoustics. Measurement microphones. Methods for free-field calibration of working standard microphones by comparison
This part of the IEC 61094 series is applicable to working standard microphones meeting the requirements of IEC 61094-4. It describes methods of determining the free-field sensitivity by comparison with a laboratory standard microphone or working standard microphone (where applicable) that has been calibrated according to either: ?? IEC 61094-3@ ?? IEC 61094-2 or IEC 61094-5@ and where factors given in IEC/TS 61094-7 have been applied@ ?? IEC 61094-6@ ?? this part of IEC 61094. Methods performed in an acoustical environment that is a good approximation to an ideal free-field (e.g. a high quality free-field chamber)@ and methods that use post processing of results to minimise the effect of imperfections in the acoustical environment@ to simulate freefield conditions@ are both covered by this part of IEC 61094. Comparison methods based on the principles described in IEC 61094-3 are also possible but beyond the scope of this part of IEC 61094. NOTE 1 This part of IEC 61094 is also applicable to laboratory standard microphones meeting the requirements of IEC 61094-1@ noting that these microphones also meet the electroacoustic specifications for working standard microphones. NOTE 2 This part of IEC 61094 is also applicable to combinations of microphone and preamplifier where the determined sensitivity is referred to the unloaded output voltage of the preamplifier. NOTE 3 Other devices@ for example@ sound level meters can be calibrated using the principles of this part of IEC 61094@ but are not within the scope of this standard.
Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison
Subscriber loudspeakers. General specifications
State system for ensuring the uniformity of measurements. Measurement microphones. Part 7. Values for difference between free-field and pressure sensitivity levels of laboratory standard microphones
Specifies mechanical dimensions and certain electroacoustical characteristics for working standard microphones used in measuring systems for the determination of sound pressure to enable these microphones to be used as transfer standards in the calibrati
Measurement microphones Part 4: Specifications for working standard microphones
Specifies a primary method of determining the free-field sensitivity so as to establish a reproducible and accurate basis for the measurement of sound pressure under free-field conditions.
Measurement microphones Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
Gives guidelines for the design of actuators for microphones equipped with electrically conductive diaphragms. Gives methods for the validation of electrostatic actuators and gives a method for determining the electrostatic actuator response of a microph
Measurement microphones Part 6: Electrostatic actuators for determination of frequency response
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved