Electricity metering equipment (a.c.) - Particular requirements - Part 24: Static meters for reactive energy at fundamental frequency (classes 0,5 S, 1 S and 1)

ICS
17.220.20;91.140.50
CCS
N22
发布
2016-11
实施

At the end of the clause, add the following: The safety aspect is covered by IEC 62052-31:2015.

Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 11: Metering equipment; Amendment 1

ICS
17.220.20;91.140.50
CCS
N22
发布
2016-11
实施
2016-11-24

After the dashed items list, add the following: The safety aspect is covered by IEC 62052-31:2015. Replace the penultimate paragraph by: Regarding acceptance tests, see IEC 62058-11:2008 and IEC 62058-21:2008.

Electricity metering equipment (a.c.) - Particular requirements - Part 11: Electromechanical meters for active energy (classes 0,5, 1 and 2); Amendment 1

ICS
17.220.20;91.140.50
CCS
N22
发布
2016-11
实施
2016-11-22

After the dashed items list, add the following: The safety aspect is covered by IEC 62052-31:2015. Replace the penultimate paragraph by the following: Regarding acceptance tests, see IEC 62058-11:2008 and IEC 62058-31:2008.

Electricity metering equipment (a.c.) - Particular requirements - Part 21: Static meters for active energy (classes 1 and 2); Amendment 1

ICS
17.220.20;91.140.50
CCS
N22
发布
2016-11
实施
2016-11-22

At the end of the clause, add the following: The safety aspect is covered by IEC 62052-31:2015.

Electricity metering equipment (a.c.) - Particular requirements - Part 23: Static meters for reactive energy (classes 2 and 3); Amendment 1

ICS
17.220.20;91.140.50
CCS
N22
发布
2016-11
实施
2016-11-22

Electricity metering equipment (a.c.). Particular requirements. Static meters for reactive energy at fundamental frequency (classes 0,5 S, 1 S and 1)

ICS
17.220.20;91.140.50
CCS
发布
2015-01-31
实施
2015-01-31

This part of IEC 62053 applies only to newly manufactured transformer operated static varhour meters of accuracy classes 0@5 S@ and 1 S as well as direct connected static var-hour meters of accuracy class 1@ for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only. This standard uses a conventional definition of reactive energy where the reactive power and energy is calculated from the fundamental frequency components of the currents and voltages only. See Clause 3. NOTE 1 This differs from the approach of IEC 62053-23@ where reactive power and energy is defined only for sinusoidal signals. In this standard reactive power and energy is defined for all periodic signals. Reactive power and energy is defined in this way to achieve proper reproducibility of measurements with meters of different designs. With this definition@ reactive power and energy reflects the generally unnecessary current possible to compensate with capacitors rather than the total unnecessary current. It applies only to static var-hour meters for indoor and outdoor application consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (multi-energy meters)@ or when other functional elements@ like maximum demand indicators@ electronic tariff registers@ time switches@ ripple control receivers@ data communication interfaces@ etc.@ are enclosed in the meter case@ then the relevant standards for these elements also apply. NOTE 2 IEC 61869-2:2012 describes transformers having a measuring range of 0@05 In to Imax for accuracy classes 0@2@ 0@5@ 1 and 2@ and transformers having a measuring range of 0@01 In to Imax for accuracy classes 0@2 S and 0@5 S. As the measuring range of a meter and its associated transformers have to be matched and as only transformers of classes 0@2 S / 0@5 S have the current error and phase displacement characteristics suitable to operate a class 0@5 S / 1 S meter respectively as specified in this standard@ the measuring range of the transformer operated meters will be 0@01 In to Imax. Reactive meters intended to be used together with non-S transformers are@ therefore@ not covered by this standard. It does not apply to: ? var-hour meters where the voltage across the connection terminals exceeds 600 V (lineto- line voltage for meters for polyphase systems); ? portable meters; ? data interfaces to the register of the meter; ? reference meters. The dependability aspect is covered by the standards of the IEC 62059 series.

Electricity metering equipment (a.c.) - Particular requirements - Part 24: Static meters for reactive energy at fundamental frequency (classes 0,5 S, 1 S and 1)

ICS
17.220.20;91.140.50
CCS
F21
发布
2014-06
实施
2016-11-17

Cette partie de la CEI 62056 décrit trois profils pour échange de données par bus en local avec des stations alimentées ou non en énergie. Pour les stations télé-alimentées, le bus fournit l'énergie pour l'échange des données.

Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1 : use of local area networks on twisted pair with carrier signalling

ICS
17.220.20;91.140.50
CCS
N20;P63;F21
发布
2014-05-23
实施
2014-05-23

This Standart specif es the requirements for acceptance os lots of electronic meters of electric power, single phase and polyphase, rates of Class A, B, C and D being applied to new meters repaired.

Acceptance of lots of electronic meters of power - Procedure

ICS
17.220.20;91.140.50
CCS
发布
2011-11-25
实施
2011-12-25

The general acceptance inspection methods specified in this part of IEC 62058 apply to newly manufactured electricity meters produced and supplied in lots of 50 and above. The process described herein can be used for assessment of conformity with the requirements of the Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (MID), using: - Module D, Declaration of conformity to type based on quality assurance of the production process: - Final product inspection and testing; - Module F, Declaration of conformity to type based on product verification: - Verification of conformity with the metrological requirements by examination and testing of every instrument; or - Statistical verification of conformity with the metrological requirements; - Module H1, Declaration of conformity based on full quality assurance plus design examination: - Final product inspection and testing. When the process is used within module F, the inspection methods selected shall meet the requirements specified in 5.3 of Annex F of the MID. See 5.5 below. It is noted, that the requirements of 5.3 of Annex F of the MID do not take into account the switching rules between normal, tightened and reduced inspection. Those switching rules, mandatory with lot-by-lot inspection, when properly applied, ensure adequate protection to the customer against poor quality, and provide incentives to the manufacturer to produce consistently good quality.

Electricity metering equipment (a.c.). Acceptance inspection. Part 11: General acceptance inspection methods

ICS
17.220.20;91.140.50
CCS
N22
发布
2010-09-30
实施
2010-09-30

This part of IEC 62058 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2) delivered in lots in quantities above 50. The method of acceptance of smaller lots should be agreed upon by the manufacturer and the customer. The process described herein is primarily intended for acceptance inspection between the manufacturer and the purchaser. This European standard applies to meters of accuracy classes 0,2 S, 0,5 S, 1 and 2, as well as to meters of class indexes A, B and C. NOTE It can also be used for other purposes, for example to support initial verification.

Electricity metering equipment (a.c.). Acceptance inspection. Part 31: Particular requirements for static meters for active energy (classes 0,2 S, 0,5 S, 1 and 2, and class indexes A, B and C)

ICS
17.220.20;91.140.50
CCS
N22
发布
2010-09-30
实施
2010-09-30

This part of IEC 62058 specifies particular requirements for acceptance inspection of newly manufactured direct connected or transformer operated electromechanical meters for active energy (classes 0,5, 1 and 2) delivered in lots in quantities above 50. The method of acceptance of smaller lots should be agreed upon by the manufacturer and the customer. The process described herein is primarily intended for acceptance inspection between the manufacturer and the purchaser. This European standard applies to meters of accuracy classes 0,5, 1 and 2, as well as to meters of class indexes A and B. NOTE It can also be used for other purposes, for example to support initial verification.

Electricity metering equipment (a.c.). Acceptance inspection. Part 21: Particular requirements for electromechanical meters for active energy (classes 0,5, 1 and 2 and class indexes A and B)

ICS
17.220.20;91.140.50
CCS
N22
发布
2010-09-30
实施
2010-09-30

Sets out the requirements for AMI metering systems intended for time-of-use metering and load management of customers with single-phase and three-phase service connections. Intended that AMI systems will cater for both credit and prepayment metering appl

Advanced Metering Infrastructure (AMI) for residential and commercial customers

ICS
17.220.20;91.140.50
CCS
N22
发布
2008-09-19
实施

Sets out a framework for the integration of standards into a system specification for electricity payment metering systems. Addresses the payment metering system application process, generic processes, generic functions, data elements, system entities an

Electricity metering - Payment systems Part 21: Framework for standardization

ICS
17.220.20;91.140.50
CCS
N22
发布
2006-07-07
实施

Applies to automated meter reading (AMR) in South Africa for large power users as defined by the relevant electricity supply authority. Does not cover the communication system between the AMR meter and the remote master station.

Automated meter reading for large power users

ICS
17.220.20;91.140.50
CCS
N22
发布
2006-02-24
实施

Provides requirements and tests for ripple control receivers.

Electricity metering (ac) - Tariff and load control - Particular requirements for electronic ripple control receivers

ICS
17.220.20;91.140.50
CCS
发布
2006-02-10
实施

Provides requirements and tests for static electricity meters for reactive energy (classes 2 and 3).

Electricity metering equipment (ac) - Particular requirements - Static meters for reactive energy (classes 2 and 3)

ICS
17.220.20;91.140.50
CCS
发布
2006-02-10
实施

Provides type tests for tariff and load control equipment for electricity metering equipment.

Electricity metering equipment (ac) - General requirements, tests and test conditions - Tariff and load control equipment (IEC 62052-21, Ed. 1.0 (2004) MOD)

ICS
17.220.20;91.140.50
CCS
发布
2006-01-19
实施
2006-02-15

Electricity metering equipment. Dependability. Part 11. General concepts

ICS
17.220.20;91.140.50
CCS
发布
2006
实施
2007-01-01

Specifies characteristics of single and polyphase prepayment meters for indoor use, and requirements for meters used in reticulation subsystems that require the meter to have integrated additional protection, safety and control functionality.

Electricity payment systems Part 1: Prepayment meters

ICS
17.220.20;91.140.50
CCS
发布
2005-12-02
实施
2005-12-02



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved