17.240;33.070.01 标准查询与下载



共找到 10 条与 相关的标准,共 1

Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300 MHz - 3 GHz); German version EN 50360:2001 + Cor. :2006 + A1:2012

ICS
17.240;33.070.01
CCS
L06
发布
2013-01
实施
2013-01-01

Basic standard for the in-situ assessment of a broadcast site related to general public exposure to radio frequency electromagnetic fields; German version EN 50554:2010

ICS
17.240;33.070.01
CCS
A58
发布
2011-11-01
实施
2011-11-01

Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

ICS
17.240;33.070.01
CCS
A58
发布
2011-07-31
实施
2011-07-31

This International Standard provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This standard: a) considers RBS which transmit on one or more antennas using one or more frequencies in the range 300 MHz to 6 GHz; b) describes several RF field strength and SAR measurement and computation methodologies with guidance on their applicability to address both the in situ evaluation of installed RBS and laboratory-based evaluations; c) describes how surveyors with a sufficient level of expertise shall establish their specific evaluation procedures appropriate for their evaluation purpose; d) considers the evaluation purposes@ namely: 1) product conformity: to establish that a RBS conforms to a defined set of limit conditions under its intended use; 2) compliance boundary: to establish the compliance boundary or boundaries for a RBS in relation to a defined set of limit conditions; 3) to evaluate RF field strength or SAR values at one or more evaluation locations@ namely: i) evaluation location(s) at arbitrary locations outside the control boundary to provide information for interested parties; ii) evaluation location(s) at the control boundary to confirm validity of control boundary; iii) evaluation location(s) within the control boundary with the specific conditions relevant to investigate an alleged over-exposure incident; e) provides guidance on how to report@ interpret and compare results from different evaluation methodologies and@ where the evaluation purpose requires it@ determine a justified decision against a limit value; f) provides informative guidance on how to evaluate ambient RF field strength levels in the vicinity of a RBS from RF sources other than the RBS under evaluation and at frequencies within and outside the range 300 MHz to 6 GHz; g) provides short descriptions of the informative example case studies to aid the surveyor given in the companion Technical Report IEC 62669 [54].

Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

ICS
17.240;33.070.01
CCS
A58
发布
2011-05
实施
2017-08-29

Case studies supporting IEC 62232 - Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

ICS
17.240;33.070.01
CCS
A58
发布
2011-05
实施

Human exposure to radio frequency fields from hand-held and bodymounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices u

ICS
17.240;33.070.01
CCS
A58
发布
2011-03
实施
2011-03-01

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close

ICS
17.240;33.070.01
CCS
M37;L06
发布
2007-03
实施
2007-03-01

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1 : procedure to determine the specific absorption rate (SAR) for hand-held devices used in clos

ICS
17.240;33.070.01
CCS
M37
发布
2006-11-01
实施
2006-11-20

This International Standard applies to any electromagnetic field (EMF) transmitting device intended to be used with the radiating part of the device in close proximity to the human head and held against the ear, including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3 GHz. The objective of this standard is to specify the measurement method for demonstration of compliance with the specific absorption rate (SAR) limits for such devices.

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximi

ICS
17.240;33.070.01
CCS
L06
发布
2006-09-29
实施
2006-09-29

Applies to any electromagnetic field (EMF) transmitting device intended to be used with the radiating part of the device in close proximity to the human head and held against the ear, including mobile phones, cordless phones, etc. The frequency range is

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close

ICS
17.240;33.070.01
CCS
M04
发布
2005-02
实施
2016-07-08



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号