共找到 79 条与 相关的标准,共 6 页
本文件的要求适用于施工和拆除场所在施工和拆除作业时使用,作业完成后拆除的装置。举例如下: ———新建的建筑物的施工; ———现有建筑物或其一部分工程的维修、改建、扩建或拆除; ———工程施工; ———土方工程; ———类似性质的工程。 本文件的要求适用于固定或可移动装置。这些要求不适用于施工场地的管理场所的装置(例如办公室、衣帽间、会议室、小卖部、餐厅、宿舍、厕所)。704.
Low-voltage electrical installations—Part 7-704: Requirements for special installations or locations—Construction and demolition site installations
Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans
Installations électriques à basse tension
On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment 3:2015) Published by the IET
Guidance Note 1. Selection and Erection of Equipment, 7th edition
110.1.1 The Regulations apply to the design,erection and verification of electrical installations such as those of: (i)residential premises (ii)commercial premises (iii)public premises (iv)industrial premises (v)prefabricated buildings (vi)low voltage generating sets (vii)highway equipment and street furniture (viii)locations containing a bath or shower (ix)swimming pools and other basins (x)rooms and cabins containing sauna healers (xi)construction and demolition sites (xii)agricultural and horticultural premises (xiii)conducting locations with restricted movement (xiv)caravan / camping parks and similar locations (xv)marinas and similar locations (xvi)medical locations (xvii)exhibitions,shows and stands (xviii)solar photovoltaic (PV) power supply systems (xix)outdoor lighting (xx)extra-low voltage lighting (xxi)mobile or transportable units (xxii)caravans and motor caravans (xxiii)electric vehicle charging (xxiv)operating and maintenance gangways (xxv)temporary installations for structures, amusement devices and booths at fairgrounds,amusement parks and circuses including professional stage and broadcast applications (xxvi)floor and ceiling heating systems
Requirements for Electrical Installations. IET Wiring Regulations
Voltage bands for electrical installations of buildings
이 표준은 전기설비의 안전성을 충족하기 위해 보호본딩도체를 포함하여 접지설비 및 보호도체에 대하여 규정한다.
Low-voltage electrical installations — Part 5-54: Selection and erection of electrical equipment — Earthing arrangements and protective conductors
Interpretation Manual No. 15-100 F28 on the December 2002 NF C15-100 standard
Interpretation Manual No. 15-100 F27 on the December 2002 NF C15-100 standard
The particular requirements of this section apply to: (i)circuits intended to supply electric vehicles for charging purposes (ii)protection for safety when feeding back electricity from an electric vehicle into a private or public supply network (under consideration). Inductive charging is not covered. Electrical installations for charging mobility scooters and similar vehicles of 10 A and less are not covered.
Requirements for electrical installations. IET Wiring Regulations. Seventeenth edition
Interpretation Manual No. 15-100 F26 on the December 2002 NF C15-100 standard
Requirements for electrical installations. IET Wiring Regulations. Seventeenth edition
Requirements for electrical installations. IET Wiring Regulations. Seventeenth edition
Low-voltage electrical installations
Guidance Note 1. Selection and Erection of Equipment, 6th edition
Low-voltage electrical installations - Part 7-713: Requirements for special installations or locations - Furniture
Earthing arragngements and equipotential bonding for information technology installations
이 표준에 명시된 특수 요건은 마리나 및 유사장소의 놀이용 수상 기계기구 또는 선상가옥에
Low-voltage electrical installations-Part 7-709:Requirements for special installations or locations-Marinas and similar locations
Surge overvoltages and surge protection in low-voltage a.c. power systems. General basic information
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved