本标准适用于电压3 kV及以上,频率50 Hz及以下的电力系统中运行的户内、户外安装的交流开关设备和控制设备。 除非在于特定类型开关设备和控制设备有关的产品标准中另有规定,本标准适用于所有的高压开关设备和控制设备。

Common specifications for high-voltage switchgear and controlgear standards

ICS
29.130.10;29.130.99
CCS
K43
发布
2011-12-30
实施
2012-05-01

本标准适用于设计安装在户内和户外、端子是封闭和敞开的、额定电压3.6 kV及以上且运行频率l50 Hz及以下的交流隔离开关和接地开关。 I 本标准也适用于这些隔离开关和接地开关的操动机构及其辅助设备。 封闭式开关设备和控制设备中的隔离开关和接地开关的附加要求在GB 3906、GB 7674和IEC 60466中给出。 注:本标准不包括将熔断器作为其一个组件的隔离开关。

High-voltage alternating-current disconnectors and earthing switches

ICS
29.130.10;29.130.99
CCS
K43
发布
2004-05-14
实施
2005-02-01

This part of IEC 62271 applies to AC switchgear and controlgear designed for indoor and/or outdoor installation and for operation at service frequencies up to and including 60 Hz and having rated voltages above 1000 V. This document applies to all high-voltage switchgear and controlgear except as otherwise specified in the relevant IEC standards for the particular type of switchgear and controlgear. NOTE For the use of this document, high-voltage is defined as the rated voltage above 1000 V. However, the term medium voltage is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV.

High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear

ICS
29.130.10;29.130.99
CCS
K43
发布
2017-07-00
实施

High-voltage switchgear and controlgear. Alternating current switches for rated voltages higher than 52 kV

ICS
29.130.10;29.130.99
CCS
K43
发布
2015-03-31
实施
2015-03-31

High-voltage switchgear and controlgear — Part 104: Alternating current switches for rated voltages of 52 kV and above

ICS
29.130.10;29.130.99
CCS
发布
2014-10-27
实施
2014/10/27

This part of IEC 62271 applies to a.c. high-speed earthing switches designed for indoor and outdoor installation and for operation at service frequencies of 50 Hz and 60 Hz on systems having voltages of 550 kV and above. High-speed earthing switches described in this standard are intended to extinguish the secondary arc remaining after clearing faults on transmission lines by the circuit-breakers.

High-voltage switchgear and controlgear - Part 112: Alternating current high-speed earthing switches for secondary arc extinction on transmission lines

ICS
29.130.10;29.130.99
CCS
K43
发布
2013-08
实施
2013-08-08

High-voltage switchgear and controlgear - Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures

ICS
29.130.10;29.130.99
CCS
K43
发布
2013-08
实施

Highvoltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches; Amendment 2

ICS
29.130.10;29.130.99
CCS
K43
发布
2013-02
实施
2013-02-16

High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches

ICS
29.130.10;29.130.99
CCS
K43
发布
2013-02
实施

This part of IEC 62271 applies to alternating current disconnectors and earthing switches@ designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for service frequencies up to and including 60 Hz.It also applies to the operating devices of these disconnectors and earthing switches and their auxiliary equipment.Additional requirements for disconnectors and earthing switches in enclosed switchgear and controlgear are given in IEC 60298@ IEC 60466 and IEC 60517.NOTE Disconnectors in which the fuse forms an integral part are not covered by this standard.

High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches; Amendment 1

ICS
29.130.10;29.130.99
CCS
K43
发布
2011-08
实施
2012-04-29

This part of IEC 62271 applies to a.c. switchgear and controlgear designed for indoor and outdoor installation and for operation at service frequencies up to and including 60Hz on systems having voltages above 1 000 V. This standard applies to all high-voltage switchgear and controlgear except as otherwise specified in the relevant IEC standards for the particular type of switchgear and controlgear. NOTE For the use of this standard, high voltage (see IEV 601-01-27) is the rated voltage above 1 000 V. However, the term medium voltage (see IEV 601-01-28) is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV.

High-voltage switchgear and controlgear.Part 1: Common specifications

ICS
29.130.10;29.130.99
CCS
K43
发布
2011-08
实施

Applicable to three-pole alternating current switches for rated voltages 52 kV and above, that have making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz.

High-voltage switchgear and controlgear Part 104: Alternating current switches for rated voltages of 52 kV and above

ICS
29.130.10;29.130.99
CCS
K43
发布
2009-07-03
实施

This part of IEC 62271 is applicable to three-pole alternating current switches for rated voltages 52 kV and above@ having making and breaking current ratings@ for indoor and outdoor installations@ and for rated frequencies up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment. NOTE 1 Switches for gas insulated switchgear are covered by this standard. NOTE 2 Switches having a disconnecting function and called switch-disconnectors are also covered by IEC 62271-102. NOTE 3 Earthing switches are not covered by this standard. Earthing switches forming an integral part of a switch are covered by IEC 62271-102. The main object of this standard is to establish requirements for switches used in transmission and distribution systems. General-purpose switches for this application are designed to comply with the following service applications: ?C carrying rated normal current continuously; ?C carrying short-circuit currents for a specified time; ?C switching of mainly active loads; ?C switching of no-load transformers; ?C switching of the charging current of unloaded cables@ overhead lines or busbars; ?C switching of closed-loop circuits; ?C making short-circuit currents. A further object of this standard is to establish requirements for limited-purpose and specialpurpose switches used in transmission and distribution systems. Limited-purpose switches shall comply with one or more of the service applications indicated above. Special-purpose switches may comply with one or more of the service applications indicated above and@ in addition@ shall be suitable for one or more of the following applications: ?C switching single capacitor banks; ?C switching back-to-back capacitor banks; ?C switching shunt reactors including secondary or tertiary reactors switched from the primary side of the transformer; ?C applications requiring an increased number of operating cycles; ?C switching under earth fault conditions in non-effectively earthed neutral systems.

High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages of 52 kV and above

ICS
29.130.10;29.130.99
CCS
K43
发布
2009-04
实施
2015-02-09

Applies to compact switchgear assemblies consisting of at least one switching device directly connected to, or sharing components with, one or more other devices such that there is an interaction between the functions of the individual devices. The assem

High-voltage switchgear and controlgear Part 205: Compact switchgear assemblies for rated voltages above 52 kV

ICS
29.130.10;29.130.99
CCS
K43
发布
2008-04-18
实施

Applies to a.c. switchgear and controlgear designed for indoor and outdoor installation and for operation at service frequencies up to and including 60 Hz on systems having voltages above 1 000 V.

High-voltage switchgear and controlgear Part 1: Common specifications

ICS
29.130.10;29.130.99
CCS
发布
2008-03-20
实施
2008-03-20

This part of IEC 62271 applies to compact switchgear assemblies consisting of at least one switching device directly connected to, or sharing components with, one or more other devices such that there is an interaction between the functions of the individual devices. Such assemblies are made up of devices defined in 1.101 and are designed, tested and supplied for use as a single unit. The interaction between devices may be due to proximity, sharing of components or a combination of both. The assemblies may contain components of air insulated switchgear (AIS) only or a combination of AIS and gas insulated switchgear (GIS), so called mixed technology switchgear (MTS) and may be delivered entirely prefabricated or partially assembled. It is not possible to define all potential arrangements of compact switchgear assemblies however four examples are shown for information in Annex A. These compact switchgear assemblies are for indoor and/or outdoor installations in systems having rated voltages above 52 kV and service frequencies of 50 Hz and 60 Hz. This standard covers the influence on performance of the interactions between devices within compact switchgear assemblies and defines ratings and test procedures for these assemblies. IEC 62271-1 is applicable if not stated otherwise. This standard does not apply to switchgear assemblies consisting solely of GIS which are covered by 62271-203.

High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV

ICS
29.130.10;29.130.99
CCS
K43
发布
2008-01
实施
2008-01-17

Contains information and test procedures for type testing of circuit-breakers relevant to short-circuit breaking performance during asymmetrical test duty (T100a) as required by IEC 62271-100 (published in South Africa as an identical adoption under the

High-voltage switchgear and controlgear Part 308: Guide for asymmetrical short-circuit breaking test duty T100a

ICS
29.130.10;29.130.99
CCS
K43
发布
2007-11-02
实施

This technical report contains information and test procedures for type testing of circuit-breakers relevant to short-circuit breaking performance during asymmetrical test duty (T100a) as required by IEC 62271-100. This technical report covers all possib

High-voltage switchgear and controlgear - Part 308: Guide for asymmetrical short-circuit breaking test duty T100a

ICS
29.130.10;29.130.99
CCS
K43
发布
2002-08
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved