33.100.20;33.100.99 标准查询与下载



共找到 14 条与 相关的标准,共 1

이 표준은 현존하는 시스템 레벨의 HEMP 시뮬레이터에 대한 정보와 이 시뮬레이터를 내성

Electromagnetic compatibility(EMC)-Part 4-32:Testing and measurement techniques-High-altitude electromagnetic pulse (HEMP) simulator compendium

ICS
33.100.20;33.100.99
CCS
L06
发布
2012-05-30
实施
2012-05-30

This part of IEC 61000 describes the immunity test levels and related test methods for electrical and electronic equipment and systems exposed to high-altitude electromagnetic pulse (HEMP) environments. It defines ranges of immunity test levels and establishes test procedures. Specifications for test equipment and instrumentation test set-up@ test procedures@ pass/fail criteria@ and test documentation requirements are also defined by this standard. These tests are intended to demonstrate the immunity of electrical and electronic equipment when subjected to HEMP radiated and conducted electromagnetic disturbances. For radiated disturbance immunity tests@ specifications are defined in this standard both for small test facilities and large HEMP simulators.This part of IEC 61000 defines specifications for laboratory immunity tests. On-site tests performed on equipment in the final installation to verify immunity are also specified. These verification tests use the same specifications as laboratory tests@ except for the climatic environmental specifications.The objective of this part of IEC 61000 is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment@ when subjected to HEMP radiated environments and the associated conducted transients on power@ antenna@ and input/output (I/O) signal and control lines.

Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems

ICS
33.100.20;33.100.99
CCS
L06
发布
2012-03-01
实施
2012-05-30

Describes the immunity test levels and related test methods for electrical and electronic equipment and systems exposed to high-altitude electromagnetic pulse (HEMP) environments.

Electromagnetic compatibility (EMC) Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems

ICS
33.100.20;33.100.99
CCS
L06
发布
2006-12-08
实施

Adopts CISPR 16-4-2 which specifies the manner in which measurement uncertainty is to be taken in to account in determining compliance with CISPR limits.

Specification for radio disturbance and immunity measuring apparatus and methods - Uncertainties, statistics and limit modelling - Uncertainty in EMC measurements

ICS
33.100.20;33.100.99
CCS
发布
实施

Adopts CISPR 16-4-4 which specifies the calculation of limits for disturbance field strength and disturbance voltage for the measurement on the test site on the basis of models for the generation of disturbance for radiation coupling respectively for mai

Specification for radio disturbance and immunity measuring apparatus and methods - Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits

ICS
33.100.20;33.100.99
CCS
发布
实施

Adopts CISPR 16-1-2:2004, Ed 1.1 which specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz.

Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances

ICS
33.100.20;33.100.99
CCS
发布
实施

Adopts CISPR 16-4-3, Ed.2 (2004) which specifies recommendations on statistics of disturbance complaints, on the significance of CISPR limits, and specific reports.

Specification for radio disturbance and immunity measuring apparatus and methods - Uncertainties, statistics and limit modelling - Statistical considerations in the determination of EMC compliance of mass-produced products

ICS
33.100.20;33.100.99
CCS
发布
实施

Adopts CISPR 16-1-3,Ed.2 (2004) which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz.

Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power

ICS
33.100.20;33.100.99
CCS
发布
实施

Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Measuring apparatus

ICS
33.100.20;33.100.99
CCS
发布
实施

Specification for radio disturbance and immunity measuring apparatus and methods - Methods of measurement of disturbances and immunity - Conducted disturbance measurements

ICS
33.100.20;33.100.99
CCS
发布
实施

Specification for radio disturbance and immunity measuring apparatus and methods - Methods of measurement of disturbances and immunity - Measurement of disturbance power

ICS
33.100.20;33.100.99
CCS
发布
实施

Specification for radio disturbance and immunity measuring apparatus and methods - Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests

ICS
33.100.20;33.100.99
CCS
发布
实施

Adopts CISPR 16-2-3 which specifies the methods of measurement of radiated disturbance phenomena in the frequency range 9 kHz to 18 GHz.

Specification for radio disturbance and immunity measuring apparatus and methods - Methods of measurement of disturbances and immunity - Radiated disturbance measurements

ICS
33.100.20;33.100.99
CCS
发布
实施

Adopts CISPR 16-1-5 which specifies the requirements for calibration test sites, used to perform antenna calibrations, as well as the test antenna characteristics, calibration site verification procedure and site compliance criteria.

Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Antenna calibration test sites for 30 MHz to 1000 MHz

ICS
33.100.20;33.100.99
CCS
发布
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号