Ethynylestradiol (EE2) ELISA Kit炔雌醇(EE2)试剂盒

上一篇 / 下一篇  2010-09-03 11:51:24/ 个人分类:供求

Ethynylestradiol (EE2) ELISA Kit炔雌醇(EE2)试剂盒

 

EE2 ELISA Kit

  • EE2 monoclonal antibody binds exclusively with EE2 and does not show cross-reaction with other hormones or chemicals with similar structures.
  • The quantitative analysis ranges from 0.05μg/L- 3μg/L(ppb), sensitive enough to detect EE2 in a specimen from river water or blood, etc.
  • With ease of handling, the total time for measurement is only 2.5 hours.
  • The ELISA measurement is highly reproducible; the coefficient of variation (CV) is generally under 10%.
  • The kit, a 96-well microplate format, enables simultaneous measurement of multiple samples at more reasonable cost.

EE2

Ethynylestradiol (EE2), one of main ingredients for contraceptive pill, is suspected as one of the endocrine disrupting chemicals. While GC-MS or LC-MS/MS are generally employed method for quantitative analysis, they require expensive instrumentation as well as complex and time-consuming extraction process with hazardous organic solvent. This test kit detects EE2 in environment or in vitro at a ppt level(ng/L) with the aid of solid phase extraction.


EE2 Standard Curve

 

Samples containing Ethynylestradiol(EE2) within the dynamic range (0.05μg/L- 3μg/L) can be directly applied to assay after filtration. Samples with Ethynylestradiol content below the range must be concentrated with solid phase extraction prior to the ensuing session. Coefficient of variation(CV) is generally under 10% throughout the dynamic range.

 

Pretreatment (Simplified Solid Phase Extraction)
Also see here

 

Adjust the pH of the sample to 5.0 with 1M Acetic acid. Pour sample liquid through a C18 solid-phase cartridge/disk and elute EE2 with dichloromethane.

Dry the sample with nitrogen gas, then adjust MeOH concentration at 10% for measurement.

  • The specific procedure may vary in sample quality.

 

Cross-reactivity Pattern

Compound

Reactivity (%)

Ethynylestradiol(EE2)

100.0

Estrone(E1)

<0.2

2-methoxy E1

<0.2

17β-Estradiol(E2)

<0.2

16-keto-E2

<0.2

E2-17-glucuronide

<0.2

E2-3-glucuronide

<0.2

E2-3-sulfate-17-glucuronide

<0.2

Estriol(E3)

<0.2

16-epi-E3

<0.2

E3-16-glucuronide

<0.2

 

Kit Format

Kit Format

Comment

Microplate

1 plate (96 wells)
& reagents

Needs a microplate reader(450nm)
For multiple and simultaneous measurement

 

如有更多其它试剂产品需求与查询,请及时接洽:info@express-cn.com 或在我公司查询主页客户留言处(http://www.express-cn.com/expressgb/lyb.htm )留下您的查询内容,我们即会在当天为您作出回复。

 

伊普瑞斯科技有限公司

info@express-cn.com  

在线客服:QQ1069267096

         MSNliyuqiu1983@hotmail.com

               cindylee-1981@hotmail.com

联系人:杨先生

总机:010-60206266

传真:010-60206773

www.express-cn.com

 


TAG:

 

评分:0

我来说两句

显示全部

:loveliness::handshake:victory::funk::time::kiss::call::hug::lol:'(:Q:L;P:$:P:o:@:D:(:)

我的栏目

日历

« 2024-05-12  
   1234
567891011
12131415161718
19202122232425
262728293031 

数据统计

  • 访问量: 2101
  • 日志数: 61
  • 建立时间: 2010-08-19
  • 更新时间: 2012-06-06

RSS订阅

Open Toolbar