Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators (Edition 3.1; Consolidated Reprint)

Appareils électromédicaux - Partie 2-4: Exigences particulières pour la sécurité de base et les performances essentielles des défibrillateurs cardiaques (Edition 3.1; Consolidated Reprint)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 60601-2-4-2018 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
60601-2-4-2018
发布日期
2018年02月01日
实施日期
2018年03月02日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
334
适用范围
Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CARDIAC DEFIBRILLATORS@ hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only@ or to ME SYSTEMS only@ the title and content of that clause or subclause will say so. If that is not the case@ the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS@ as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard does not apply to implantable DEFIBRILLATORS@ remote control DEFIBRILLATORS@or separate stand-alone cardiac monitors (which are standardized by IEC 60601-2-27:2011 [2]2). Cardiac monitors which use separate ECG monitoring electrodes are not within the scope of this standard unless they are used as the sole basis for AED rhythm recognition detection or beat detection for synchronized cardioversion. DEFIBRILLATOR electrodes as described in 201.108 can also be used for ECG monitoring; however@ due to the larger electrode area@ the requirements of IEC 60601-2-27 are not applicable for DEFIBRILLATOR ELECTRODES. Defibrillation waveform technology is evolving rapidly. Published studies indicate that the effectiveness of waveforms varies. The choice of a particular waveform including waveshape@ delivered energy@ efficacy@ and safety has been specifically excluded from the scope of this standard. However@ due to the critical importance of the therapeutic waveform@ comments have been added to the rationale which addresses considerations in waveform selection




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号