CAN/ULC 527:2023
火灾报警系统的控制单元和配件

Control Units and Accessories for Fire Alarm Systems


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CAN/ULC 527:2023 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CAN/ULC 527:2023
发布
2023年
发布单位
SCC
当前最新
CAN/ULC 527:2023
 
 
代替标准
13.220.20 13.320
被代替标准
CAN/ULC-S527:2019
适用范围
Scope 1.1 This Standard covers requirements as related to the following: a) Discrete electrical control units and accessories for fire alarm systems including smoke control, releasing, Building System Information Unit (BSIU), and emergency communication systems; b) Electrically- and electronically-operated amplifiers that provide speech communication and distinctive sounds in conjunction with fire protective signaling systems; and c) Commercial stationary and fixed power supplies for fire-protective signaling systems, having input and output ratings of not more than 600 V, direct- and alternating-current, (DC and AC). 1.2 This Standard covers requirements for control units, fire alarm systems and control unit accessories to be employed in ordinary (nonhazardous) indoor and outdoor locations in accordance with the following standards as applicable: a) CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations b) NBC, National Building Code of Canada c) NFPA 12, Standard for Carbon Dioxide Extinguishing Systems d) NFPA 12A, Standard for Halon 1301 Fire Extinguishing Systems e) NFPA 13, Standard for the Installation of Sprinkler Systems f) NFPA 15, Standard for Water Spray Fixed Systems for Fire Protection g) NFPA 16, Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems h) NFPA 17, Standard for Dry Chemical Extinguishing Systems i) NFPA 17A, Standard for Wet Chemical Extinguishing Systems j) NFPA 70, National Electrical Code k) NFPA 72, National Fire Alarm and Signaling Code l) NFPA 92, Standard for Smoke, Control Systems m) NFPA 750, Standard for Water Mist Fire Protection Systems n) NFPA 2001, Standard for Clean Agent Fire Extinguishing Systems o) NFPA 2010, Standard for Aerosol Fire Extinguishing Systems p) ULC-S524, Standard for the Installation of Fire Alarm Systems. 1.3 The products covered by this standard are intended to be used in combination with other appliances and devices to form a commercial fire alarm system. These products provide all monitoring, control, and indicating functions of the system. An installation document(s) provided with the product describes the various products needed to form a fire alarm system and their intended use and installation. subassemblies of complete products manufactured in accordance with previous editions of their respective standards. 1.5 This standard does not cover: a) Manual boxes, automatic fire detectors, manual releasing stations, other initiating devices (e.g. carbon monoxide, and other similar gas sensors) notification appliances not provided as part of the product; and b) In the United States only: Abort stations. 1.6 This Standard does not cover devices such as fans, dampers, motors, etc., which perform smoke control functions. 1.7 The term “product” as used in this Standard refers to all items of equipment covered by the Scope. 1.8 These requirements do not include determination of compliance with: a) In Canada only: The rules and regulations of Innovation, Science and Economic Development Canada. b) In the United States only: The rules and regulations of the Federal Communications Commission (FCC).

CAN/ULC 527:2023相似标准


推荐

Acrel 电气火灾监控系统在黄浦174街坊应用

(6).对探测器控制功能:    通过监控软件操作,可对连接到本设备所有探测器进行远程复位控制。   (7).权限控制功能:    为确保监控系统运行,监控设备软件操作权限分为三级,不同级别的操作员具有不同操作权限。    该系统自投运以来,运行良好,在预防电气火灾方面发挥了重要作用,获得了客户对产品公司认可与信赖。...

多种传感器在储能消防系统锂电池火灾探测报警器中应用

电化学储能舱消防技术方案是防范电化学储能舱火灾关键,主要涵盖电池热失控探测火灾灭火(抑制)两大方面。此方案核心在于构建一套完备热失控探测报警系统,以确保在火灾初起时即能迅速响应,从而有效遏制火灾蔓延。每个储能舱都被视为一个独立防护单元,为其配置了一套区域热失控探测报警系统。这套系统具备超前预警能力,能够在电池模块热失控初期即探测到相关信号。...

剩余电气火灾监控系统在公共建筑中应用

1)剩余电流故障(漏电):故障单元属性(部位、类型)(2)温度报警(超温): 故障单元属性(部位、类型)(3)电流故障(过流): 故障单元属性(部位、类型)监控报警响应时间: ≤30s 监控报警声压级(A计权):≥70dB/1m监控报警光显示:红色LED指示灯,红色光报警信号应保持,直至手动复位 监控报警声信号:可手动消除,当再次有报警信号输入时,能再次启动故障报警项目:(1)监控设备与探测器之间通讯连接线发生断路或短路...

火灾报警控制器与消防联动控制区别与联系

说明:  ①一般情况下,可燃气体探测系统电气火灾监控系统探测器不允许直接接入火灾自动报警系统探测回路,他们探测器需要通过相应控制器将探测信息转达给火灾自动报警系统。  ②消火栓按钮信号是直接传输给消防联动控制,不需要火灾报警控制器转达信息。  2)它可以接收来自于消防联动控制反馈信号故障信号。  ...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号