TS 62743-2012

Radiation protection instrumentation – Electronic counting dosemeters for pulsed fields of ionizing radiation (Edition 1.0)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 TS 62743-2012 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
TS 62743-2012
发布日期
2012年09月01日
实施日期
2012年09月21日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
30
适用范围
This Technical Specification applies to all types of counting dosemeters@ irrespective of the measuring quantity and the type of radiation intended to be measured. It ensures that a single radiation pulse can be correctly measured even if the dosemeter is in the internal state relevant for measuring background or environmental radiation. The characteristics of the dosemeter for repeated pulses is expected to be better than for one single radiation pulse with the same parameters but worse than for continuous radiation@ i.e.@ in between of the characteristics for these two extreme conditions. This Technical Specification does not specify the characteristics of the dosemeter for repeated pulses. The Technical Specification does not apply for those types of counting dosemeters that either ?? do not have an indication or software read-out of the dose rate and the number of pulses counted@ ?? convert the non-pulsed detector signal to counts by a converter@ or ?? use nuclear reactions to generate long and nearly continuous secondary radiation fields which then are measured by the dosemeter using counting techniques instead of measuring the direct radiation pulse. The pulsed radiation source is characterized by the parameters ?C radiation pulse duration@ tpulse@ ?C pulse peak dose rate@ Hpulse@peak@ ?C dose per radiation pulse@ Hpulse. This Technical Specification considers the pulsation of the radiation field as an additional influence quantity like particle energy and direction of radiation incidence. Therefore@ the tests described are additional to all the tests in the respective standards. This simplified model function should not fully describe the dosemeter but it should be valid only ?C maybe with effective values ?C for the tests in the case of a single pulse occurring when the dosemeter is in the internal state relevant for measuring background or environmental radiation@ i.e.@ the dosemeter has not performed any specific parameter adjustment for high dose rate. In this sense this simplified model function uses effective parameters specific for pulsed radiation. This technical specification is applicable to all types of radiation for which a suitable pulsed reference field is available and all other requirements are fulfilled.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号