ASTM F895-1984(2006)
琼脂扩散细胞培养屏蔽细胞毒素的试验方法

Standard Test Method for Agar Diffusion Cell Culture Screening for Cytotoxicity


ASTM F895-1984(2006) 中,可能用到以下耗材

 

Fisher Scientific™ Tissue Path™ IV 组织盒

Fisher Scientific™ Tissue Path™ IV 组织盒

赛默飞实验室耗材产品

 

CULTURE FLASKS Flask Only

CULTURE FLASKS Flask Only

上海安谱科学仪器有限公司

 

CULTURE FLASKS Flask Only

CULTURE FLASKS Flask Only

上海安谱科学仪器有限公司

 

CULTURE FLASKS Flask Only

CULTURE FLASKS Flask Only

上海安谱科学仪器有限公司

 

CULTURE FLASKS Flask Only

CULTURE FLASKS Flask Only

上海安谱科学仪器有限公司

 

MICROSCOPE COVER

MICROSCOPE COVER

上海安谱科学仪器有限公司

 

CULTURE FLASKS Flask Only

CULTURE FLASKS Flask Only

上海安谱科学仪器有限公司

 

CULTURE FLASKS Flask Only

CULTURE FLASKS Flask Only

上海安谱科学仪器有限公司

 

PIPETTING TUBE 10ML

PIPETTING TUBE 10ML

上海安谱科学仪器有限公司

 

PIPETTING TUBE 2 ML

PIPETTING TUBE 2 ML

上海安谱科学仪器有限公司

 

TISSUE GRINDERS/HOMOGENISERS  Plunger - Plain

TISSUE GRINDERS/HOMOGENISERS Plunger - Plain

上海安谱科学仪器有限公司

 

TITAN-MSF CELL. 0.2

TITAN-MSF CELL. 0.2

上海安谱科学仪器有限公司

 

RHEODYNE TEFZEL ROTOR SEAL FOR 7010/7000 /7040 (#A7010-071)

RHEODYNE TEFZEL ROTOR SEAL FOR 7010/7000 /7040 (#A7010-071)

上海安谱科学仪器有限公司

 

Pesticide Method GC Installation 套装 S/SL

Pesticide Method GC Installation 套装 S/SL

上海安谱科学仪器有限公司

 

BOX&COVER,INTERFACE

BOX&COVER,INTERFACE

北京博德恒悦科贸有限公司

 

ASTM127C

ASTM127C

沃尔德姆(香港)有限公司

 

ASTM136C

ASTM136C

沃尔德姆(香港)有限公司

 

ASTM129C

ASTM129C

沃尔德姆(香港)有限公司

 

ASTM137C

ASTM137C

沃尔德姆(香港)有限公司

 

ASTM134C

ASTM134C

沃尔德姆(香港)有限公司

 

TEST TUBES, GRADUATED,  10 ML, 1 GL 18/10

TEST TUBES, GRADUATED, 10 ML, 1 GL 18/10

上海安谱科学仪器有限公司

 

MINISART-PLUS 0.45UM SYRINGE FILTER W/IN TEGRAL PREFILTER

MINISART-PLUS 0.45UM SYRINGE FILTER W/IN TEGRAL PREFILTER

上海安谱科学仪器有限公司

 

BURETTE CLAMPS, WITH ROLLS,   SUITEABLE FOR 1 BURETTE

BURETTE CLAMPS, WITH ROLLS, SUITEABLE FOR 1 BURETTE

上海安谱科学仪器有限公司

 

PK1 MS NOVENT II CONTROL UNIT

PK1 MS NOVENT II CONTROL UNIT

上海安谱科学仪器有限公司

 

FILTER KIT 0.45UM POROSITY PK.30

FILTER KIT 0.45UM POROSITY PK.30

上海安谱科学仪器有限公司

 

FILTERELEMENTKIT,REPLACEMENT

FILTERELEMENTKIT,REPLACEMENT

北京博德恒悦科贸有限公司

 

EVAPORATING DISHES,  WITH SPOUT, DURAN, 170 ML  1 PACK = 10 ST

EVAPORATING DISHES, WITH SPOUT, DURAN, 170 ML 1 PACK = 10 ST

上海安谱科学仪器有限公司

 

接头锁紧螺母后套箍1/16SS,EACH

接头锁紧螺母后套箍1/16SS,EACH

上海安谱科学仪器有限公司

 

Well removing tool

Well removing tool

上海安谱科学仪器有限公司

 

ASTM F895-1984(2006)



标准号
ASTM F895-1984(2006)
发布日期
1984年
实施日期
废止日期
中国标准分类号
C05
国际标准分类号
07.100.10 (Medical microbiology)
发布单位
US-ASTM
适用范围

This test method is useful for assessing the cytotoxic potential of new materials and formulations and as part of a quality control program for established medical devices and components.

This test method assumes that assessment of cytotoxicity provides useful information to aid in predicting the potential clinical applications in humans. Cell culture methods have shown good correlation with animal assays and are frequently more sensitive to cytotoxic agents.

This cell culture test method is suitable for incorporation into specifications and standards for materials to be used in the construction of medical devices that are to be implanted into the human body or placed in contact with tissue fluids or blood on a long-term basis.

Some biomaterials with a history of safe clinical use in medical devices are cytotoxic. This test method does not imply that all biomaterials must pass this assay to be considered safe for clinical use (Practice F 748).

1.1 This test method is appropriate for materials in a variety of shapes and for materials which are not necessarily sterile. This test method would be appropriate in situations where the amount of material is limited. For example, small devices or powders could be placed on the agar and the presence of a zone of inhibition of cell growth could be examined.

1.1.1 This test method is not appropriate for leachables which do not diffuse through agar or agarose.

1.1.2 While the agar layer can act as a cushion to protect the cells from the specimen, there may be materials which are sufficiently heavy to compress the agar and prevent diffusion or to cause mechanical damage to the cells. This test method would not be appropriate for these materials.

1.2 The L-929 cell line was chosen because it has a significant history of use in assays of this type. This is not intended to imply that its use is preferred, only that the L-929 is an established cell line, well-characterized and readily available, that has demonstrated reproducible results in several laboratories.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


ASTM F895-1984(2006) 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号