ASTM C1295-2005
六氟化铀裂变产物释放的γ射线能量辐射的标准试验方法

Standard Test Method for Gamma Energy Emission from Fission Products in Uranium Hexafluoride and Uranyl Nitrate Solution


ASTM C1295-2005 中,可能用到以下耗材

 

血球计算盘Counting,Chamber

血球计算盘Counting,Chamber

无锡德凡仪器有限公司

 

Cover,Sample,Biomate3

Cover,Sample,Biomate3

北京博德恒悦科贸有限公司

 

PK50 LPDNPH S10 (1 PER ZIP BAG)

PK50 LPDNPH S10 (1 PER ZIP BAG)

上海安谱科学仪器有限公司

 

DTGSKBrNicolet380Detector

DTGSKBrNicolet380Detector

北京博德恒悦科贸有限公司

 

Cuvette, semi-micro, PMMA, minimum filling volume 1,5 ml

Cuvette, semi-micro, PMMA, minimum filling volume 1,5 ml

上海安谱科学仪器有限公司

 

Lid, PE-LD, for bucket 5 l

Lid, PE-LD, for bucket 5 l

上海安谱科学仪器有限公司

 

PrevailC185um4.6*7.5mm

PrevailC185um4.6*7.5mm

耐士科技有限公司

 

ASTM C1295-2005



标准号
ASTM C1295-2005
发布日期
2005年
实施日期
废止日期
中国标准分类号
F46
国际标准分类号
27.120.30 (Fissile materials and nuclear fuel tech
发布单位
US-ASTM
适用范围

The gamma-ray emitting fission products in UF6 are identified and quantified using a high-resolution gamma-ray energy analysis system, which includes a high-resolution germanium detector. This test method shall be used to meet the health and safety specifications of C 787, C 788, and C 996 regarding applicable fission products in reprocessed uranium solutions.

1.1 This test method covers the measurement of gamma energy emitted from fission products in uranium hexafluoride (UF6) and uranyl nitrate solution. It is intended to provide a method for demonstrating compliance with UF6 specifications C 787 and C 996 and uranyl nitrate specification C 788.

1.2 The lower limit of detection is 5000 MeV Bq/kg (MeV/kg per second) of uranium and is the square root of the sum of the squares of the individual reporting limits of the nuclides to be measured. The limit of detection was determined on a pure, aged natural uranium (ANU) solution. The value is dependent upon detector efficiency and background.

1.3 The nuclides to be measured are106Ru/ 106Rh, 103Ru,137Cs, 144Ce, 144Pr, 141Ce, 95Zr, 95Nb, and 125Sb. Other gamma energy-emitting fission nuclides present in the spectrum at detectable levels should be identified and quantified as required by the data quality objectives.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


ASTM C1295-2005 中可能用到的仪器设备