ASTM C1255-1993(2005)
用能量色散X射线荧光光谱法分析土壤中铀和钍的标准试验方法

Standard Test Method for Analysis of Uranium and Thorium in Soils by Energy Dispersive X-Ray Fluorescence Spectroscopy


ASTM C1255-1993(2005) 中,可能用到以下仪器设备

 

安东帕Wine monitor 5500/5600在线红酒分析仪

安东帕Wine monitor 5500/5600在线红酒分析仪

安东帕(上海)商贸有限公司

 

ASTM C1255-1993(2005)



标准号
ASTM C1255-1993(2005)
发布日期
1993年
实施日期
废止日期
中国标准分类号
B10
国际标准分类号
27.120.30 (Fissile materials and nuclear fuel tech
发布单位
US-ASTM
适用范围

This test method was developed and the instrument calibrated using ground soils from the site of a nuclear materials plant. This test method can be used to measure the extent of contamination from uranium and thorium in ground soils. Since the detection limit of this technique (nominally 20 x03BC;g per gram) approaches typical background levels for these contaminants, the method can be used as a quick characterization of an on-site area to indicated points of contamination. Then after cleanup, EDXRF may be used to verify the elimination of contamination or other analysis methods (such as colorimetry, fluoremetry, phosphorescence, etc.) can be used if it is necessary to test for cleanup down to a required background level. This test method can also be used for the segregation of soil lots by established contamination levels during on-site construction and excavation.

1.1 This test method covers the energy dispersive X-ray fluorescence (EDXRF) spectrochemical analysis of trace levels of uranium and thorium in soils. Any sample matrix that differs from the general ground soil composition used for calibration (that is, fertilizer or a sample of mostly rock) would have to be calibrated separately to determine the effect of the different matrix composition.

1.2 The analysis is performed after an initial drying and grinding of the sample, and the results are reported on a dry basis. The sample preparation technique used incorporates into the sample any rocks and organic material present in the soil. This test method of sample preparation differs from other techniques that involve tumbling and sieving the sample.

1.3 Linear calibration is performed over a concentration range from 20 to 1000 [mu]g per gram for uranium and thorium.

1.4 The values stated in SI units are to be regarded as the standard. The inch-pound units in parentheses are for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.