DIN EN 1127-2:2008
爆炸性环境.防爆和保护.第2部分:采矿用基本概念和方法论

Explosive atmospheres - Explosion prevention and protection - Part 2: Basic concepts and methodology for mining; German version EN 1127-2:2002 + A1:2008

2008-08

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 DIN EN 1127-2:2008 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
DIN EN 1127-2:2008
发布
2008年
发布单位
德国标准化学会
替代标准
DIN EN 1127-2:2010
当前最新
DIN EN 1127-2:2014-09
 
 
适用范围
This European Standard gives general guidelines for explosion prevention and protection in mining by outlining the basic concepts and methodology for the design and construction of equipment, protective systems and com ponents. This European Standard applies to Group I equipment, protective systems and components intended for use in underground parts of mines and those parts of their surface installations at risk from firedamp and/or flammable dust. This European Standard specifies methods for the identification and assessment of hazardous situations that may lead to explosions and describes the design and construction measures appropriate for the required safety. This is achieved by - hazard identification; - risk assessment; - elimination or minimization of risk; - information for use. The safety of equipment, protective systems, and components can be achieved, as described in EN 292-2:1991, by removal of hazards and/or limiting the risk, i.e. a) by risk reduction by design; b) by safeguarding; c) by information for use; d) by additional precautions. Measures in accordance with a) (prevention) and b) (protection) against explosions are dealt with in clause 6 of this standard, measures according to c) against explosions are dealt with in clause 7 of this standard. Measures in accordance with d) are not described in this European Standard. They are dealt with in clause 6 of EN 292-2:1991. The preventive and protective measures described in this European Standard will not provide the required level of safety unless the equipment, protective systems and components are operated in line with their intended use and are installed and maintained according to the relevant codes of practice or requirements. This standard is applicable to any equipment, protective systems and components intended to be used in potentially explosive atmospheres. These atmospheres can arise from flammable materials processed, used or released by the equipment, protective systems and components or from materials in the vicinity of the equipment, protective systems and components and/or from the materials of construction of the equipment, protective systems and components. As shot firing can release potentially explosive atmospheres, this standard is also applicable to the equipment used for shot firing, apart from the explosives and detonators. This standard is applicable to equipment, protective systems and components at all stages of use. This standard is not applicable to: - medical devices intended for use in a medical environment; - equipment, protective systems and components where the explosion hazard results exclusively from the presence of explosives or unstable chemical substances; - equipment, protective systems and components where the explosion can result from reaction of substances with oxidizing agents other than atmospheric oxygen or by other hazardous reactions or conditions other than atmospheric conditions; - equipment intended for use in domestic and non-commercial environments where explosive atmospheres may only rarely be created and solely as a result of the accidental leakage of fuel gas; - personal protective equipment within the meaning of Directive 89/686/EEC; - the design and construction of systems containing desired, controlled combustion processes, unless they can act as ignition sources in potentially explosive atmospheres; - mines where firedamp and/or flammable dust are not naturally present and surface installations such as coal preparation plants, power plants, coke oven plants etc. in which an explosive atmosphere can be present, but which are not part of a coal mine. These are covered by EN 1127-1:1997.

DIN EN 1127-2:2008相似标准


推荐

朝辉矿用产品顺利取得防爆合格证

GPD系列矿用本安型压力传感器   GUY5矿用本安型液位传感器上海朝辉生产的矿用本安型压力、液位系列传感器经“国家安全生产上海矿用设备检测检验中心”审查检验,确认符合下列标准:GB3836.1-2010《爆炸性环境 1部分:设备 通用要求》GB3836.4-2010《爆炸性环境 4部分:由本质安全型“i”保护的设备》 上海朝辉旨在为客户提供高质量的传感器、变送器、自动化控制产品及完善的工业自动化解决方案...

防爆空调的使用场地主要有

  一、危险场所的危险程度选择防爆空调   根据GB3836.14-2000《爆炸性气体环境用电气设备14部分:危险场所分类》,危险场所可分为0区、1区2区。  (a)0区:爆炸性气体环境连续出现或长期存在的场所。  (b)1区:正常运行时可能出现爆炸性气体环境的地方。  (c)2区:正常运行时,爆炸性气体环境是不可能的,如果发生,也是偶尔发生,只存在很短时间。  ...

防爆空调如何选择及注意事项

  1、根据危险场所的危险程度选择防爆空调。  根据GB3836.14-2000《爆炸性气体环境用电气设备1部分:危险场所分类》,危险场所可分为0区、1区2区。  (a)0区:爆炸性气体环境连续出现或长期存在的场所。  (b)1区:正常运行时可能出现爆炸性气体环境的地方。  (c)2区:正常运行时,爆炸性气体环境是不可能的,如果发生,也是偶尔发生,只存在很短时间。  ...

防爆空调的概述及特点

标准  防爆空调产品必需符合国家相关防爆标准才允许进入市场,国家公布的防爆类产品执行标准有;  GB3836.1-2000 爆炸性气体环境用电气设备 1部分:通用要求  GB3836.2-2000 爆炸性气体环境用电气设备 2部分:隔爆型“d”  GB3836.4-2000 爆炸性气体环境用电气设备 2部分:本安型“ib”  GB3836.9-2006 爆炸性气体环境用电气设备 9部分:浇封型...


谁引用了DIN EN 1127-2:2008 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号