This part of IEC 61400 includes: ~ definition and specification of the quantities to be determined for characterizing the power quality of a grid connected wind turbine; ~ measurement procedures for quantifying the characteristics; ~ procedures for assessing compliance with power quality requirements, including estimation of the power quality expected from the wind turbine type when deployed at a specific site, possibly in groups. The measurement procedures are valid for single wind turbines with a three-phase grid connection. The measurement procedures are valid for any size of wind turbine, though this part of IEC 61400 only requires wind turbine types intended for PCC (Point of Common Coupling) at MV or HV to be tested and characterized as specified in this part of IEC 61400. The measured characteristics are valid for the specific configuration and operational mode of the assessed wind turbine type only. Other configurations, including altered control parameters that cause the wind turbine to behave differently with respect to power quality, require separate assessment. The measurement procedures are designed to be as non-site-specific as possible, so that power quality characteristics measured at for example a test site can be considered valid also at other sites. The procedures for assessing compliance with power quality requirements are valid for wind turbines with PCC at MV or HV in power systems with fixed frequency within +1 Hz, and sufficient active and reactive power regulation capabilities. In other cases, the principles for assessing compliance with power quality requirements may still be used as a guidance. This part of IEC 61400 is for testing of wind turbines, though it contains information that may also be useful for testing of wind farms. NOTE This part of IEC 61400 uses the following terms for system voltage: - Iow voltage (LV) refers to Un ≤ 1 kV; - medium voltage (MV) refers to 1 kV < Un ≤ 35 kV; - high voltage (HV) refers to Un > 35 kV.

IEC 61400-21-2008由国际电工委员会 IX-IEC 发布于 2008-08。

IEC 61400-21-2008 在中国标准分类中归属于: F11 风能,在国际标准分类中归属于: 17.220.20 电和磁量值的测量,27.180 风力发电系统和其他能源。

IEC 61400-21-2008 发布之时,引用了标准

  • IEC 60044-1 Transformateurs de mesure - Partie 1: Transformateurs de courant (Edition 1.2; Edition 1:1996 Consolidated With Amendments 1:2000 and 2:2002)
  • IEC 60044-2 仪表用变压器.第2部分:感应电压变压器
  • IEC 61000-4-7-2002 电磁兼容性(EMC).第4-7部分:试验和测量技术.供电系统及所连设备谐波和谐间波的测量和仪器仪表的通用指南
  • IEC 61400-12-1 *2022-09-05 更新
  • IEC 61800-3-2004 可调速电力传动系统 第3部分:电磁兼容要求和特定试验方法
  • IEC 62008 数字数据采集系统及相关软件的性能特征和校准方法
  • 124 *2014-02-01 更新

* 在 IEC 61400-21-2008 发布之后有更新,请注意新发布标准的变化。

IEC 61400-21-2008的历代版本如下:

  • 2019年05月01日 IEC 61400-21-1-2019 Wind energy generation systems – Part 21-1: Measurement and assessment of electrical characteristics – Wind turbines (Edition 1.0)
  • 2001年12月01日 IEC 61400-21-2001 Aerogenerateurs - Partie 21: Mesurage Et Evaluation Des Caracteristiques De Qualite De Puissance Des Eoliennes Connectees Au Reseau (Edition 1.0)
  • 2008年08月 IEC 61400-21-2008 风力涡轮机.第21部分:并网风力涡轮机的功率质量特性的测量和评估

IEC 61400-21-2008



标准号
IEC 61400-21-2008
发布日期
2008年08月
实施日期
废止日期
中国标准分类号
F11
国际标准分类号
17.220.20;27.180
发布单位
国际电工委员会
引用标准
IEC 60044-1 IEC 60044-2 IEC 60050-161 IEC 60050-415 IEC 61000-4-7-2002 IEC 61000-4-12 IEC 61400-12-1 IEC 61800-3-2004 IEC 62008
被代替标准
IEC 88/317/FDIS-2008 IEC 61400-21-2001
适用范围
This part of IEC 61400 includes: ~ definition and specification of the quantities to be determined for characterizing the power quality of a grid connected wind turbine; ~ measurement procedures for quantifying the characteristics; ~ procedures for assessing compliance with power quality requirements, including estimation of the power quality expected from the wind turbine type when deployed at a specific site, possibly in groups. The measurement procedures are valid for single wind turbines with a three-phase grid connection. The measurement procedures are valid for any size of wind turbine, though this part of IEC 61400 only requires wind turbine types intended for PCC (Point of Common Coupling) at MV or HV to be tested and characterized as specified in this part of IEC 61400. The measured characteristics are valid for the specific configuration and operational mode of the assessed wind turbine type only. Other configurations, including altered control parameters that cause the wind turbine to behave differently with respect to power quality, require separate assessment. The measurement procedures are designed to be as non-site-specific as possible, so that power quality characteristics measured at for example a test site can be considered valid also at other sites. The procedures for assessing compliance with power quality requirements are valid for wind turbines with PCC at MV or HV in power systems with fixed frequency within +1 Hz, and sufficient active and reactive power regulation capabilities. In other cases, the principles for assessing compliance with power quality requirements may still be used as a guidance. This part of IEC 61400 is for testing of wind turbines, though it contains information that may also be useful for testing of wind farms. NOTE This part of IEC 61400 uses the following terms for system voltage: - Iow voltage (LV) refers to Un ≤ 1 kV; - medium voltage (MV) refers to 1 kV < Un ≤ 35 kV; - high voltage (HV) refers to Un > 35 kV.

IEC 61400-21-2008系列标准

IEC 61400-1 (REDLINE + STANDARD)-2019 IEC 61400-1 AMD 1-2010 修改件1.风力涡轮机.第1部分:设计要求 IEC 61400-1 CORR 1-2016 Eoliennes – Partie 1: Exigences de conception (Edition 3.1 Consolidated Reprint) IEC 61400-1 Edition 3.1-2014 风力涡轮机. 第1部分: 设计要求 IEC 61400-1-2019 RLV 风能发电系统第1部分:设计要求 IEC 61400-1-2005/AMD1-2010 修改件1.风力涡轮机.第1部分:设计要求 IEC 61400-1-2019 cor1-2019 风能发电系统第1部分:设计要求 勘误表 IEC 61400-11 AMD 1-2018 风轮发电机系统.第11部分:噪音测量技术.修改件1 IEC 61400-11 Edition 2.1-2006 风轮发电机系统.第11部分:噪音测量技术 IEC 61400-11 Edition 3.1-2018 风轮发电机系统.第11部分:噪音测量技术 IEC 61400-11-2018 IEC 61400-11-2012 amd1-2018 cor1-2019 IEC 61400-11-2012 amd1-2018 cor1-2019 勘误表 IEC 61400-11-2012/AMD1-2018 修改件1.风力涡轮机.第11部分:噪声测量技术 IEC 61400-12-1 (REDLINE + STANDARD)-2017 IEC 61400-12-1 CORR 3-2021 风能发电系统. 第12-1部分: 风力发电涡轮机动力性能测量; 勘误3 IEC 61400-12-1-2022 IEC 61400-12-1-2017 cor1-2019 IEC 61400-12-1-2017 cor1-2019 勘误表 IEC 61400-12-1-2017 cor2-2020 IEC 61400-12-1-2017 cor2-2020 勘误表 IEC 61400-12-6-2022 IEC 61400-12-2 CORR 1-2016 IEC 61400-12-2-2022 IEC 61400-12-3-2022 IEC 61400-12-5-2022 IEC 61400-12-6-2022 IEC 61400-13-2021 IEC 61400-13-2021 IEC 61400-13-2015/AMD1-2021 修改件1.风力涡轮机.第13部分:机械载荷的测量 IEC 61400-2-2013 cor1-2019 风力涡轮机. 第2部分: 小型风力涡轮机 勘误表 IEC 61400-2-2013 cor1-2019 风力涡轮机. 第2部分: 小型风力涡轮机 勘误表 IEC 61400-22-2010 风力涡轮机.第22部分:合格试验和认证 IEC 61400-23-2014 风力涡轮机. 第23部分: 旋转叶片的全尺寸结构试验 IEC 61400-24-2019 IEC 61400-24-2019 IEC 61400-25-1 (REDLINE + STANDARD)-2017 IEC 61400-25-1 REDLINE-2017 IEC 61400-25-1 REDLINE-2017 IEC 61400-25-1-2017 RLV 风能发电系统第25-1部分:风力发电厂监测和控制用通信原理和模型的总体描述 IEC 61400-25-2-2015 风力发电机 - 第25-2部分:风力发电厂监控通信 - 信息模型 IEC 61400-25-3-2015-06 IEC 61400-25-3-2015-06 IEC 61400-25-3-2015-06 IEC 61400-25-3-2015-06 IEC 61400-25-4-2016 风力发电系统.第25-4部分:风力发电厂的监测和控制用通信.绘图到通信轮廓 IEC 61400-25-5-2017 风力发电系统.第25-5部分:风力电厂监控用通信设备.合格试验 IEC 61400-25-6-2016 风力发电系统.第25-6部分:风力电厂监控用通信设备.情况监控用逻辑节点类和数据类 IEC 61400-26-1-2019 风力发电系统.第26-1部分:风力发电系统的可用性 IEC 61400-27-1-2020 IEC 61400-27-1-2020 IEC 61400-27-2-2020 风力发电系统第27-2部分:电气仿真模型模型验证 IEC 61400-3-1-2019 风力发电系统.第3-1部分:固定式海上风力涡轮机的设计要求 IEC 61400-3-2009 风力涡轮机.第3部分:海上风力涡轮机的设计要求 IEC 61400-4-2012 IEC 61400-5-2020 风力发电系统.第5部分:风力涡轮机叶片 IEC 61400-50-1-2022 风能发电系统.第50-1部分:风力测量.气象桅杆、机舱和旋转器安装仪器的应用 IEC 61400-50-2-2022 IEC 61400-50-3:2022 风能发电系统.第50-3部分:风测量用机舱安装的激光雷达的使用 IEC 61400-50-3-2022 风能发电系统.第50-3部分:风测量用机舱安装的激光雷达的使用 IEC 61400-6 AC1-2020 IEC 61400-6 AC1-2020 IEC 61400-6 CORR 1-2020 IEC 61400-6-2020 风能发电系统 - 第6部分:塔和基础设计要求