ASTM D5613-1994(2008)
使用染料示踪剂明渠测量行程时间标准试验方法

Standard Test Method for Open-Channel Measurement of Time of Travel Using Dye Tracers


ASTM D5613-1994(2008) 中,可能用到以下耗材

 

HEADER,6PIN,LOCKING930FLOW

HEADER,6PIN,LOCKING930FLOW

北京博德恒悦科贸有限公司

 

SECURITY,CCS,DISCHARGE4460CCS安全板

SECURITY,CCS,DISCHARGE4460CCS安全板

北京博德恒悦科贸有限公司

 

EYE-WASHING STATION, COMPLETE   *** ENGLISH VERSION ***

EYE-WASHING STATION, COMPLETE *** ENGLISH VERSION ***

上海安谱科学仪器有限公司

 

Lid, PE-LD, for bucket 5 l

Lid, PE-LD, for bucket 5 l

上海安谱科学仪器有限公司

 

ASTM D5613-1994(2008)



标准号
ASTM D5613-1994(2008)
发布日期
1994年
实施日期
废止日期
中国标准分类号
P12
国际标准分类号
17.120.20 (Flow in open channels)
发布单位
US-ASTM
适用范围

Purpose:

This test method covers the use of fluorescent dye tracers in streams to determine the rate that a solute moves along a streamline for a given river reach and the rate at which a solute disperses as it moves downstream.

Accurate measurements of a stream''s velocity and dispersion coefficient that can be determined by a tracer study are important parameters for water-quality models.

Determined in advance to potential spilled or released noxious substances, velocity and dispersion rates are used to predict the time of arrival, passage time, and maximum concentration. Public health officials need this information to decide whether, when, and how long to suspend operations of public water-supply intakes in the reach downstream of a spill.

Assumptions:

This test method assumes that the dye tracer behaves in the same manner as the water in which it is injected. Dispersion and mixing of the tracer in the receiving river occur in all three dimensions of the channel. Longitudinal mixing is unending since boundaries do not exist in this direction.

The tracer response curve at a point downstream from the point of tracer injection can be represented by plotting the tracer concentration against elapsed time since the injection (Fig. 1).

A tracer response curve has four important characteristics: the elapsed time to the response curve''s leading edge; elapsed time to the response curve''s peak concentration; elapsed time to the response curve''s centroid; and elapsed time to response curve trailing edge at 2 % of the peak concentration.

Between two monitoring locations separated by a long stream length, the time-of-travel for individual response curve characteristics is the difference in the elapsed times since injection for that characteristic at the two locations.

The duration or time of passage of a tracer response curve at a particular river location is the difference between the slowest trailing edge elapsed time since injection and the earliest leading edge elapsed time since injection determined in the cross section.

Tracers:

Conservative tracers used to investigate fluid motion are generally extrinsic, artificial, and chemical substances and are usually classified according to the methods of detection used and chemical composition.

Properties to be considered when selecting a tracer for a study include detectability, toxicity, solubility, cost, natural background concentration, and sorption characteristics.

Fluorescent dye tracers such as Rhodamine WT, pontacyl pink, and acid yellow 7 are generally good chemical tracers. Rhodamine WT has the most numerous qualities preferred by many state and federal agencies for open-channel studies.

Other tracers can be used when water-quality or physical conditions are not suitable for the use of fluorescent dyes in a proposed study reach. These include salt-based chemical tracers such as sodium chloride, radioactive tracers such as tritium, and tracers determined with neutron activation analysis such as bromine and lithium (3).

These tracers are considered to be generally conservative and, in terms of this test method, differ primarily in the apparatus required to measure the concentrations in the study reach. Discussions in subsequent sections will be limited to fluorescent dye because of the simplicity of fluorometric analysis.

Different tracers require varied levels of permits before being introduced into the environment. For example, radioactive tracers require permits from the Nuclear Regulatory Commission (NRC) and usually state and local permits. Fluorescent dye tracers do not usually require formal permits for use in a study.