2 m) test ducts are described in the informative Annexes H and I, respectively. The maximum mean flow velocity at the microphone head for which the method is suitable depends on the type of microphone shield used, and is as follows: -- foam ball 15 m/s; -- nose cone 20 m/s; -- sampling tube 40 m/s. Above these values the suppression of turbulent pressure fluctuations by the microphone shield (see 3.9) may be insufficient. It is expected that sound power tests will be conducted in conjunction with airflow performance tests in accordance with ISO 5801. The ducting arrangement will therefore normally incorporate a "star" type flow straightener on the outlet side of the fan which will minimize swirl (see 7.3). Where it is permissible to delete the straightener as, for example, with large fans to installation category C according to ISO 5801:1997, the method is limited to a swirl angle of 15~. (An example of a method for determining the angle of swirl is given in Annex J.) NOTE 2 The installation categories defined in ISO 5801 imply that the fan is either ducted on the outlet side only (category B), on the inlet side only (category C) or on both sides (category D). 1.2 Types of sound source The method described in this International Standard is applicable to a sound source in which a fan is connected to ducts on at least one side. It is also applicable to other fan/attenuator combinations or equipment incorporating fans which can be considered as "black boxes". Examples of fans and other equipment covered by this International Standard are -- ducted centrifugal fans, -- ducted axial flow fans, ducted mixed-flow fans, ducted air-handling units, ducted dust collection units, ducted air-conditioning units, and ducted furnaces. This International Standard is also applicable to other aerodynamic sources such as boxes, dampers and throttle devices provided that a quiet air flow delivered by an auxiliary fan is available and the signal-to-noise ratio of sound pressures to turbulent pressure fluctuations in the test duct is at least 6 dB (see 7.2.1 ). An alternative method to determine the sound power level of the flow-generated noise of such aerodynamic sound sources, which does not require the measurement of sound pressure in a flow environment, is described in ISO 7235. The method was originally devised for the determination of the flow noise level of ducted silencers. The sound power is determined in a reverberation room connected to the test duct via a transition element. In the case of ducted fans with closely coupled attenuators, the signal-to-noise ratio of sound pressures to turbulent pressures may be insufficient when using the in-duct method. Therefore the method described in ISO 7235 is recommended for such fan/attenuator combinations. This International Standard is net applicable to non-ducted fans or equipment. " >

DIN EN ISO 5136-2009
声学,风机或其他空气移动装置辐射入管道中的声功率的测定.管道法(ISO 5136:2003),德文版本 EN ISO 5136:2009

Acoustics - Determination of sound power radiated into a duct by fans and other air-moving devices - In-duct method (ISO 5136:2003); English version of DIN EN ISO 5136:2009-11


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 DIN EN ISO 5136-2009 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
DIN EN ISO 5136-2009
发布日期
2009年11月
实施日期
废止日期
中国标准分类号
Z32
国际标准分类号
17.140.20;23.120
发布单位
DE-DIN
引用标准
ISO 266 ISO 5801-1997 IEC 60651-2001 IEC 60942-1997 IEC 61260
被代替标准
DIN EN ISO 5136-2003 DIN EN ISO 5136/A1-2009
适用范围
1.1 General This International Standard specifies a method for testing ducted fans and other air-moving devices to determine the sound power radiated into an anechoically terminated duct on the inlet and/or outlet side of the equipment. NOTE 1 For the sake of brevity, wherever the term "fan" occurs in the text, it means "fan or other air-moving device". The method is applicable to fans which emit steady, broad-band, narrow-band and discrete-frequency sound and to air temperatures between - 50 ℃ and + 70 ℃. The test duct diameter range is from 0,15 m to 2 m. Test methods for small (d < 0,15 m) and large (d > 2 m) test ducts are described in the informative Annexes H and I, respectively. The maximum mean flow velocity at the microphone head for which the method is suitable depends on the type of microphone shield used, and is as follows: -- foam ball 15 m/s; -- nose cone 20 m/s; -- sampling tube 40 m/s. Above these values the suppression of turbulent pressure fluctuations by the microphone shield (see 3.9) may be insufficient. It is expected that sound power tests will be conducted in conjunction with airflow performance tests in accordance with ISO 5801. The ducting arrangement will therefore normally incorporate a "star" type flow straightener on the outlet side of the fan which will minimize swirl (see 7.3). Where it is permissible to delete the straightener as, for example, with large fans to installation category C according to ISO 5801:1997, the method is limited to a swirl angle of 15~. (An example of a method for determining the angle of swirl is given in Annex J.) NOTE 2 The installation categories defined in ISO 5801 imply that the fan is either ducted on the outlet side only (category B), on the inlet side only (category C) or on both sides (category D). 1.2 Types of sound source The method described in this International Standard is applicable to a sound source in which a fan is connected to ducts on at least one side. It is also applicable to other fan/attenuator combinations or equipment incorporating fans which can be considered as "black boxes". Examples of fans and other equipment covered by this International Standard are -- ducted centrifugal fans, -- ducted axial flow fans, ducted mixed-flow fans, ducted air-handling units, ducted dust collection units, ducted air-conditioning units, and ducted furnaces. This International Standard is also applicable to other aerodynamic sources such as boxes, dampers and throttle devices provided that a quiet air flow delivered by an auxiliary fan is available and the signal-to-noise ratio of sound pressures to turbulent pressure fluctuations in the test duct is at least 6 dB (see 7.2.1 ). An alternative method to determine the sound power level of the flow-generated noise of such aerodynamic sound sources, which does not require the measurement of sound pressure in a flow environment, is described in ISO 7235. The method was originally devised for the determination of the flow noise level of ducted silencers. The sound power is determined in a reverberation room connected to the test duct via a transition element. In the case of ducted fans with closely coupled attenuators, the signal-to-noise ratio of sound pressures to turbulent pressures may be insufficient when using the in-duct method. Therefore the method described in ISO 7235 is recommended for such fan/attenuator combinations. This International Standard is net applicable to non-ducted fans or equipment.