ASTM E1455-2003(2010)
用三原色比色计从直观显示装置中得到比色分析数据的标准实施规程

Standard Practice for Obtaining Colorimetric Data from a Visual Display Unit Using Tristimulus Colorimeters


ASTM E1455-2003(2010) 中,可能用到以下仪器设备

 

SQ Detector 2单级四极杆液质联用仪

SQ Detector 2单级四极杆液质联用仪

沃特世科技(上海)有限公司Waters

 

solariX XR FTICR质谱

solariX XR FTICR质谱

美国布鲁克道尔顿公司(Bruker Daltonic Inc.)

 

奥林巴斯CX22显微镜(CX21升级版)(已停产)

奥林巴斯CX22显微镜(CX21升级版)(已停产)

奥林巴斯(中国)有限公司

 

贝克曼库尔特MoFlo Astrios EQ 超高速流式分选系统

贝克曼库尔特MoFlo Astrios EQ 超高速流式分选系统

贝克曼库尔特商贸(中国)有限公司

 

XR20-W无线型回转轴校准装置

XR20-W无线型回转轴校准装置

雷尼绍(上海)贸易有限公司

 

ASTM E1455-2003(2010)



标准号
ASTM E1455-2003(2010)
发布日期
2003年
实施日期
废止日期
中国标准分类号
A42
发布单位
US-ASTM
适用范围

This practice may be applied when tristimulus colorimeters are used to measure the colors produced on self-luminous video display devices such as CRTs and flat-panel displays, including electroluminescent (EL) panels, field emission displays (FEDs), and back-lit liquid crystal displays (LCDs). This practice is not meant to be a complete description of a procedure to measure the color coordinates of a display. Rather, it provides a method for obtaining more accurate results when certain conditions are met. It may be used by any person engaged in the measurement of color on display devices who has access to the requisite equipment.

This practice defines a class of tristimulus colorimeters that may be said to be compatible with this practice.

1.1 This practice is intended as an aid for improving the accuracy of colorimetric measurements made with tristimulus colorimeters on visual display units, such as cathode ray tubes (CRTs) and self-luminous flat-panel displays. It explains a useful step in the analysis of colorimetric data that takes advantage of the fact that light from such displays consists of an additive mixture of three primary colored lights. However, it is not a complete specification of how such measurements should be made.

1.2 This practice is limited to display devices and colorimetric instruments that meet linearity criteria as defined in the practice. It is not concerned with effects that might cause measurement bias such as temporal or geometric differences between the instrument being optimized and the instrument used for reference.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


ASTM E1455-2003(2010) 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号