JIS C1010-1-2005
测量、控制和实验室用电气设备的安全要求.第1部分:一般要求

Safety requirements for electrical equipment for measurement, control, and laboratory use -- Part 1: General requirements


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:JIS C1010-1-2005 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

JIS C1010-1-2005



标准号
JIS C1010-1-2005
发布日期
2005年03月20日
实施日期
2005年03月22日
废止日期
中国标准分类号
N20
国际标准分类号
13.260;29.020
发布单位
JP-JISC
代替标准
JIS C1010-1-2014
适用范围
1.1.1 Equipment included in scope This Standard specifies general safety require- ments for electrical equipment, any of which may incorporate computing devices, as defined in a) to d) below, when used under the environmental conditions of 1.4. a) Electrical test and measurement equipment This is equipment which by electrical means tests, measures, indicates or records one or more electrical or non-electrical quantities, also non-measuring equipment such as signal generators, measurement standards, power supplies, transducers, transmitters, etc. NOTE: All including and recording electrical measuring instruments (except those excluded in 1.1.2) fall within the scope of this Standard unless they are panel meters designed only for building-in to other equipment. Built-in panel meters are considered to be components and only need to meet the relevant requirements of JIS C 1010, or other standards, as part of the equipment into which they are built. b) Electrical control equipment This is equipment which controls one or more output quantities to specific values, with each value determined by manual setting, by lo- cal or remote programming, or by one or more input variables. c) Electrical laboratory equipment This is equipment which measures, indicates, monitors or analyses substances, or is used to prepare materials, and includes in vitro diagnostic (IVD) equipment. This equipment may also be used in areas other than laboratories, for example self-test IVD equipment may be used in the home. d) Accessories intended for use with the above (for example, sample handling equip- ment).1.1.2 Equipment excluded from scope This Standard does not apply to equipment with the scope of a) JIS B 9960-1 (Safety of machinery -- Electrical equipment of machines -- Part 1 : General requirements) b) JIS C 0364-1 (Electrical insulations of buildings Part I : Scope, object and funda- mental principle) c) JIS C 6065 (Audio, video and similar electronic apparatus -- Safety requirements) d) JIS C 6950 (Safety of information technology equipment, except that specified in 1.1.3) e) JIS C 9335-1 (Household and similar electrical appliances -- Safety -- Part 1 : General requirements) f) JIS T 0601-1 (Medical electrical equipment -- Part i : General requirements for safet~ g) IEC 60439-1 (Low-voltage switchgear and controlgear assemblies- Part I : Type- tested and partially type -tested assemblies) h) IEC 60521 (Class 0.5, I and 2 alternating-current watthour meters) i) IEC 61558 (Power transformers, power supply units and similar) 1.1.3 Computing equipment This Standard applies only to computers, processors, etc. which form part of equipment within the scope of this Standard or are designed for use exclusively with the equipment. NOTE: Computing devices and similar equipment within the scope of JIS C 6950 and conforming to its requirements are considered to be suitable for use with equipment within the scope of this Standard. However, some of the requirements of JIS C 6950 for resistance to moisture and liquids are less stringent than those in this Standard. If HAZARDS from moisture or liquids could affect equipment that conforms to JIS C 6950 and is used with equipment which conforms to this Standard, the instructions for use should specify any additional precautions required.

JIS C1010-1-2005系列标准


谁引用了JIS C1010-1-2005 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号