This part of IEC 60749 is applicable to semiconductor devices (discrete devices and
integrated circuits).
The object of this test is to determine whether the device ignites due to external heating. The
test uses a needle flame, simulating the effect of small flames which may result from fault
conditions within equipment containing the device.
NOTE This test is identical to the test method contained in 1.2 of chapter 4 of IEC 60749 (1996), apart from the
addition of this clause, the addition of titles to clauses 2 and 3 and renumbering.