UL 181B-2005
同柔性风管和风管接头一起使用的密闭系统

UL Standard for Safety Closure Systems for Use with Flexible Air Ducts and Air Connectors Second Edition; Reprint with revisions through and including February 13, 2008.


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 UL 181B-2005 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
UL 181B-2005
发布日期
2005年05月20日
实施日期
废止日期
中国标准分类号
P48
国际标准分类号
91.140.30
发布单位
US-UL
代替标准
UL 181B-2013
适用范围
1.1 These requirements cover pressure-sensitive tapes, mastic systems, and non-metallic mechanical fasteners for use as a part of the closure system of factory-made flexible air ducts or air connectors complying with the Standard for Factory-Made Air Ducts and Air Connectors, UL 181. 1.2 These requirements cover only pressure-sensitive tapes intended for use at the core to fitting attachment and at the outer moisture barrier. When used at the core to fitting attachment, a mechanical fastener shall be installed over the tape. The tape shall be employed at this location such that it does not disrupt the connection of the mechanical fastener. When tape is used at the outer moisture barrier, mechanical fasteners may or may not be employed. 1.3 These requirements cover only mastic systems intended to be used with joints of factory-made flexible non-metallic air ducts or air connectors which employ mechanical fasteners (see 2.4). The joints, without mastics, shall comply with the requirements of the Standard for Factory-Made Air Ducts and Air Connectors, UL 181. 1.4 Mastic closure systems are intended for use as an additional seal at the attachment of the flexible non-metallic air duct cores (or air connectors). The mastic shall be installed uniformly around the mating surface of the fitting collar (i.e. sleeves, elbows, and the like) and in such a manner that it does not disrupt the connection of the mechanical fastener around the core. 1.5 These requirements cover only non-metallic mechanical fasteners intended for use at the core to fitting attachment and at the outer moisture barrier of factory-made flexible non-metallic air ducts or air connectors. When these non-metallic fasteners are used, beaded fittings are required, and a maximum positive operating pressure shall be limited to 6 inch water column (1.5 kPa). Multiple lengths of fasteners may be joined to achieve longer length. This new edition of ANSI/UL 181B includes wording, organizational, miscellaneous editorial revisions, and the following changes in requirements: 1. Deletion of all requirements that pertain to certification issues.2. Clarification of sample selection practices for the Surface Burning Characteristics Tests in Part I - Pressure-Sensitive Tapes and in Part II - Mastic Closure Systems. 3. Revisions to the Temperature Tests in Part I - Pressure-Sensitive Tapes and in Part II - Mastic Closure Systems. 4. Revisions to the Peal Adhesion Test on Stainless Steel and to the Peal Adhesion Test on PVC coated Fabric in Part II - Mastic Closure Systems. 5. Revisions to the Mechanical Strength Test in Part III - Mechanical Fasteners for Use With Flexible Air Ducts. 6. Revisions to several conversions to reflect a statistically significant degree of accuracy for all metric measurements. 1.6 Pressure-sensitive tapes, mastic closure systems, and non-metallic mechanical fasteners are intended for use with flexible air ducts and air connectors installed in accordance with the Standard for the Installation of Air Conditioning and Ventilating Systems, NFPA 90A, and the Standard for the Installation of Warm Air Heating and Air Conditioning Systems, NFPA 90B; and/or Model codes.

谁引用了UL 181B-2005 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号