UL SUBJECT 2755-2011
模块化数据中心的研究概况

UL Standard for Safety Outline of Investigation for Modular Data Centers (Issue 1)


哪些标准引用了UL SUBJECT 2755-2011

 

找不到引用UL SUBJECT 2755-2011 模块化数据中心的研究概况 的标准

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 UL SUBJECT 2755-2011 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
UL SUBJECT 2755-2011
发布日期
2011年10月31日
实施日期
2011年10月31日
废止日期
发布单位
US-UL
适用范围
1.1 This Outline of Investigation covers Modular Data Centers (MDC). The Modular Data Centers covered by these requirements are pre-fabricated units consisting of an outer enclosure housing ITE and various support equipment such as electrical service and distribution equipment, HVAC systems and the like. Some configurations may have the support equipment housed in a separate enclosure. A typical construction may use a standard ISO shipping container or other structure as the outer enclosure, racks or cabinets of ITE, NEC compliant service entrance equipment and power distribution components, power storage such as a UPS and an air or liquid cooling system. 1.2 These factory-built modules incorporate pre-installed materials and equipment which, after installation, may be concealed and may not be accessible for inspection at the final installation site. 1.3 The modular data centers covered by these requirements are intended for fixed installation either indoors or outdoors based on their construction and resistance to environmental conditions. MDCs intended for outdoor use shall be identified with a NEMA environmental class rating. 1.4 These requirements are intended to demonstrate compliance with the National Electrical Code (NEC), NFPA 70 and other national Codes such as Building, Fire, Plumbing, Mechanical, and the like. Where state or local codes differ from the national codes anticipated by these requirements, determining compliance with these codes is the responsibility of the local authority having jurisdiction. 1.5 When these requirements do not cover a specific technology or construction feature, the applicable requirements of the National Codes shall be used. 1.6 This Outline of Investigation assumes that the final installation of the MDC will be performed by qualified service personnel in accordance with the applicable installation instructions, installation practices and national installation codes. These MDCs are intended for installation subject to approval by the Authority Having Jurisdiction.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号