IEC 61010-2-032:2012
测量、控制和试验室用电气设备的安全性要求.第2-032部分:电气测量和试验用手持和用手控制电流感应器的详细要求

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement


IEC 61010-2-032:2012 发布历史

Scope and object This clause of Part 1 is applicable except as follows: Equipment included in scope Replacement: Replace the existing text with the following: This part of IEC 61010 specifies safety requirements for HAND-HELD and hand-manipulated current sensors described below. These current sensors are for measuring@ detecting or injecting current@ or indicating current waveforms on circuits without physically opening the current path of the circuit being measured. They may be stand-alone current sensors or accessories to other equipment or parts of combined equipment (see Figure 101). These include measurement circuits which are part of electrical test and measurement equipment@ laboratory equipment@ or process control equipment. The existence of these current sensors and circuits in equipment requires additional protective means between the current sensor@ the circuit and an OPERATOR. NOTE 1 This part includes also the requirements of Part 2-030. Testing and measuring circuits that are not within the scope of this part are considered to be covered by the requirements of Part 1 or other parts 2s of IEC 61010@ and then will also need to meet the requirements of these other parts with the exception of Part 2-030. Current clamp meters and similar currents sensors that have a primary purpose of measuring voltage on a live MAINS CIRCUIT are also within the scope of Part 2-033. NOTE 2 Some current sensors are also known as current clamps and current probes. Current sensors require hand manipulation before or after a test or measurement@ but do not necessarily need to be HAND-HELD during the test or measurement. NOTE 3 Some current sensors designed for portable use can also be used for fixed installations. The following types of current sensors are covered: a) Type A: a current sensor designed to be applied around or removed from UNINSULATED HAZARDOUS LIVE conductors. Type A current sensors have defined HAND-HELD or handmanipulated parts providing protection against electric shock from the conductor being measured@ and also have protection against short-circuits between wires and busbars during clamping. b) Type B: a current sensor which has protection against short-circuits between wires or busbars during clamping but without defined HAND-HELD or hand-manipulated parts which provide protection against electric shock during clamping. Additional protective means are necessary to avoid electric shock from HAZARDOUS LIVE conductors which cannot be deenergised during application or removal of the current sensor. EXAMPLE 1 Flexible current sensors. c) Type C: a current sensor without protection against short-circuits between wires or busbars during clamping. Type C current sensors are intended to be applied to or removed from UNINSULATED HAZARDOUS LIVE conductors or from non-limited-energy circuit conductors only when they are de-energised. EXAMPLE 2 Split-core transducers. d) Type D: a current sensor designed to be applied around or removed from insulated conductors or from limited-energy circuit conductors. A Type D current sensor does not need protection against short-circuits during clamping and has no defined HAND-HELD or hand-manipulated parts providing protection against electric shock from the conductor being measured. EXAMPLE 3 Current probes for oscilloscopes and earth leakage current detectors. NOTE 4 All current sensors can also be used around insulated conductors. In this case@ HAZARDS are limited to acceptable levels by the insulation of the conductors.

IEC 61010-2-032:2012由国际电工委员会 IX-IEC 发布于 2012-09,并于 2012-09-27 实施。

IEC 61010-2-032:2012 在中国标准分类中归属于: N20 电工仪器、仪表综合,在国际标准分类中归属于: 19.080 电工和电子试验。

IEC 61010-2-032:2012的历代版本如下:

  • 2020年 IEC 61010-2-032:2019/COR1:2020 测量、控制和实验室用电气设备的安全要求第2-032部分:电气试验和测量用手持式和手动电流传感器的特殊要求 勘误表
  • 2019年 IEC 61010-2-032:2019 测量、控制和实验室用电气设备的安全要求第2-032部分:电气试验和测量用手持式和手动电流传感器的特殊要求 勘误表
  • 2012年 IEC 61010-2-032:2012 测量、控制和试验室用电气设备的安全性要求.第2-032部分:电气测量和试验用手持和用手控制电流感应器的详细要求
  • 2002年 IEC 61010-2-032:2002 测量、控制和试验室用电气设备的安全要求.第2-032部分:电气测量和试验用手持和用手控制电流感应器的特殊要求
  • 1994年 IEC 61010-2-032:1994 Règles de sécurité pour appareils électriques de mesurage@ de régulation et ide laboratoire - Partie 2-032: Prescriptions particulières pour pinces amperemétriques tenues à la main pour mesurage et essais électriqiues (Edition 1.0)

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC 61010-2-032:2012 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
IEC 61010-2-032:2012
发布
2012年
发布单位
国际电工委员会
替代标准
IEC 61010-2-032:2019
当前最新
IEC 61010-2-032:2019/COR1:2020
 
 
被代替标准
IEC 66/474/FDIS:2012 IEC 61010-2-032:2002
适用范围
Scope and object This clause of Part 1 is applicable except as follows: Equipment included in scope Replacement: Replace the existing text with the following: This part of IEC 61010 specifies safety requirements for HAND-HELD and hand-manipulated current sensors described below. These current sensors are for measuring@ detecting or injecting current@ or indicating current waveforms on circuits without physically opening the current path of the circuit being measured. They may be stand-alone current sensors or accessories to other equipment or parts of combined equipment (see Figure 101). These include measurement circuits which are part of electrical test and measurement equipment@ laboratory equipment@ or process control equipment. The existence of these current sensors and circuits in equipment requires additional protective means between the current sensor@ the circuit and an OPERATOR. NOTE 1 This part includes also the requirements of Part 2-030. Testing and measuring circuits that are not within the scope of this part are considered to be covered by the requirements of Part 1 or other parts 2s of IEC 61010@ and then will also need to meet the requirements of these other parts with the exception of Part 2-030. Current clamp meters and similar currents sensors that have a primary purpose of measuring voltage on a live MAINS CIRCUIT are also within the scope of Part 2-033. NOTE 2 Some current sensors are also known as current clamps and current probes. Current sensors require hand manipulation before or after a test or measurement@ but do not necessarily need to be HAND-HELD during the test or measurement. NOTE 3 Some current sensors designed for portable use can also be used for fixed installations. The following types of current sensors are covered: a) Type A: a current sensor designed to be applied around or removed from UNINSULATED HAZARDOUS LIVE conductors. Type A current sensors have defined HAND-HELD or handmanipulated parts providing protection against electric shock from the conductor being measured@ and also have protection against short-circuits between wires and busbars during clamping. b) Type B: a current sensor which has protection against short-circuits between wires or busbars during clamping but without defined HAND-HELD or hand-manipulated parts which provide protection against electric shock during clamping. Additional protective means are necessary to avoid electric shock from HAZARDOUS LIVE conductors which cannot be deenergised during application or removal of the current sensor. EXAMPLE 1 Flexible current sensors. c) Type C: a current sensor without protection against short-circuits between wires or busbars during clamping. Type C current sensors are intended to be applied to or removed from UNINSULATED HAZARDOUS LIVE conductors or from non-limited-energy circuit conductors only when they are de-energised. EXAMPLE 2 Split-core transducers. d) Type D: a current sensor designed to be applied around or removed from insulated conductors or from limited-energy circuit conductors. A Type D current sensor does not need protection against short-circuits during clamping and has no defined HAND-HELD or hand-manipulated parts providing protection against electric shock from the conductor being measured. EXAMPLE 3 Current probes for oscilloscopes and earth leakage current detectors. NOTE 4 All current sensors can also be used around insulated conductors. In this case@ HAZARDS are limited to acceptable levels by the insulation of the conductors.

IEC 61010-2-032:2012相似标准


推荐


IEC 61010-2-032:2012系列标准


谁引用了IEC 61010-2-032:2012 更多引用

IEC 62446-1:2018 光伏(PV)系统 测试、文档和维护的要求 第1部分:并网系统 文档、调试测试和检查 IEC 61010-2-034:2017 测量, 控制和实验室使用电气设备的安全要求. 第2-034部分: 绝缘电阻测量设备和耐电强度测试设备的详细要求 IEC 61010-2-030:2017 测量、控制和实验室用电气设备的安全性要求.第2-030部分:具有测试或测量电路设备的特殊要求 IEC 62446-1:2016 光伏(PV)系统.试验、文件和维护要求.第1部分:网格连接系统.文件、试运行测试和检查 BS EN 61000-4-30:2015 电磁兼容性(EMC).第4-30部分:试验和测量技术.电能质量测量法 BS EN 61557-9:2015 不超过1000 V交流和1500 V直流的低压分布系统的电气安全性.防护措施测试,测量和监控设备.第9部分:IT系统中绝缘故障的定位设备 BS EN 61557-16:2015 交流1000V和直流1500V以下低压配电系统的电气安全保护措施的测试、测量或监测设备 用于测试电气设备保护措施有效性的设备,以及 IEC 61557-16:2014 小于等于1000 V交流电以及1500 V直流电低压配电系统的电气安全. 保护措施的测试, 测量或监测设备. 第16部分: 电气设备和/或医疗电气设备保护措施有效性的测试设备 IEC 61784-2:2014 工业通讯网络.配置文件.第2部分:基于ISO/IEC 8802-3标准的实时网络用附加数据总线配置文件 IEC 61557-14:2013 1000 V交流和1500 V直流低压配电系统的电气安全性.保护措施试验、测量或监测用设备.第14部分:测试机械用电气设备安全性的设备