ASTM D6001-05(2012)
地质境调查用直接手压水抽样的标准指南

Standard Guide for Direct-Push Groundwater Sampling for Environmental Site Characterization


标准号
ASTM D6001-05(2012)
发布
2005年
发布单位
美国材料与试验协会
替代标准
ASTM D6001/D6001M-20
当前最新
ASTM D6001/D6001M-20
 
 
引用标准
ASTM D2488 ASTM D4448 ASTM D4700 ASTM D4750 ASTM D5088 ASTM D5092 ASTM D5254 ASTM D5314 ASTM D5434 ASTM D5474 ASTM D5521 ASTM D5730 ASTM D5778 ASTM D5781 ASTM D5782 ASTM D5783 ASTM D5784 ASTM D5875 ASTM D5876 ASTM D5903 ASTM D6067 ASTM D6089 ASTM D6169 ASTM D6235 ASTM D6282 ASTM D6286 ASTM D6452 ASTM D6517 ASTM D653 ASTM D6564 ASTM D6634 ASTM D6724 ASTM D6725 ASTM D6771 ASTM D6911
适用范围
5. Significance and UseTop Bottom

5.1 Direct-push water sampling is an economical method for obtaining discrete groundwater samples without the expense of permanent monitoring well installation (1-6).4 This guide can be used to profile potential groundwater contamination with depth by performing repetitive sampling events. Direct-push water sampling is often used in expedited site characterization (Practice D6235). Soils to be sampled must be permeable to allow filling of the sampler in a relatively short time. The zone to be sampled can be isolated by matching well screen length to obtain discrete samples of thin aquifers. Use of these sampling techniques will result in more detailed characterization of sites containing multiple aquifers. By inserting a protected sampling screen in direct contact with soil and with watertight risers, initial well development (Guide D5521) and purging of wells (Guide D6452) may not be required for the first sampling event. Discrete water sampling, combined with knowledge of location and thickness of target aquifers, may better define conditions in thin multiple aquifers than monitoring wells with screened intervals that can intersect and allow for intercommunication of multiple aquifers (4,6,7,9,13). Direct-push sampling performed without knowledge of the location and thickness of target aquifers can result in sampling of the wrong aquifer or penetration through confining beds.

5.2 For sites that allow surface push of the sampling device, discrete water sampling is often performed in conjunction with the cone penetration test (Test Method D6067) (4-9), which is often used for stratigraphic mapping of aquifers, and to delineate high-permeability zones. In such cases, direct-push water samplin......

分散有机物反射率测量标准

在2011年和2012ICCP会议上,制定了开展实验室间精度研究计划,2012-2013年期间,进行了实验室间工作,并通过ASTM审核程序审查了其统计结果,在2014年形成了ASTM D7708标准。本次研究一套6块岩石样本(表1)是美国地质调查局(USGS)与ICCP协商后,从已经编制并鉴定25块候选岩石中挑选出来(其他表征方法见表2)。...