ASTM D7858-2013
用加压流体萃取和液相色谱/串联质量色谱分析法测定土壤, 淤泥和生物固体中双酚A的标准试验方法

Standard Test Method for Determination of Bisphenol A in Soil, Sludge and Biosolids by Pressurized Fluid Extraction and Analyzed by Liquid Chromatography/Tandem Mass Spectrometry


ASTM D7858-2013 中,可能用到以下仪器

 

Waters ACQUITY UPLC H-CLASS 超高效液相色谱

Waters ACQUITY UPLC H-CLASS 超高效液相色谱

沃特世科技(上海)有限公司

 

Waters ACQUITY UPLC I-Class 超高效液相色谱

Waters ACQUITY UPLC I-Class 超高效液相色谱

沃特世科技(上海)有限公司

 

Waters ACQUITY UPC2 超高效合相色谱

Waters ACQUITY UPC2 超高效合相色谱

沃特世科技(上海)有限公司

 

ACQUITY Arc系统

ACQUITY Arc系统

沃特世科技(上海)有限公司

 

Waters ACQUITY UPLC H-Class Bio

Waters ACQUITY UPLC H-Class Bio

沃特世科技(上海)有限公司

 

ACQUITY UPLC M-Class纳升级至微升级超高效液相色谱

ACQUITY UPLC M-Class纳升级至微升级超高效液相色谱

沃特世科技(上海)有限公司

 

Waters ACQUITY Arc Bio系统

Waters ACQUITY Arc Bio系统

沃特世科技(上海)有限公司

 

二维ACQUITY UPLC系统

二维ACQUITY UPLC系统

沃特世科技(上海)有限公司

 

Nexera Method Scouting System 全方位的方法探索系统

Nexera Method Scouting System 全方位的方法探索系统

岛津企业管理(中国)有限公司/岛津(香港)有限公司

 

Waters PATROL UPLC过程分析仪

Waters PATROL UPLC过程分析仪

沃特世科技(上海)有限公司

 

Waters ACQUITY QDa质谱检测器

Waters ACQUITY QDa质谱检测器

沃特世科技(上海)有限公司

 

Waters SYNAPT G2-Si 质谱

Waters SYNAPT G2-Si 质谱

沃特世科技(上海)有限公司

 

Waters SQ Detector 2 四极杆质谱(SQD2)

Waters SQ Detector 2 四极杆质谱(SQD2)

沃特世科技(上海)有限公司

 

Waters ACQUITY UPLC I-Class/Xevo TQ-S IVD系统

Waters ACQUITY UPLC I-Class/Xevo TQ-S IVD系统

沃特世科技(上海)有限公司

 

Thermo Scientific™ Precision™ 高性能烘箱

Thermo Scientific™ Precision™ 高性能烘箱

赛默飞实验室产品和服务

 

Matrix PlateMate系统

Matrix PlateMate系统

赛默飞实验室产品和服务

 

DairyGuard. Milk Powder Analyzer 奶粉分析仪

DairyGuard. Milk Powder Analyzer 奶粉分析仪

珀金埃尔默企业管理(上海)有限公司

 

PMA 2144 Class II 日射强度计

PMA 2144 Class II 日射强度计

北京欧普特科技有限公司-仪器销售部

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM D7858-2013 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ASTM D7858-2013
发布日期
2013年
实施日期
废止日期
中国标准分类号
P22
国际标准分类号
13.080.10 (Chemical characteristics of soil)
发布单位
US-ASTM
适用范围

5.1x00a0;This is a performance based method, and modifications are allowed to improve performance.

5.1.1x00a0;Due to the rapid development of newer instrumentation and column chemistries, changes to the analysis described in this test method are allowed as long as better or equivalent performance data result. Any modifications shall be documented and performance data generated. The user of the data generated by this test method shall be made aware of these changes and given the performance data demonstrating better or equivalent performance.

5.2x00a0;The first reported synthesis of BPA was by the reaction of phenol with acetone by Zincke.7 BPA has become an important high volume industrial chemical used in the manufacture of polycarbonate plastic and epoxy resins. Polycarbonate plastic and resins are used in numerous products including electrical and electronic equipment, automobiles, sports and safety equipment, reusable food and drink containers, electrical laminates for printed circuit boards, composites, paints, adhesives, dental sealants, protective coatings and many other products.8

5.3x00a0;The environmental source of BPA is predominantly from the decomposition of polycarbonate plastics and resins. BPA is not classified as bio-accumulative by the U.S. Environmental Protection Agency and will biodegrade. BPA has been reported to have adverse effects in aquatic organisms and may be released into environmental waters directly at trace levels through landfill leachate and sewage treatment plant effluents. This method has been investigated for use with soil, sludge, and biosolids.

5.4x00a0;The land application of biosolids has raised concerns over the fate of BPA in the environment and a standard method is needed to monitor concentrations. This method has been investigated for use with various soils.

1.1x00a0;This procedure covers the determination of Bisphenol A (BPA) in soil, sludge, and biosolids. This test method is based upon solvent extraction of a soil matrix by pressurized fluid extraction (PFE). The extract is filtered and analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). BPA is qualitatively and quantitatively determined by this test method.

1.2x00a0;Unitsx2014;The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3x00a0;The Method Detection Limit2 (MDL), electrospray ionization (ESI) mode, and Reporting Range3 for BPA are listed in Table 1.

TABLE 1 Method Detection Limit and Reporting Range



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved