ASTM C1344-1997(2013)
使用普通气源质谱仪对六氟化铀进行同位素分析的标准试验方法

Standard Test Method for Isotopic Analysis of Uranium Hexafluoride by Single-Standard Gas Source Mass Spectrometer Method


ASTM C1344-1997(2013) 中,可能用到以下仪器

 

Spectrum Two 红外光谱仪

Spectrum Two 红外光谱仪

珀金埃尔默企业管理(上海)有限公司

 

Thermo Scientific™ Precision™ 高性能烘箱

Thermo Scientific™ Precision™ 高性能烘箱

赛默飞实验室产品和服务

 

Thermo Scientific™ Precision™ 高性能烘箱

Thermo Scientific™ Precision™ 高性能烘箱

赛默飞实验室产品和服务

 

Thermo Scientific™ Precision™ 高性能烘箱

Thermo Scientific™ Precision™ 高性能烘箱

赛默飞实验室产品和服务

 

Thermo Scientific™ Precision™ 高性能烘箱

Thermo Scientific™ Precision™ 高性能烘箱

赛默飞实验室产品和服务

 

Thermo Scientific™ Precision™ 高性能烘箱

Thermo Scientific™ Precision™ 高性能烘箱

赛默飞实验室产品和服务

 

Precision®紧凑型烘箱

Precision®紧凑型烘箱

北京中科科尔仪器有限公司

 

Precision®高性能烘箱

Precision®高性能烘箱

北京中科科尔仪器有限公司

 

peak 压缩空气Precision Air Compressor

peak 压缩空气Precision Air Compressor

毕克气体仪器贸易(上海)有限公司(Peak Scientific)

 

Thermo Scientific™ Precision™ 低温培养箱

Thermo Scientific™ Precision™ 低温培养箱

赛默飞实验室产品和服务

 

Precision低温培养箱

Precision低温培养箱

赛默飞实验室产品和服务

 

Quick全自动酒品分析仪

Quick全自动酒品分析仪

北京桑翌实验仪器研究所

 

ASTM C1344-1997(2013)



标准号
ASTM C1344-1997(2013)
发布日期
1997年
实施日期
废止日期
国际标准分类号
27.120.30 (Fissile materials and nuclear fuel tech
发布单位
US-ASTM
代替标准
No Replacement
适用范围

5.1x00a0;Uranium hexafluoride is a basic material used to prepare nuclear reactor fuel. To be suitable for this purpose, the material must meet the criteria for isotopic composition. This test method is designed to determine whether the material meets the requirements described in Specifications C787 and C996.

5.2x00a0;ASTM Committee C-26 Safeguards Statement:

5.2.1x00a0;The material (uranium hexafluoride) to which this test method applies is subject to the nuclear safeguards regulations governing its possession and use. The analytical procedure in this test method has been designated as technically acceptable for generating safeguards accountability data.

5.2.2x00a0;When used in conjunction with appropriate certified reference materials (CRMs), this procedure can demonstrate traceability to the national measurement base. However, adherence to this procedure does not automatically guarantee regulatory acceptance of the regulatory safeguards measurements. It remains the sole responsibility of the user of this test method to ensure that its application to safeguards has the approval of the proper regulatory authorities.

1.1x00a0;This test method covers the isotopic analysis of uranium hexafluoride (UF6) and may be used for the entire range of 235U isotopic compositions for which standards are available.

1.2x00a0;This test method is applicable to the determination of the isotopic relationship between two UF6 samples. If the abundance of a specific isotope of one sample (the standard) is known, its abundance in the other can be determined. This test method is flexible in that the number of times a given material is admitted to the ion source may be adjusted to the minimum required for a specified precision level.

1.3x00a0;The sensitivity with which differences between two materials can be detected depends on the measuring system used, but ratio-measuring devices can generally read ratio-of-mol ratio differences as small as 0.0001.

1.4x00a0;The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5x00a0;This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 7.