ASTM F3088-2014
使用离心法量化测量/研究细胞材料粘合剂的相互作用的标准试验方法

Standard Test Method for Use of a Centrifugation Method to Quantify/Study Cell-Material Adhesive Interactions


ASTM F3088-2014 中,可能用到以下仪器设备

 

Luminex 200 液相芯片仪

Luminex 200 液相芯片仪

默克生命科学

 

Guava easyCyte 12系统

Guava easyCyte 12系统

默克生命科学

 

Guava easyCyte 6系统

Guava easyCyte 6系统

默克生命科学

 

Guava easyCyte 6HT系统

Guava easyCyte 6HT系统

默克生命科学

 

guava easyCyte 5系统

guava easyCyte 5系统

默克生命科学

 

Guava easyCyte 5HT系统

Guava easyCyte 5HT系统

默克生命科学

 

默克Millicell ERS-2 电阻仪

默克Millicell ERS-2 电阻仪

默克生命科学

 

Vectra™全自动定量病理学工作站(6片连载型)

Vectra™全自动定量病理学工作站(6片连载型)

珀金埃尔默企业管理(上海)有限公司PerkinElmer

 

Vectra™全自动定量病理学工作站200片连载型

Vectra™全自动定量病理学工作站200片连载型

珀金埃尔默企业管理(上海)有限公司PerkinElmer

 

赛默飞Attune NxT声波聚焦流式细胞仪

赛默飞Attune NxT声波聚焦流式细胞仪

赛默飞 AppliedBiosystems

 

autoMACS Pro 全自动磁性细胞分选仪

autoMACS Pro 全自动磁性细胞分选仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® Tyto 流式细胞分选仪

MACSQuant® Tyto 流式细胞分选仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

美天旎MACSQuant® X高通量流式细胞仪

美天旎MACSQuant® X高通量流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® 流式细胞仪

MACSQuant® 流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

MACSQuant® VYB流式细胞仪

MACSQuant® VYB流式细胞仪

德国美天旎生物技术和贸易(上海)公司Miltenyi Biotec

 

ClonePix 2细胞克隆筛选系统

ClonePix 2细胞克隆筛选系统

美谷分子仪器(上海)有限公司

 

皮升泵LPP01-100(细胞注射器)-LongerPump

皮升泵LPP01-100(细胞注射器)-LongerPump

保定兰格恒流泵有限公司

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM F3088-2014 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ASTM F3088-2014
发布日期
2014年
实施日期
废止日期
国际标准分类号
11.100.99
发布单位
US-ASTM
适用范围

4.1x00a0;This test method describes a cell adhesion method that can be used to provide a detachment percent at a given RCF for cells that have adhered to a substrate, typically for a short time. The information generated by this test method can be used to obtain a semi-quantitative measurement of the adhesion of cells to either an uncoated or pre-coated substrate, when compared to a reference (adherent) cell type on the same substrate. As described in Reyes and Garcia (2003), it is recommended that the 50 % point be used for either ligand concentration or RCF for the most robust measurement of adhesion strength. The adhesion may vary due to changes in the phenotype of the cells or as a result of the specific properties of the surface. The substrate may include tissue culture-treated polystyrene, biomaterials or bioactive surfaces. If the substrate is a hydrogel, care must be taken to avoid cohesive failure in the hydrogel (that is, detached cells have pulled away fragments of gel). The coating may consist of (but is not limited to) the following: natural or synthetic biomaterials, hydrogels, components of extracellular matrix (ECM), ligands, adhesion or bioactive molecules, genes or gene products. Cell concentration is also critical, as use of too high a concentration of cells may result in cells detaching as a sheet, rather than as individual cells. This centrifugation approach, once validated, may be applicable for quality control (QC) and product development. However, until the method is correlated to other measures of cell attachment, the current method should be run in parallel with other known measures of cell adhesion.

4.2x00a0;This test method does not cover test methods to quantitate changes in gene expression, or changes in biomarkers, as identified by immunostaining. This test method additionally does not cover quantitative image analysis techniques. In some cases the change in adhesive properties may reflect on the degree of differentiation or de-differentiation of the cells. However, it is worth noting that adhesive interactions do not necessarily reflect the differentiation state of a particular cell type, although in many instances they do. (See X1.3 for application to the Adhesion of Chondrocytes.)

1.1x00a0;This test method covers a centrifugation cell adhesion assay that can be used to detect changes in adhesive characteristics of cells with passage or treatments. This approach measures the force required to detach cells from a substrate. Adhesion, among many variables, may vary due to changes in the phenotype of the cells.

1.2x00a0;This test method does not cover methods to verify the uniformity of coating of surfaces, nor does it cover methods for characterizing surfaces.

1.3x00a0;The cells may include adult, progenitor or stem cells from any species. The types of cells may include chondrocytes, fibroblasts, osteoblast, islet cells, or other relevant adherent cell types.

1.4x00a0;This test method does not cover methods for isolating or harvesting of cells. This test method does not cover test methods to quantitate changes in gene expression, or changes in biomarker type or concentration, as identified by immunostaining. Nor does this test method cover quantitative image analysis techniques.

1.5x00a0;This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<......